Optimizing spin ensemble-based AC magnetometry using dynamical decoupling at low temperatures

Demitry Farfurnik, Andrey Jarmola, Dmitry Budker, Nir Bar‐Gill

Published Sep 11, 2017• 0 citations
OpenAlex

Abstract

Ensembles of nitrogen-vacancy (NV) centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure $^{12}$C sample, we find that the Carr-Purcell-Meiboom-Gill (CPMG) protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ($> 500$) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (~10 kHz), for which the experiment time apporaches $T_1$ at a small number of applied DD pulses.

Related papers

Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

Demitry Farfurnik, Andrey Jarmola, Dmitry Budker +1 more

Ensembles of nitrogen-vacancy (NV) centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure $^{12}$C sample, we find that the Carr-Purcell-Meiboom-Gill (CPMG) protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ($> 500$) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (~10 kHz), for which the experiment time apporaches $T_1$ at a small number of applied DD pulses.

•Jan 1, 2018•10 citations

Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

Demitry Farfurnik, A Jarmola, D Budker +1 more

Abstract Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10–250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12 C sample, we find that the Carr-Purcell–Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ( > 500 ) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (∼10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.

arXiv:1709.03368•Journal of Optics•Dec 14, 2017•13 citations

Optimizing a dynamical decoupling protocol for solid-state electronic spin ensembles in diamond

Demitry Farfurnik, Andrey Jarmola, Linh Pham +5 more

We demonstrate significant improvements of the spin coherence time of a dense ensemble of nitrogen-vacancy (NV) centers in diamond through optimized dynamical decoupling (DD). Cooling the sample down to 77 K suppresses longitudinal spin relaxation ${T}_{1}$ effects and DD microwave pulses are used to increase the transverse coherence time ${T}_{2}$ from $\ensuremath{\sim}0.7\phantom{\rule{0.28em}{0ex}}\mathrm{ms}$ up to $\ensuremath{\sim}30\phantom{\rule{0.28em}{0ex}}\mathrm{ms}$. We extend previous work of single-axis (Carr-Purcell-Meiboom-Gill) DD towards the preservation of arbitrary spin states. Following a theoretical and experimental characterization of pulse and detuning errors, we compare the performance of various DD protocols. We identify that the optimal control scheme for preserving an arbitrary spin state is a recursive protocol, the concatenated version of the XY8 pulse sequence. The improved spin coherence might have an immediate impact on improvements of the sensitivities of ac magnetometry. Moreover, the protocol can be used on denser diamond samples to increase coherence times up to NV-NV interaction time scales, a major step towards the creation of quantum collective NV spin states.

arXiv:1505.00636•Physical Review B•Aug 24, 2015•110 citations

Improving the coherence properties of solid-state spin ensembles via optimized dynamical decoupling

Demitry Farfurnik, Andrey Jarmola, Linh Pham +5 more

In this work, we optimize a dynamical decoupling (DD) protocol to improve the spin coherence properties of a dense ensemble of nitrogen-vacancy (NV) centers in diamond. Using liquid nitrogen-based cooling and DD microwave pulses, we increase the transverse coherence time T2 from ∼ 0.7 ms up to ∼ 30 ms. We extend previous work of single-axis (Carr-Purcell-Meiboom-Gill) DD towards the preservation of arbitrary spin states. After performing a detailed analysis of pulse and detuning errors, we compare the performance of various DD protocols. We identify that the concatenated XY8 pulse sequences serves as the optimal control scheme for preserving an arbitrary spin state. Finally, we use the concatenated sequences to demonstrate an immediate improvement of the AC magnetic sensitivity up to a factor of two at 250 kHz. For future work, similar protocols may be used to increase coherence times up to NV-NV interaction time scales, a major step toward the creation of quantum collective NV spin states.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 29, 2016•4 citations

Comparison of dynamical decoupling protocols for a nitrogen-vacancy center in diamond

