Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Spectral Hole-Burning and Related Spectroscopies: Science and Applications

Holeburning Optical Magnetic Resonance Imaging

Stephan Schiller, Robert L. Byer

Published Jan 1, 1991• 0 citations
Publisher

Abstract

Scanning probe microscopy and gradient imaging are two techniques for imaging at sub-wavelength spatial resolution. Gradient imaging in the form of magnetic resonance imaging (MRI) has so far been demonstrated only in the radio- and microwave frequency domains [1]. An extension of MRI to optical frequencies for imaging (semi-) transparent objects is of interest because an optical photon detection process is inherently more sensitive than magnetic induction detection, potentially leading to increased spatial resolution. Rare-earth ions incorporated into a crystalline host are promising as a prototype system for demonstration of high spatial resolution OMRI.

DOI
10.1364/pshb.1991.the5

Related papers

Subwavelength optical magnetic-resonance imaging

Stephan Schiller, Robert L. Byer

We present a theoretical study of optical magnetic-resonance imaging (OMRI), an extension of magnetic-resonance imaging to the optical frequency domain. OMRI images the spatial distribution of centers with field-dependent optical transitions by projection reconstruction from multiple tomographic scans. Spatial resolution is limited by magnetic-field gradient strengths and transition linewidths. These restrict the choice of systems accessible to OMRI, and rare-earth ions are identified as possible candidates. High-resolution laser spectroscopic techniques that overcome the effect of inhomogeneous broadening of electronic transitions are discussed. OMRI by transient hole-burning spectroscopy is presented as one approach for subwavelength spatial imaging, and its sensitivity is calculated. Submicrometer spatial resolution is possible by employing very-high-field gradients (>10 T/cm) and centers exhibiting megahertz linewidths.

Journal of the Optical Society of America A•May 1, 1992•5 citations

Optical Resonance Imaging: An Optical Analog to MRI with Subdiffraction-Limited Capabilities

Marco A. Allodi, Peter D. Dahlberg, Richard J. Mazuski +3 more

We propose here optical resonance imaging (ORI), a direct optical analog to magnetic resonance imaging (MRI). The proposed pulse sequence for ORI maps space to time and recovers an image from a heterodyne-detected third-order nonlinear photon echo measurement. As opposed to traditional photon echo measurements, the third pulse in the ORI pulse sequence has significant pulse-front tilt that acts as a temporal gradient. This gradient couples space to time by stimulating the emission of a photon echo signal from different lateral spatial locations of a sample at different times, providing a widefield ultrafast microscopy. We circumvent the diffraction limit of the optics by mapping the lateral spatial coordinate of the sample with the emission time of the signal, which can be measured to high precision using interferometric heterodyne detection. This technique is thus an optical analog of MRI, where magnetic-field gradients are used to localize the spin–echo emission to a point below the diffraction limit of the radio frequency wave used. We calculate the expected ORI signal using 15 fs pulses and 87° of pulse-front tilt, collected using f /2 optics, and find a two-point resolution of 275 nm using 800 nm light that satisfies the Rayleigh criterion. We also derive a general equation for resolution in optical resonance imaging that indicates that there is a possibility of superresolution imaging using this technique. The photon echo sequence also enables spectroscopic determination of the input and output energy. The technique thus correlates the input energy with the final position and energy of the exciton.

ACS Photonics•Nov 21, 2016•4 citations

Restoring Narrow Linewidth to a Gradient-Broadened Magnetic Resonance by Inhomogeneous Dressing

G. Bevilacqua, V. Biancalana, Yordanka V. Dancheva +1 more

The low-frequency signal from ultralow-field magnetic resonance imaging (ULF-MRI) setups leads to the use of high-sensitivity noninductive detectors. The simplicity and robustness of optical atomic magnetometers (OAMs) make them excellent candidates to this end, but they suffer from magnetic field inhomogeneities. Appropriate magnetic ``dressing'' of precessing atomic spins can overcome this limitation: Applying a dressing field with opportune inhomogeneity compensates the atomic line broadening induced by the MRI gradient, restoring OAM sensitivity and enabling $i\phantom{\rule{0}{0ex}}n$ $s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}t\phantom{\rule{0}{0ex}}u$ detection of ULF-MRI signals by optical magnetometry.

arXiv:1807.01274•Physical Review Applied•Feb 20, 2019•15 citations

Optical magnetic resonance imaging with an ultra-narrow optical transition

Shinya Kato, Kosuke Shibata, Ryuta Yamamoto +2 more

Applied Physics B•Feb 7, 2012•15 citations

Tomographic imaging of cold atoms and sensing of external fields in three dimensions

