Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Simulating a Quantum Phase Transition with a Surface Electrode Ion Trap

Bichen Zhang, Omid Khosravani, Gang Shu, Kenneth R. Brown

Published Jun 6, 2017• 0 citations
OpenAlex

Related papers

Onset of a quantum phase transition with a trapped ion quantum simulator

Rajibul Islam, E.E. Edwards, Kihwan Kim +8 more

arXiv:1103.2400•Nature Communications•Jul 5, 2011•411 citations

Creating equally spaced linear ion string in a surface-electrode trap by feedback control

Yi Xie, Xinfang Zhang, Bao-Quan Ou +5 more

A feedback control method for producing an equidistant ion string in a surface-electrode ion trap has been experimentally demonstrated. This method features three advantages: (i) The optimal voltage can be constrained within the specified reachable range. (ii) The height of trapped ions from the trap surface can be maintained at the same value when strings with different number of ions or with different ion spacings are to be trapped. (iii) This method is resistant to a stray electric field near the trap. By this method, the asymmetry of the ion string caused by a stray field is minimized. The robustness of trapping a variable number of ions at the same potential and the dependency of the axial frequency on the number of ions are also investigated experimentally. This work would be a practical method to create a linear ion string with a large number of ions and may find applications in large-scale quantum computing, quantum simulation, and phase transition studies utilizing homogeneous ion strings.

Physical Review A•Mar 31, 2017•17 citations

Exploring structural phase transitions of ion crystals

L.-L. Yan, Wei Wan, Liang Chen +4 more

Phase transitions have been a research focus in many-body physics over past decades. Cold ions, under strong Coulomb repulsion, provide a repealing paradigm of exploring phase transitions in stable confinement by electromagnetic field. We demonstrate various conformations of up to sixteen laser-cooled (40)Ca(+) ion crystals in a home-built surface-electrode trap, where besides the usually mentioned structural phase transition from the linear to the zigzag, two additional phase transitions to more complicated two-dimensional configurations are identified. The experimental observation agrees well with the numerical simulation. Heating due to micromotion of the ions is analysed by comparison of the numerical simulation with the experimental observation. Our investigation implies very rich and complicated many-body behaviour in the trapped-ion systems and provides effective mechanism for further exploring quantum phase transitions and quantum information processing with ultracold trapped ions.

Scientific Reports•Feb 11, 2016•44 citations

Quantum phase transitions in an ion trap

Milburn

Quantum Electronics and Laser Science Conference•Jan 1, 2000•0 citations

Quantum Phase Transitions in a Linear Ion Trap

Gerard J Milburn, Paul M. Alsing

arXiv:quant-ph/0003001•Springer eBooks•Nov 16, 2007•4 citations

Design optimization and precision requirements of an endcap ion trap for single-ion optical clock applications

Chaowei Wang, Shaoyang Dai, Yani Zuo +1 more

Ion traps serve as the venue for confining ions and exciting ionic transitions in ion optical clocks, where the geometric dimensions of the electrodes within the ion trap directly impact the performance metrics of the ion optical clocks. In this study, the finite element analysis method was employed to simulate the relationship between the electric field distribution and the dimensions of the electrodes in an endcap ion trap. The simulation data were subjected to curve fitting, with trap depth and potential anharmonicity utilized as the primary evaluation criteria for optimizing ion trap design. The results indicate that the ion trap demonstrates optimal performance when the distance between the radio frequency electrodes is reduced to 0.686 mm, and it is suggested that the chamfer width of the endcap electrode extension be 0.6 mm. Based on this, the study further explored the machining accuracy of certain dimensions, concluding that the required high machining accuracy values for the radio frequency electrodes and the endcap electrodes are ±3 and ±7 μm, respectively, while the aperture machining accuracy requirements are ±3 and ±22 μm, respectively. In addition, the simulation results suggest that a conical surface on the radio frequency electrodes with a height of ∼0.08 mm aids in reducing anharmonicity, although a spherical end surface does not notably improve the electric field distribution. These findings provide a valuable reference for the optimized design and machining of ion traps.

AIP Advances•May 1, 2025•2 citations
A feedback control method for producing an equidistant ion string in a surface-electrode ion trap has been experimentally demonstrated. This method features three advantages: (i) The optimal voltage can be constrained within the specified reachable range. (ii) The height of trapped ions from the trap surface can be maintained at the same value when strings with different number of ions or with different ion spacings are to be trapped. (iii) This method is resistant to a stray electric field near the trap. By this method, the asymmetry of the ion string caused by a stray field is minimized. The robustness of trapping a variable number of ions at the same potential and the dependency of the axial frequency on the number of ions are also investigated experimentally. This work would be a practical method to create a linear ion string with a large number of ions and may find applications in large-scale quantum computing, quantum simulation, and phase transition studies utilizing homogeneous ion strings.
Phase transitions have been a research focus in many-body physics over past decades. Cold ions, under strong Coulomb repulsion, provide a repealing paradigm of exploring phase transitions in stable confinement by electromagnetic field. We demonstrate various conformations of up to sixteen laser-cooled (40)Ca(+) ion crystals in a home-built surface-electrode trap, where besides the usually mentioned structural phase transition from the linear to the zigzag, two additional phase transitions to more complicated two-dimensional configurations are identified. The experimental observation agrees well with the numerical simulation. Heating due to micromotion of the ions is analysed by comparison of the numerical simulation with the experimental observation. Our investigation implies very rich and complicated many-body behaviour in the trapped-ion systems and provides effective mechanism for further exploring quantum phase transitions and quantum information processing with ultracold trapped ions.
Ion traps serve as the venue for confining ions and exciting ionic transitions in ion optical clocks, where the geometric dimensions of the electrodes within the ion trap directly impact the performance metrics of the ion optical clocks. In this study, the finite element analysis method was employed to simulate the relationship between the electric field distribution and the dimensions of the electrodes in an endcap ion trap. The simulation data were subjected to curve fitting, with trap depth and potential anharmonicity utilized as the primary evaluation criteria for optimizing ion trap design. The results indicate that the ion trap demonstrates optimal performance when the distance between the radio frequency electrodes is reduced to 0.686 mm, and it is suggested that the chamfer width of the endcap electrode extension be 0.6 mm. Based on this, the study further explored the machining accuracy of certain dimensions, concluding that the required high machining accuracy values for the radio frequency electrodes and the endcap electrodes are ±3 and ±7 μm, respectively, while the aperture machining accuracy requirements are ±3 and ±22 μm, respectively. In addition, the simulation results suggest that a conical surface on the radio frequency electrodes with a height of ∼0.08 mm aids in reducing anharmonicity, although a spherical end surface does not notably improve the electric field distribution. These findings provide a valuable reference for the optimized design and machining of ion traps.