Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Single Atom Detection and Non-Classical Photon Correlations

Dennis Heine

Published Jan 1, 2008• 0 citations
Publisher

Abstract

In this thesis a reliable and robust single atom detector is presented, characterised and applied to measure the fluorescence emission of single atoms. The detector consists of a tapered single mode excitation fibre and a multi mode detection fibre, both integrated on an atom chip. Single neutral 87Rb atoms propagating freely in a 1D magnetic guide can be detected with an efficiency of 66% due to highly selective excitation and matched detection region. The detector allows to identify the statistical distribution of the atoms, which, for the current experiments, was proven to be Poissonian. Non-classical correlations in the photon emission from a single atom have been measured, showing a perfect photon anti-bunching. Rabi oscillations of the correlation function have been observed and proven to be in excellent agreement with theoretical expectations. The detector presented here is conceptionally much simpler than comparable integrated detectors employing cavity assisted detection and can be produced by using only commercially available lithographic techniques. With this detector single atom sensitivity is reached without the need for cavity assisted detection or localization of the atoms.

DOI
10.11588/heidok.00008588

Related papers

A single-atom detector integrated on an atom chip: fabrication, characterization and application

Dennis Heine, Wolfgang Rohringer, D Fischer +7 more

We describe a robust and reliable fluorescence detector for single atoms that is fully integrated on an atom chip. The detector allows spectrally and spatially selective detection of atoms, reaching a single-atom detection efficiency of 66%. It consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multi-mode fiber to collect the fluorescence. The fibers are mounted in lithographically defined holding structures on the atom chip. Neutral 87 Rb atoms propagating freely in a magnetic guide are detected and the noise of their fluorescence emission is analyzed. The variance of the photon distribution allows us to determine the number of detected photons per atom and from there the atom detection efficiency. The second-order intensity correlation function of the fluorescence shows near-perfect photon anti-bunching and signs of damped Rabi oscillations. With simple improvements, one can increase the detection efficiency to 95%.

arXiv:1002.1573•New Journal of Physics•Sep 9, 2010•32 citations

Simple integrated single-atom detector

Marco Wilzbach, Dennis Heine, S. Groth +4 more

We present a reliable and robust integrated fluorescence detector capable of detecting single atoms. The detector consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multimode fiber to collect the fluorescence. Both are mounted in lithographically defined SU-8 holding structures on an atom chip. 87Rb atoms propagating freely in a magnetic guide are detected with an efficiency of up to 66%, and a signal-to-noise ratio in excess of 100 is obtained for short integration times.

arXiv:0801.3255•Optics Letters•Jan 23, 2009•27 citations

Integrated atom detector: Single atoms and photon statistics

Dennis Heine, Marco Wilzbach, Thomas Raub +2 more

We demonstrate a robust fiber-optics-based fluorescence detector, fully integrated on an atom chip, which detects single atoms propagating in a guide with 66% efficiency. We characterize the detector performance and the atom flux by analyzing the photon statistics. Near-perfect photon antibunching proves that single atoms are detected, and allows us to study the second-order intensity correlation function of the fluorescence over three orders of magnitude in atomic density.

arXiv:0903.3896•Physical Review A•Feb 27, 2009•20 citations

Single atom detection on an atom chip with integrated optics

Marco Wilzbach

The subject of this thesis is the miniaturization and integration of detectors for the detection of single rubidium atoms on an atom chip. For this purpose three different detectors were developed for atom detection by absorption or fluorescence: i) A fluorescence detector was realized by mounting a tapered lensed fiber perpendicular to a collection fiber. ii) An absorption detector was built by placing a multi-mode fiber in-line with a tapered lensed fiber. iii) A tunable cavity detector was built from two single mode fibers mounted on the chip surface. To mount the detectors on the planar surface of the atom chip retaining structures by means of lithographical techniques were developed. Those structures allow a very accurate and stable passive fiber alignment. To test the individual detectors an atomic ensemble of thermal rubidium atoms was prepared in a magneto-optical trap. Then the atoms were transferred into magnetic micro-traps of the atom chip and were guided to one of the detectors. Each integrated detector has been evaluated by several characterization measurements. With the fluorescence detector the highest single atom detection efficiency of 54\\% was attained. Thereby it was possible to perform quantitative measurements for the magnetically guided atoms on a single atom level and to study fundamental properties of the confined atoms.

•Jan 1, 2007•0 citations

Detecting Neutral Atoms on an Atom Chip

Marco Wilzbach, Albrecht Haase, Michael Schwarz +8 more

Detecting single atoms (qubits) is a key requirement for implementing quantum information processing on an atom chip. The detector should ideally be integrated on the chip. Here we present and compare different methods capable of detecting neutral atoms on an atom chip. After a short introduction to fluorescence and absorption detection we discuss cavity enhanced detection of single atoms. In particular we concentrate on optical fiber based detectors such as fiber cavities and tapered fiber dipole traps. We discuss the various constraints in building such detectors in detail along with the current implementations on atom chips. Results from experimental tests of fiber integration are also described. In addition we present a pilot experiment for atom detection using a concentric cavity to verify the required scaling.

