Journal of the Optical Society of America A

Photon-number uncertainty in a superconducting transition-edge sensor beyond resolved-photon-number determination | NIST

Zachary H. Levine, Boris L. Glebov, Alan L. Migdall, Thomas Gerrits, Brice Calkins, Adriana E. Lita, Sae Woo Nam

Published Sep 10, 2014• 0 citations
OpenAlex

Related papers

Extending single-photon optimized superconducting transition edge sensors beyond the single-photon counting regime | NIST

Thomas Gerrits, Brice Calkins, Nathan A. Tomlin +4 more

•Sep 19, 2011•0 citations

Superconducting Multiplexers for Transition-Edge Sensors | NIST

K. D. Irwin, James A. Beall, Joern Beyer +8 more

•Jun 1, 2003•2 citations

Photon-Number-Resolving Transition-Edge Sensors for the Metrology of Quantum Light Sources

M. Schmidt, Martin von Helversen, Marco López +6 more

Journal of Low Temperature Physics•May 10, 2018•83 citations

High-Performance Ti Transition-Edge Sensor-based Photon-Number Resolving Detectors

Peizhan Li, Jiaqiang Zhong, Wen Zhang +8 more

Journal of Low Temperature Physics•Nov 23, 2023•14 citations

High Speed Photon Number Resolving Detector with Titanium Transition Edge Sensor

Daiji Fukuda, Go Fujii, Akio Yoshizawa +5 more

Journal of Low Temperature Physics•Jan 17, 2008•35 citations

Photon-number uncertainty in a superconducting transition edge sensor beyond resolved-photon-number determination

Zachary H. Levine, Boris L. Glebov, Alan L. Migdall +4 more

As part of an effort to extend fundamental single-photon measurements into the macroscopic regime, we explore how best to assign photon-number uncertainties to output waveforms of a superconducting transition edge sensor and how those assignments change over that extended dynamic range. Three methods are used. At the lowest photon numbers (up to 20 photons), the widths of histogram peaks of individual waveforms are used to determine the uncertainty. From 100 to 1000 photons, mean waveforms are used to create a photon-number scale. The photon-number uncertainty of the detector in this range is given by the excess of the total variance of the photon number obtained from individual waveforms on this scale beyond the shot noise due to the source. In the midrange (from 10 to 100 photons), including a range where the two other methods do not produce definitive results, we fit waveforms to several adjacent mean waveforms to estimate the photon-number uncertainty. A one-standard-deviation uncertainty in photon number of no more than ±1 is found for pulses of up to 100 photons.

Journal of the Optical Society of America B•Sep 10, 2014•12 citations
As part of an effort to extend fundamental single-photon measurements into the macroscopic regime, we explore how best to assign photon-number uncertainties to output waveforms of a superconducting transition edge sensor and how those assignments change over that extended dynamic range. Three methods are used. At the lowest photon numbers (up to 20 photons), the widths of histogram peaks of individual waveforms are used to determine the uncertainty. From 100 to 1000 photons, mean waveforms are used to create a photon-number scale. The photon-number uncertainty of the detector in this range is given by the excess of the total variance of the photon number obtained from individual waveforms on this scale beyond the shot noise due to the source. In the midrange (from 10 to 100 photons), including a range where the two other methods do not produce definitive results, we fit waveforms to several adjacent mean waveforms to estimate the photon-number uncertainty. A one-standard-deviation uncertainty in photon number of no more than ±1 is found for pulses of up to 100 photons.