Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

A small calcium beam optical frequency standard with fully-sealed vacuum tube

Haosen Shang, Xiaogang Zhang, Shengnan Zhang, Jingbiao Chen, Haijun Chen

Published Jul 1, 2017• 1 citation
Publisher

Abstract

In this paper a small Calcium beam optical frequency standard utilizing fully-sealed Calcium beam vacuum tube owning smaller size compared with vacuum system with flanges is demonstrated. Adopting the electron shelving detection method, we detect the clock transition 657 nm saturation absorbing spectroscopy whose linewidth is 500 kHz. The instability of this small optical frequency standard is 6.8×10-14at 1 second and 1.8×10-15after 1000 seconds of averaging by comparing with another small Calcium beam optical frequency standard whose reported instability is 3.0×10-14at 1 second. The optical part of the whole system is specially designed for robustness and miniaturization.

DOI
10.1109/fcs.2017.8089017

Related papers

Miniaturized calcium beam optical frequency standard using fully-sealed vacuum tube with 10^−15 instability

Haosen Shang, Xiaogang Zhang, Shengnan Zhang +3 more

. To our knowledge, it's the first time to realize the optical frequency standard using fully-sealed vacuum tube. This work will promote the miniaturization and transportability of the optical clock based on atomic beam.

Optics Express•Nov 20, 2017•43 citations

Application of Electron-Shelving Detection via 423 nm Transition in Calcium-Beam Optical Frequency Standard

Huang Kai-Kai, Zhang Jian-Wei, Deshui Yu +3 more

A new scheme of small compact optical frequency standard based on thermal calcium beam with application of 423 nm shelving detection and sharp-angle velocity selection detection is proposed. Combining these presented techniques, we conclude that a small compact optical frequency standard based on thermal calcium beam will outperform the commercial caesium-beam microwave clock, like the 5071 Cs clock (from HP to Agilent, now Symmetricom company), both in accuracy and stability.

Chinese Physics Letters•Nov 29, 2006•24 citations

Frequency stabilization of 423 nm laser for calcium-beam optical frequency standard

Shengnan Zhang, Xiaogang Zhang, Haosen Shang +2 more

The Ca beam optical frequency standard has the potential to be small optical clock like small Cs beam clock in microwave regime. For improving the signal-to-noise ratio of the clock transition spectroscopy, the electron shelving detection, which uses the fast1S0-1P1423nm transition to detect the narrow1S0-3P1657nm clock transition, was applied for Ca beam optical frequency standard. Therefore the frequency stability of 423 nm laser to some extent determines the performance of the optical frequency standard. In this paper, we stabilize the 423 nm laser frequency to Ca beam signal with side-band locking technique and estimate the preliminary stability of 423 nm laser which is 1.4×10-11at 1 s and 2×10-12at 100 s.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•1 citation

Frequency shift properties of a calcium beam optical clock

Yu Chen, Yabei Su, Jiyang Ma +4 more

The optical frequency transitions with long-lifetime spin triplet states produced by the two valence electrons in the outermost layer of alkaline earth atoms make calcium atom a promising quantum frequency reference. Electron-shelving detection improves the signal-to-noise ratio of the clock transition spectrum, enabling a calcium atomic beam optical frequency standard. This scheme employs the 1S0-1P1 transition at 423 nm to detect the 1S0-3P1 transition at 657 nm, emphasizing the importance of 423 nm laser stability. While the performance of these clocks is well-studied, research on the atomic beam itself is limited. This study investigates frequency shifts in neutral calcium atoms’ 1S0-1P1 transition at 423 nm and their 1S0-3P1 transition at 657 nm. We measure the frequency shift caused by temperature, laser power, and laser alignment, providing insights to optimize the design of the calcium beam’s physical apparatus.

Frontiers in Physics•May 16, 2025•0 citations

Frequency Shift Properties of 1S0-1P1 Transition of a Calcium Beam Optical Clock

Yu Chen, Yabei Su, Lei Han +3 more

The narrow linewidth of1S0-3P1657 nm clock transition makes it a promising quantum frequency reference. In this experiment, the fast1S0-1P1423 nm transition is used to detect the narrow1S0-3P1657 nm clock transition. Therefore, the frequency stability of the 423 nm laser determines the performance of the optical frequency standard. Here we investigate the frequency shift properties of the neutral calcium atoms'1S0-1P1transition at 423 nm. We measure the frequency shift caused by temperature, laser power, and laser beam pointing.