•Aug 18, 2006•11 citations

Detecting neutral atoms on an atom chip

M. Wilzbach, A. Haase, M. Schwarz +8 more

Abstract Detecting single atoms (qubits) is a key requirement for implementing quantum information processing on an atom chip. The detector should ideally be integrated on the chip. Here we present and compare different methods capable of detecting neutral atoms on an atom chip. After a short introduction to fluorescence and absorption detection we discuss cavity enhanced detection of single atoms. In particular we concentrate on optical fiber based detectors such as fiber cavities and tapered fiber dipole traps. We discuss the various constraints in building such detectors in detail along with the current implementations on atom chips. Results from experimental tests of fiber integration are also described. In addition we present a pilot experiment for atom detection using a concentric cavity to verify the required scaling.

arXiv:physics/0608189•Fortschritte der Physik•Aug 1, 2006•7 citations
In this thesis a reliable and robust single atom detector is presented, characterised and applied to measure the fluorescence emission of single atoms. The detector consists of a tapered single mode excitation fibre and a multi mode detection fibre, both integrated on an atom chip. Single neutral 87Rb atoms propagating freely in a 1D magnetic guide can be detected with an efficiency of 66% due to highly selective excitation and matched detection region. The detector allows to identify the statistical distribution of the atoms, which, for the current experiments, was proven to be Poissonian. Non-classical correlations in the photon emission from a single atom have been measured, showing a perfect photon anti-bunching. Rabi oscillations of the correlation function have been observed and proven to be in excellent agreement with theoretical expectations. The detector presented here is conceptionally much simpler than comparable integrated detectors employing cavity assisted detection and can be produced by using only commercially available lithographic techniques. With this detector single atom sensitivity is reached without the need for cavity assisted detection or localization of the atoms.
We describe a robust and reliable fluorescence detector for single atoms that is fully integrated on an atom chip. The detector allows spectrally and spatially selective detection of atoms, reaching a single-atom detection efficiency of 66%. It consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multi-mode fiber to collect the fluorescence. The fibers are mounted in lithographically defined holding structures on the atom chip. Neutral 87 Rb atoms propagating freely in a magnetic guide are detected and the noise of their fluorescence emission is analyzed. The variance of the photon distribution allows us to determine the number of detected photons per atom and from there the atom detection efficiency. The second-order intensity correlation function of the fluorescence shows near-perfect photon anti-bunching and signs of damped Rabi oscillations. With simple improvements, one can increase the detection efficiency to 95%.
We present a reliable and robust integrated fluorescence detector capable of detecting single atoms. The detector consists of a tapered lensed single-mode fiber for precise delivery of excitation light and a multimode fiber to collect the fluorescence. Both are mounted in lithographically defined SU-8 holding structures on an atom chip. 87Rb atoms propagating freely in a magnetic guide are detected with an efficiency of up to 66%, and a signal-to-noise ratio in excess of 100 is obtained for short integration times.
The subject of this thesis is the miniaturization and integration of detectors for the detection of single rubidium atoms on an atom chip. For this purpose three different detectors were developed for atom detection by absorption or fluorescence: i) A fluorescence detector was realized by mounting a tapered lensed fiber perpendicular to a collection fiber. ii) An absorption detector was built by placing a multi-mode fiber in-line with a tapered lensed fiber. iii) A tunable cavity detector was built from two single mode fibers mounted on the chip surface. To mount the detectors on the planar surface of the atom chip retaining structures by means of lithographical techniques were developed. Those structures allow a very accurate and stable passive fiber alignment. To test the individual detectors an atomic ensemble of thermal rubidium atoms was prepared in a magneto-optical trap. Then the atoms were transferred into magnetic micro-traps of the atom chip and were guided to one of the detectors. Each integrated detector has been evaluated by several characterization measurements. With the fluorescence detector the highest single atom detection efficiency of 54\\% was attained. Thereby it was possible to perform quantitative measurements for the magnetically guided atoms on a single atom level and to study fundamental properties of the confined atoms.
Detecting single atoms (qubits) is a key requirement for implementing quantum information processing on an atom chip. The detector should ideally be integrated on the chip. Here we present and compare different methods capable of detecting neutral atoms on an atom chip. After a short introduction to fluorescence and absorption detection we discuss cavity enhanced detection of single atoms. In particular we concentrate on optical fiber based detectors such as fiber cavities and tapered fiber dipole traps. We discuss the various constraints in building such detectors in detail along with the current implementations on atom chips. Results from experimental tests of fiber integration are also described. In addition we present a pilot experiment for atom detection using a concentric cavity to verify the required scaling.
Abstract Detecting single atoms (qubits) is a key requirement for implementing quantum information processing on an atom chip. The detector should ideally be integrated on the chip. Here we present and compare different methods capable of detecting neutral atoms on an atom chip. After a short introduction to fluorescence and absorption detection we discuss cavity enhanced detection of single atoms. In particular we concentrate on optical fiber based detectors such as fiber cavities and tapered fiber dipole traps. We discuss the various constraints in building such detectors in detail along with the current implementations on atom chips. Results from experimental tests of fiber integration are also described. In addition we present a pilot experiment for atom detection using a concentric cavity to verify the required scaling.