Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Japan Society of Applied Physics

Fabrication and evaluation of MKID arrays using YBCO thin films

Keigo Sato, Seiichiro Ariyoshi, Kensuke Nakajima, Atsushi SAITO, Saburo Tanaka

Published Jul 22, 2016• 0 citations
OpenAlex

Related papers

Comparison of Nb-MKID fabrication process and consideration of correlations between Q values and Nb thin films characteristics

Ryota Ito, S. Mima, Chiko Otani +3 more

The Japan Society of Applied Physics•Jul 9, 2020•0 citations

YBCO thin film rf-SQUID using bicrystal junction

Neeraj Khare

Physica C Superconductivity•Feb 1, 1999•2 citations

Evaluation of YBa2Cu3O7-δ-based microwave kinetic inductance detectors with rewound spiral resonators

Kaoru Sato, Seiichiro Ariyoshi, Shun Negishi +4 more

We propose a YBCO-based microwave kinetic inductance detector with rewound strip structure (spiral-MKID) suitable for imaging applications. The superconducting rewound strip acts as a microwave resonator and broadband antenna. A 25-pixel MKID array with a width of 10 μm and slightly varying length of each of the resonators was fabricated on a 10 × 10 mm 2 -MgO substrate. Microwave resonance characteristics of the array were evaluated by measuring one of the scattering-matrix elements, S 21 , using a vector network analyser. The 25 resonance dips were clearly observed around 5 GHz; the frequency spacing between adjacent pixels was 13 MHz, with a standard deviation of 5 MHz. Each resonance frequency was shifted by 170 MHz, owing to the temperature change from 11 K to 50 K. We showed that the YBCO-based spiral-MKIDs with 200 nm-thick films have loaded quality factors of 1,200 at 11 K and 700 at 50 K. We irradiated visible light to a single pixel on the array. The obtained noise equivalent power was on the order of 10 −9 W/Hz 1/2 , while the response time was smaller than 30 ms at 13 K. The responsivity of the array at 70 K was six times larger than that at 13 K.

Journal of Physics Conference Series•Jul 1, 2018•6 citations

Study on line width and space dependence of YBa 2 Cu 3 O 7-δ based MKIDs

Hikaru Mikami, Kangi Hayashi, Takeshi Hizawa +3 more

The Japan Society of Applied Physics•Jan 28, 2020•0 citations

Design and properties of fabricated superconducting microstrip delay lines made with nb, nbn and ybco

Gert K. G. Hohenwarter, Elie K. Track, R.E. Drake +2 more

Abstract We report on design, computer modeling, and experimental evaluation of delay lines fabricated with Nb, NbN, and YBCO superconducting thin films. Constraints resulting from the need to achieve long delays on small substrates and the unavailability of some directly applicable models for simulations will be addressed.

Microwave and Optical Technology Letters•Oct 1, 1991•2 citations

Testing Low-Loss Microstrip Materials with MKIDs for Microwave Applications

John C. Hood, Peter S. Barry, T. Cecil +6 more

arXiv:2202.00115•Journal of Low Temperature Physics•Oct 17, 2022•2 citations
We propose a YBCO-based microwave kinetic inductance detector with rewound strip structure (spiral-MKID) suitable for imaging applications. The superconducting rewound strip acts as a microwave resonator and broadband antenna. A 25-pixel MKID array with a width of 10 μm and slightly varying length of each of the resonators was fabricated on a 10 × 10 mm 2 -MgO substrate. Microwave resonance characteristics of the array were evaluated by measuring one of the scattering-matrix elements, S 21 , using a vector network analyser. The 25 resonance dips were clearly observed around 5 GHz; the frequency spacing between adjacent pixels was 13 MHz, with a standard deviation of 5 MHz. Each resonance frequency was shifted by 170 MHz, owing to the temperature change from 11 K to 50 K. We showed that the YBCO-based spiral-MKIDs with 200 nm-thick films have loaded quality factors of 1,200 at 11 K and 700 at 50 K. We irradiated visible light to a single pixel on the array. The obtained noise equivalent power was on the order of 10 −9 W/Hz 1/2 , while the response time was smaller than 30 ms at 13 K. The responsivity of the array at 70 K was six times larger than that at 13 K.