Zhi‐Hui Wang, G. de Lange, Diego Ristè +2 more

We perform a detailed theoretical-experimental study of the dynamical decoupling (DD) of the nitrogen-vacancy (NV) center in diamond. We investigate the DD sequences applied to suppress the dephasing of the electron spin of the NV center induced by the coupling to a spin bath composed of the substitutional nitrogen atoms. The decoupling efficiency of various DD schemes is studied, including both periodic and aperiodic pulse sequences. For ideal control pulses, we find that the DD protocols with the Carr-Purcell-Meiboom-Gill (CPMG) timing of the pulses provides best performance. We show that, as the number of control pulses increases, the decoupling fidelity scaling differs qualitatively from the predictions of the Magnus expansion, and explain the origin of this difference. In particular, more advanced symmetrized or concatenated protocols do not improve the DD performance. Next, we investigate the impact of the systematic instrumental pulse errors in different periodic and aperiodic pulse sequences. The DD protocols with the single-axis control do not preserve all spin components in the presence of the pulse errors, and the two-axis control is needed. We demonstrate that the two-axis control sequence with the CPMG timing is very robust with respect to the pulse errors. The impact of the pulse errors can be diminished further by symmetrizing this protocol. For all protocols studied here, we present a detailed account of the pulse error parameters which make the strongest impact on the DD performance. In conclusion, we give specific recommendations about choosing the decoupling protocol for the system under investigation.

arXiv:1202.0462•Physical Review B•Apr 11, 2012•129 citations

Optimized Dynamical Decoupling for Spin Ensembles with Large Inhomogeneities

Rajan Paul, Genko Genov, Oliver Schmid +4 more

Spin ensembles show increasing promise for highly efficient quantum sensing and quantum technologies. However, protecting their coherent properties remains a significant challenge. Dynamical decoupling (DD) typically employs a sequence of fast pulses that aim to reduce the effect of unwanted system-environment interactions. However, the performance of the DD sequences typically suffers in spin ensembles, e.g., due to amplitude and frequency inhomogeneities and control errors. In this work, we compare the performance of an extensive number of DD protocols for coherence protection and quantum sensing in an ensemble of negatively charged NV centers under ambient conditions. We identify the optimal approach that uses rapid adiabatic passage pulses, which are robust to amplitude and frequency inhomogeneity, in combination with the variation of their phases. We experimentally demonstrate an improved signal contrast and an order-of-magnitude increase in memory time with the optimal sequence compared to the widely used XY8 with standard rectangular pulses. We also apply our approach for improved sensing of a weak oscillating field. While our particular demonstration is with NV centers in diamond, the optimized protocol is generally applicable to other spin ensembles and to systems with high amplitude and/or frequency inhomogeneities.