Michal P. Parniak, Mateusz Mazelanik

Optical tomography can reveal the intrinsic structure of complex objects with high accuracy. Cold atoms are an excellent model physical system for designing new protocols. By combining the gradient echo memory protocol with spatial homodyne detection, our experiment achieved micron-level resolution and excellent shot-noise limited sensitivity for interrogating atomic coherence. We also demonstrated three-dimensional imaging of an external magnetic field, and plan to extend the scheme to ultra-sensitive three-dimensional imaging of microwave fields using Rydberg atoms. Our work pushes the boundaries of quantum sensing for weak fields and unexplored three-dimensional tomographic imaging. The method may also be applied to hot atoms or solid-state probes, such as color centers, or ions, embedded in an interrogated medium.

Quantum Communications and Quantum Imaging•Oct 3, 2023•0 citations

Optical Lithography and Atom Localization beyond the Diffraction Limit via Rabi Gradient

Zeyang Liao

The resolution of traditional optical microscope and optical lithography is limited by about half wavelength of the light source, which is well known as the diffraction limit or Abbe limit. The resolution limit is due to the missing of high spatial frequency components in the far-field. One way to achieve high resolution is to move the detector into the near-field region where the evanescent wave can be collected. However, these methods are surface-bound and usually very slow which have limited applications. It has long been an interesting and important question about how to overcome the diffraction limit in the far-field. For optical lithography, a number of methods have been proposed to overcome the diffraction limit such as multi-photon scanning, quantum entanglement, quantum inspired process (e.g., dopperlon), and quantum dark state. However, these methods either require multi-photon absorber, quantum entanglement, or multi-energy levels, which restrict them from extending to higher resolution in practice. In this thesis, we showed that sub-diffraction-limited resolution can be generated by the coherent Rabi gradient. This method does not require multi-photon absorber or quantum entanglement but just quantum coherence of the medium. Extension from lower resolution to higher resolution is very straightforward where we just need to increase the pulse intensity or pulse duration. We also proposed two atom lithography experiments based on the Rabi gradient. The first one uses Rubidium Rydberg atom and microwave where we showed that sub-micrometer line spacing is possible. The second one uses Chromium atom and optical field where we showed that sub-10nm line spacing is possible while the wavelength of the light is about 400nm. For optical imaging, a number of methods have also been proposed to achieve super-resolution such as multi-photon microscope, stimulated-emission-depletion, structured illumination microscopy, centroid-based techniques and metamaterial-based lens. Here, we will show a new method to achieve resolution beyond the diffraction limit which we called it resonance fluorescence microscopy. Resonance fluorescence has been proposed to localize a single atom with resolution beyond the diffraction limit. The separation between two atoms can also be extracted from the resonance fluorescence spectrum. To develop it as microscopy, we need to evaluate the resonance fluorescence spectrum of multiple-atom system. We analytically solved the general feature of the spectrum when the Rabi frequency is much larger than the dipole-dipole interaction and showed how to extract the spatial information of the atoms with resolution far beyond the diffraction limit. This method is entirely based on far-field techniques and it does not require point-by-point scanning.

