Frontiers in Optics

Sub-nano-Tesla, Shield-less, Field Compensation-Free Optical Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou, Eric Y. Zhu, E. W. Hagley

Published Jan 1, 2017• 0 citations
Publisher

Abstract

We report an optical wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without magnetic field shielding, zero-field compensation, or RF-modulation spectroscopy.
DOI
10.1364/fio.2017.fw2e.1

Related papers

Sub-nano-Tesla, Shield-less, Field Compensation-Free Inelastic Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou +2 more

We report an inelastic-wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without employing magnetic field shielding, field compensation, and RF-modulation spectroscopy.

Conference on Lasers and Electro-Optics•Jan 1, 2018•0 citations

Sub-nano-Tesla, Shield-less, Field Compensation-Free Inelastic Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou +2 more

We report an inelastic-wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without employing magnetic field shielding, field compensation, and RF-modulation spectroscopy.

•Jan 1, 2018•0 citations

Sub-nano-Tesla, Shield-less, Field Compensation-Free Inelastic Wave Mixing Magnetometry for Bio-magnetism

L. Deng, Yvonne Y. Li, Feng Lei Zhou +2 more

We report an inelastic-wave-mixing-enhanced Zeeman-coherence atomic magnetometry scheme that results in sub-nT magnetic field detection at human-body temperatures without employing magnetic field shielding, field compensation, and RF-modulation spectroscopy.

OSA Advanced Photonics Congress•Jan 1, 2018•0 citations

Nanotesla-level, shield-less, field-compensation-free, wave-mixing-enhanced body-temperature atomic magnetometry for biomagnetism

Feng Lei Zhou, Eric Y. Zhu, Yvonne Y. Li +2 more

We report an optical inelastic-wave-mixing-enhanced atomic magnetometry technique that results in nT-level magnetic field detection at temperatures compatible with the human body without magnetic shielding, zero-field compensation, or high-frequency modulated phase-locking spectroscopy. Using Gaussian magnetic pulses that mimic the transient magnetic field produced by an action potential on a frog's nerve, we demonstrate more than 300,000-fold (550-fold) enhancement of magneto-optical rotation signal power spectral-density (power amplitude) over the conventional single-beam $Λ-$scheme atomic magnetometry method. This new technique may bring possibilities for extremely sensitive magnetic field imaging of biological systems accessible via an optical fiber in clinical environments.

arXiv:1804.08194•Apr 22, 2018•1 citation

Symmetry-Breaking Zeeman-Coherence Parametric Wave Mixing Magnetometry

Feng Lei Zhou, Chengjie Zhu, E. W. Hagley +1 more

The nonlinear magneto-optical effect has significantly impacted modern society with prolific applications ranging from precision mapping of the Earth's magnetic field to bio-magnetic sensing. Pioneering works on collisional spin-exchange effects have led to ultra-high magnetic field detection sensitivities at the level of $fT/\sqrt{Hz}$ using a single linearly-polarized probe light field. Here we demonstrate a nonlinear Zeeman-coherence parametric wave-mixing optical-atomic magnetometer using room temperature rubidium vapor that results in more than a three-order-of-magnitude optical signal-to-noise ratio (SNR) enhancement for extremely weak magnetic field sensing. This unprecedented enhancement was achieved with nearly a two-order-of-magnitude reduction in laser power while preserving the sensitivity of the widely-used single-probe beam optical-atomic magnetometry method. This new method opens a myriad of applications ranging from bio-magnetic imaging to precision measurement of the magnetic properties of subatomic particles.

arXiv:1609.00431•Sep 2, 2016•1 citation

Giant Enhancement in Nonlinear Optical-Atomic Magnetometry

Lu Deng, Feng Lei Zhou, E. W. Hagley

We demonstrate a cross-polarization wave-mixing nonlinear atomic magnetometer that results in >500X optical signal signal-to-noise ratio enhancement with perfect field sensitivity preservation and significant reduction of laser power, opening a myriad of applications in bio-magnetism.

Frontiers in Optics•Jan 1, 2016•0 citations
We report an optical inelastic-wave-mixing-enhanced atomic magnetometry technique that results in nT-level magnetic field detection at temperatures compatible with the human body without magnetic shielding, zero-field compensation, or high-frequency modulated phase-locking spectroscopy. Using Gaussian magnetic pulses that mimic the transient magnetic field produced by an action potential on a frog's nerve, we demonstrate more than 300,000-fold (550-fold) enhancement of magneto-optical rotation signal power spectral-density (power amplitude) over the conventional single-beam Λ−Λ-Λ−scheme atomic magnetometry method. This new technique may bring possibilities for extremely sensitive magnetic field imaging of biological systems accessible via an optical fiber in clinical environments.
The nonlinear magneto-optical effect has significantly impacted modern society with prolific applications ranging from precision mapping of the Earth's magnetic field to bio-magnetic sensing. Pioneering works on collisional spin-exchange effects have led to ultra-high magnetic field detection sensitivities at the level of fT/HzfT/\sqrt{Hz}fT/Hz​ using a single linearly-polarized probe light field. Here we demonstrate a nonlinear Zeeman-coherence parametric wave-mixing optical-atomic magnetometer using room temperature rubidium vapor that results in more than a three-order-of-magnitude optical signal-to-noise ratio (SNR) enhancement for extremely weak magnetic field sensing. This unprecedented enhancement was achieved with nearly a two-order-of-magnitude reduction in laser power while preserving the sensitivity of the widely-used single-probe beam optical-atomic magnetometry method. This new method opens a myriad of applications ranging from bio-magnetic imaging to precision measurement of the magnetic properties of subatomic particles.