quant-pharXiv:2610.39693•Oct 30, 2026•0 citations
Ensembles of nitrogen-vacancy (NV) centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12^{12}12C sample, we find that the Carr-Purcell-Meiboom-Gill (CPMG) protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many (>500> 500>500) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (~10 kHz), for which the experiment time apporaches T1T_1T1​ at a small number of applied DD pulses.
Ensembles of nitrogen-vacancy (NV) centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12^{12}12C sample, we find that the Carr-Purcell-Meiboom-Gill (CPMG) protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many (>500> 500>500) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (~10 kHz), for which the experiment time apporaches T1T_1T1​ at a small number of applied DD pulses.
Abstract Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10–250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12 C sample, we find that the Carr-Purcell–Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ( > 500 ) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (∼10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.
We demonstrate significant improvements of the spin coherence time of a dense ensemble of nitrogen-vacancy (NV) centers in diamond through optimized dynamical decoupling (DD). Cooling the sample down to 77 K suppresses longitudinal spin relaxation T1{T}_{1}T1​ effects and DD microwave pulses are used to increase the transverse coherence time T2{T}_{2}T2​ from $\ensuremath{\sim}0.7\phantom{\rule{0.28em}{0ex}}\mathrm{ms}$ up to $\ensuremath{\sim}30\phantom{\rule{0.28em}{0ex}}\mathrm{ms}$. We extend previous work of single-axis (Carr-Purcell-Meiboom-Gill) DD towards the preservation of arbitrary spin states. Following a theoretical and experimental characterization of pulse and detuning errors, we compare the performance of various DD protocols. We identify that the optimal control scheme for preserving an arbitrary spin state is a recursive protocol, the concatenated version of the XY8 pulse sequence. The improved spin coherence might have an immediate impact on improvements of the sensitivities of ac magnetometry. Moreover, the protocol can be used on denser diamond samples to increase coherence times up to NV-NV interaction time scales, a major step towards the creation of quantum collective NV spin states.
In this work, we optimize a dynamical decoupling (DD) protocol to improve the spin coherence properties of a dense ensemble of nitrogen-vacancy (NV) centers in diamond. Using liquid nitrogen-based cooling and DD microwave pulses, we increase the transverse coherence time T2 from ∼ 0.7 ms up to ∼ 30 ms. We extend previous work of single-axis (Carr-Purcell-Meiboom-Gill) DD towards the preservation of arbitrary spin states. After performing a detailed analysis of pulse and detuning errors, we compare the performance of various DD protocols. We identify that the concatenated XY8 pulse sequences serves as the optimal control scheme for preserving an arbitrary spin state. Finally, we use the concatenated sequences to demonstrate an immediate improvement of the AC magnetic sensitivity up to a factor of two at 250 kHz. For future work, similar protocols may be used to increase coherence times up to NV-NV interaction time scales, a major step toward the creation of quantum collective NV spin states.
We perform a detailed theoretical-experimental study of the dynamical decoupling (DD) of the nitrogen-vacancy (NV) center in diamond. We investigate the DD sequences applied to suppress the dephasing of the electron spin of the NV center induced by the coupling to a spin bath composed of the substitutional nitrogen atoms. The decoupling efficiency of various DD schemes is studied, including both periodic and aperiodic pulse sequences. For ideal control pulses, we find that the DD protocols with the Carr-Purcell-Meiboom-Gill (CPMG) timing of the pulses provides best performance. We show that, as the number of control pulses increases, the decoupling fidelity scaling differs qualitatively from the predictions of the Magnus expansion, and explain the origin of this difference. In particular, more advanced symmetrized or concatenated protocols do not improve the DD performance. Next, we investigate the impact of the systematic instrumental pulse errors in different periodic and aperiodic pulse sequences. The DD protocols with the single-axis control do not preserve all spin components in the presence of the pulse errors, and the two-axis control is needed. We demonstrate that the two-axis control sequence with the CPMG timing is very robust with respect to the pulse errors. The impact of the pulse errors can be diminished further by symmetrizing this protocol. For all protocols studied here, we present a detailed account of the pulse error parameters which make the strongest impact on the DD performance. In conclusion, we give specific recommendations about choosing the decoupling protocol for the system under investigation.
Spin ensembles show increasing promise for highly efficient quantum sensing and quantum technologies. However, protecting their coherent properties remains a significant challenge. Dynamical decoupling (DD) typically employs a sequence of fast pulses that aim to reduce the effect of unwanted system-environment interactions. However, the performance of the DD sequences typically suffers in spin ensembles, e.g., due to amplitude and frequency inhomogeneities and control errors. In this work, we compare the performance of an extensive number of DD protocols for coherence protection and quantum sensing in an ensemble of negatively charged NV centers under ambient conditions. We identify the optimal approach that uses rapid adiabatic passage pulses, which are robust to amplitude and frequency inhomogeneity, in combination with the variation of their phases. We experimentally demonstrate an improved signal contrast and an order-of-magnitude increase in memory time with the optimal sequence compared to the widely used XY8 with standard rectangular pulses. We also apply our approach for improved sensing of a weak oscillating field. While our particular demonstration is with NV centers in diamond, the optimized protocol is generally applicable to other spin ensembles and to systems with high amplitude and/or frequency inhomogeneities.