•Jul 28, 2014•0 citations
Scanning probe microscopy and gradient imaging are two techniques for imaging at sub-wavelength spatial resolution. Gradient imaging in the form of magnetic resonance imaging (MRI) has so far been demonstrated only in the radio- and microwave frequency domains [1]. An extension of MRI to optical frequencies for imaging (semi-) transparent objects is of interest because an optical photon detection process is inherently more sensitive than magnetic induction detection, potentially leading to increased spatial resolution. Rare-earth ions incorporated into a crystalline host are promising as a prototype system for demonstration of high spatial resolution OMRI.
We present a theoretical study of optical magnetic-resonance imaging (OMRI), an extension of magnetic-resonance imaging to the optical frequency domain. OMRI images the spatial distribution of centers with field-dependent optical transitions by projection reconstruction from multiple tomographic scans. Spatial resolution is limited by magnetic-field gradient strengths and transition linewidths. These restrict the choice of systems accessible to OMRI, and rare-earth ions are identified as possible candidates. High-resolution laser spectroscopic techniques that overcome the effect of inhomogeneous broadening of electronic transitions are discussed. OMRI by transient hole-burning spectroscopy is presented as one approach for subwavelength spatial imaging, and its sensitivity is calculated. Submicrometer spatial resolution is possible by employing very-high-field gradients (>10 T/cm) and centers exhibiting megahertz linewidths.
We propose here optical resonance imaging (ORI), a direct optical analog to magnetic resonance imaging (MRI). The proposed pulse sequence for ORI maps space to time and recovers an image from a heterodyne-detected third-order nonlinear photon echo measurement. As opposed to traditional photon echo measurements, the third pulse in the ORI pulse sequence has significant pulse-front tilt that acts as a temporal gradient. This gradient couples space to time by stimulating the emission of a photon echo signal from different lateral spatial locations of a sample at different times, providing a widefield ultrafast microscopy. We circumvent the diffraction limit of the optics by mapping the lateral spatial coordinate of the sample with the emission time of the signal, which can be measured to high precision using interferometric heterodyne detection. This technique is thus an optical analog of MRI, where magnetic-field gradients are used to localize the spin–echo emission to a point below the diffraction limit of the radio frequency wave used. We calculate the expected ORI signal using 15 fs pulses and 87° of pulse-front tilt, collected using f /2 optics, and find a two-point resolution of 275 nm using 800 nm light that satisfies the Rayleigh criterion. We also derive a general equation for resolution in optical resonance imaging that indicates that there is a possibility of superresolution imaging using this technique. The photon echo sequence also enables spectroscopic determination of the input and output energy. The technique thus correlates the input energy with the final position and energy of the exciton.
The low-frequency signal from ultralow-field magnetic resonance imaging (ULF-MRI) setups leads to the use of high-sensitivity noninductive detectors. The simplicity and robustness of optical atomic magnetometers (OAMs) make them excellent candidates to this end, but they suffer from magnetic field inhomogeneities. Appropriate magnetic ``dressing'' of precessing atomic spins can overcome this limitation: Applying a dressing field with opportune inhomogeneity compensates the atomic line broadening induced by the MRI gradient, restoring OAM sensitivity and enabling $i\phantom{\rule{0}{0ex}}n$ $s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}t\phantom{\rule{0}{0ex}}u$ detection of ULF-MRI signals by optical magnetometry.
Optical tomography can reveal the intrinsic structure of complex objects with high accuracy. Cold atoms are an excellent model physical system for designing new protocols. By combining the gradient echo memory protocol with spatial homodyne detection, our experiment achieved micron-level resolution and excellent shot-noise limited sensitivity for interrogating atomic coherence. We also demonstrated three-dimensional imaging of an external magnetic field, and plan to extend the scheme to ultra-sensitive three-dimensional imaging of microwave fields using Rydberg atoms. Our work pushes the boundaries of quantum sensing for weak fields and unexplored three-dimensional tomographic imaging. The method may also be applied to hot atoms or solid-state probes, such as color centers, or ions, embedded in an interrogated medium.
The resolution of traditional optical microscope and optical lithography is limited by about half wavelength of the light source, which is well known as the diffraction limit or Abbe limit. The resolution limit is due to the missing of high spatial frequency components in the far-field. One way to achieve high resolution is to move the detector into the near-field region where the evanescent wave can be collected. However, these methods are surface-bound and usually very slow which have limited applications. It has long been an interesting and important question about how to overcome the diffraction limit in the far-field. For optical lithography, a number of methods have been proposed to overcome the diffraction limit such as multi-photon scanning, quantum entanglement, quantum inspired process (e.g., dopperlon), and quantum dark state. However, these methods either require multi-photon absorber, quantum entanglement, or multi-energy levels, which restrict them from extending to higher resolution in practice. In this thesis, we showed that sub-diffraction-limited resolution can be generated by the coherent Rabi gradient. This method does not require multi-photon absorber or quantum entanglement but just quantum coherence of the medium. Extension from lower resolution to higher resolution is very straightforward where we just need to increase the pulse intensity or pulse duration. We also proposed two atom lithography experiments based on the Rabi gradient. The first one uses Rubidium Rydberg atom and microwave where we showed that sub-micrometer line spacing is possible. The second one uses Chromium atom and optical field where we showed that sub-10nm line spacing is possible while the wavelength of the light is about 400nm. For optical imaging, a number of methods have also been proposed to achieve super-resolution such as multi-photon microscope, stimulated-emission-depletion, structured illumination microscopy, centroid-based techniques and metamaterial-based lens. Here, we will show a new method to achieve resolution beyond the diffraction limit which we called it resonance fluorescence microscopy. Resonance fluorescence has been proposed to localize a single atom with resolution beyond the diffraction limit. The separation between two atoms can also be extracted from the resonance fluorescence spectrum. To develop it as microscopy, we need to evaluate the resonance fluorescence spectrum of multiple-atom system. We analytically solved the general feature of the spectrum when the Rabi frequency is much larger than the dipole-dipole interaction and showed how to extract the spatial information of the atoms with resolution far beyond the diffraction limit. This method is entirely based on far-field techniques and it does not require point-by-point scanning.