European Frequency and Time Forum•Jun 25, 2024•0 citations

Atomic Beam Distribution in Calcium Beam Optical Clock

Lei Han, Xiaobo Xue, Hui Zhu +3 more

Optical clocks have become a very important tool of investigating the characteristics of atoms and ions, for the state-of-art instability and uncertainty. While optical clocks with long running time is still a critical issue. In order to improve vacuum system design and minimize atomic beam divergence angle in optical beam clock, the resonance fluorescence signal of the atom interacting with laser is adopted to evaluate atomic beam two-dimensional distribution. The laser frequency is stabilized to atomic transition resonance frequency via absorption spectrum method. Meanwhile, the laser beam fixed on a two-dimensional displacement platform is exploited to depict the atomic beam distribution with the resonance fluorescence intensity variation corresponding to each laser incident position. The experiment is carried on the calcium beam optical clock to obtain the preliminary atomic beam distribution.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 15, 2023•0 citations
In this paper a small Calcium beam optical frequency standard utilizing fully-sealed Calcium beam vacuum tube owning smaller size compared with vacuum system with flanges is demonstrated. Adopting the electron shelving detection method, we detect the clock transition 657 nm saturation absorbing spectroscopy whose linewidth is 500 kHz. The instability of this small optical frequency standard is 6.8×10-14at 1 second and 1.8×10-15after 1000 seconds of averaging by comparing with another small Calcium beam optical frequency standard whose reported instability is 3.0×10-14at 1 second. The optical part of the whole system is specially designed for robustness and miniaturization.
The Ca beam optical frequency standard has the potential to be small optical clock like small Cs beam clock in microwave regime. For improving the signal-to-noise ratio of the clock transition spectroscopy, the electron shelving detection, which uses the fast1S0-1P1423nm transition to detect the narrow1S0-3P1657nm clock transition, was applied for Ca beam optical frequency standard. Therefore the frequency stability of 423 nm laser to some extent determines the performance of the optical frequency standard. In this paper, we stabilize the 423 nm laser frequency to Ca beam signal with side-band locking technique and estimate the preliminary stability of 423 nm laser which is 1.4×10-11at 1 s and 2×10-12at 100 s.
The optical frequency transitions with long-lifetime spin triplet states produced by the two valence electrons in the outermost layer of alkaline earth atoms make calcium atom a promising quantum frequency reference. Electron-shelving detection improves the signal-to-noise ratio of the clock transition spectrum, enabling a calcium atomic beam optical frequency standard. This scheme employs the 1S0-1P1 transition at 423 nm to detect the 1S0-3P1 transition at 657 nm, emphasizing the importance of 423 nm laser stability. While the performance of these clocks is well-studied, research on the atomic beam itself is limited. This study investigates frequency shifts in neutral calcium atoms’ 1S0-1P1 transition at 423 nm and their 1S0-3P1 transition at 657 nm. We measure the frequency shift caused by temperature, laser power, and laser alignment, providing insights to optimize the design of the calcium beam’s physical apparatus.
The narrow linewidth of1S0-3P1657 nm clock transition makes it a promising quantum frequency reference. In this experiment, the fast1S0-1P1423 nm transition is used to detect the narrow1S0-3P1657 nm clock transition. Therefore, the frequency stability of the 423 nm laser determines the performance of the optical frequency standard. Here we investigate the frequency shift properties of the neutral calcium atoms'1S0-1P1transition at 423 nm. We measure the frequency shift caused by temperature, laser power, and laser beam pointing.
Optical clocks have become a very important tool of investigating the characteristics of atoms and ions, for the state-of-art instability and uncertainty. While optical clocks with long running time is still a critical issue. In order to improve vacuum system design and minimize atomic beam divergence angle in optical beam clock, the resonance fluorescence signal of the atom interacting with laser is adopted to evaluate atomic beam two-dimensional distribution. The laser frequency is stabilized to atomic transition resonance frequency via absorption spectrum method. Meanwhile, the laser beam fixed on a two-dimensional displacement platform is exploited to depict the atomic beam distribution with the resonance fluorescence intensity variation corresponding to each laser incident position. The experiment is carried on the calcium beam optical clock to obtain the preliminary atomic beam distribution.