Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics & Laser Technology

Influence of pumping power density on output intensities and stabilities of competitive multi-line frequency up-conversions in cesium vapor

Baodong Gai, Shu Hu, Xueyang Li, Hong Yuan, Xianglong Cai, Jinbo Liu, Jingwei Guo, Yuqi Jin, Fengting Sang

Published Apr 29, 2017• 4 citations
Publisher
DOI
10.1016/j.optlastec.2017.03.044

Related papers

Modulation of a double-line frequency up-conversion process in cesium vapor

Baodong Gai, Rui Cao, Xusheng Xia +7 more

Applied Physics B•May 28, 2016•19 citations

基于双四波混频过程在铯原子气室中产生相干蓝光

刘珂鑫 Liu Kexin, 吕昕勃 Lü Xinbo, 赵成浩 Zhao Chenghao +2 more

Object This study is based on a two-diamond energy level system of cesium atoms described as 6S1/2→6P3/2→6D3/2→7P3/2→6S1/2 and 6S1/2→6P3/2→6D3/2→7P1/2→6S1/2. When two high-power pump laser beams with wavelengths of 852 nm and 921 nm simultaneously act on the 6S1/2→6P3/2 and 6P3/2→6D3/2 ultrafine transition lines, a double four-wave mixing process occurs in a heated cesium-atom vapor chamber, and two coherent blue light beams with wavelengths of 455 nm (7P3/2→6S1/2) and 459 nm (7P1/2→6S1/2) are generated through frequency conversion. The two beams are experimentally studied in the absence of gravity-pump light. The dependence of pump laser detuning, power, and cesium-atom gas chamber temperature on the intensity of the two generated blue light beams is also studied. Methods In this experiment, the 921 nm pump light was generated by a continuously tunable titanium-doped sapphire laser (with a maximum output power of 1 W), while the 852 nm pump light was provided by an external cavity diode laser. After amplification, the maximum output power was 1.2 W. Two sets of half wave plates (HWPs) and polarizing beam splitters (PBS) were used to process these two laser beams. Subsequently, the 921 nm and 852 nm pump lights were reflected by mirror M3 and coincided at the dichroic mirror (DM), propagating in the same direction. After passing through a quarter-wave plate (QWP), both laser beams changed from linearly to circularly polarized light with the same rotation direction, ensuring the highest efficiency in blue light generation. Telescopic systems composed of two lenses with a focal length of 100 mm were placed in front of and behind the cell, with the cell placed at the confocal center to increase the power density acting on the medium. Finally, the angles of the two pump lights were adjusted to satisfy the angle phase-matching condition, and the temperature control system of the Cs atomic vapor chamber was adjusted to satisfy the phase-matching condition. Results and Discussions First, we analyze the influence of the pump laser power and temperature of the cesium vapor cell on the power of the two generated blue lights. Figures 2(a) and (b) show the relationship between the power of the 852 nm and 921 nm pump lasers and the power of the generated blue light, respectively, while Fig. 4 shows the curves of the power of the two blue lights changing with the temperature of the cesium vapor cell. We conclude that when the power of the pump lasers is high and there is no 895 nm repumping light, the power of the generated blue light depends on temperature, which first increases and then decreases. It also depends on the power of the pump lasers, which first increases and then reaches a specific threshold.The detuning of the pump laser is varied to observe its effect on the blue light. Figure 3 shows the dependence of the intensity of the coherent blue lights at 455 nm and 459 nm on the frequency detuning of the 852 nm and 921 nm pump lasers. We conclude that the frequency detuning range of the pump laser corresponding to 455 nm is wider than that of the pump laser corresponding to 459 nm, and the intensity is higher. The small frequency detuning range of the pump laser corresponding to 459 nm indicates that under this condition, it is easier to generate 455 nm blue light than 459 nm blue light. Conclusions In this experiment, based on the two energy level systems of cesium atoms, 852 nm and 921 nm pump lasers were used to generate two 455 nm and 459 nm blue light beams through a four-wave mixing process under phase-matching conditions in a cesium vapor cell. The intensity of blue light was measured under angle and temperature phase-matching conditions, with the maximum power of 455 nm and 459 nm blue laser light reaching 3.03 mW and 4.5 mW, respectively, when the temperature of the cesium vapor cell was 110 ℃, the power of the 921 nm pump light was 150 mW, and the power of the 852 nm pump light was 460 mW. The conversion efficiency was 10.91%/W. We also compared the experimental results with the addition of a single 895 nm repumping light, which showed the same trend of light intensity change as the pump light and provided a more straightforward experimental operation to verify the generation of blue light by the four-wave mixing process in cesium atoms.

Chinese Journal of Lasers•Jan 1, 2025•1 citation

Diode-laser pumped Raman-shifted oscillation in cesium vapor

Matt Poelker, Prem Kumar, Philip Hemmer

We report observing Raman-shifted oscillation within a ring cavity containing cesium vapor and pumped with the output of a single-frequency diode laser tuned near the D2 line. The oscillation is shifted from the diode-laser pump frequency by ≃9 GHz, the hyperfine splitting of the 6S1/2 ground state of cesium. Many different transverse modes of oscillation are observed for slight variations in the cavity alignment. In addition, the oscillation is observed to turn on and off at 60 Hz as a result of the pump-frequency fluctuations associated with the line noise on the diode-laser drive current. The pump-frequency fluctuations (≃10 MHz) are small compared with the free spectral range (175 MHz) of the ring cavity. These characteristics indicate that the Raman oscillation in cesium vapor is narrow-band, similar to the behavior observed in sodium vapor.1–3 As little as 30 mW of pump power is required for oscillation when highly reflective cavity optics are used. We have obtained 0.5 mW of Raman-shifted output with an appropriate output coupler at 65 mW of pump power.

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations

Numerical simulation of dense cesium vapor emission and absorption spectra

Berislav Horvatić, Robert Beuc, Mladen Movre

The European Physical Journal D•Apr 1, 2015•8 citations

Light Amplification in Diode-pumped Cesium Vapor Cell

Jongmin Hwang, Taek Jeong, Han Seb Moon

한국광학회지•Dec 1, 2018•0 citations

Light narrowing of magnetic resonance lines in dense, optically pumped alkali-metal vapor

Natarajan D. Bhaskar, James C. Camparo, W. Happer +1 more

A new and unusual phenomenon which we call light narrowing is reported and discussed in this paper. We discovered this effect in dense, spin-polarized cesium vapor optically pumped with a cw blue dye laser beam tuned to the second resonance ${D}_{1}$ line (4593 \AA{}). We observe a significant narrowing of the radio-frequency power-broadened magnetic resonance lines (linewidths narrow by as much as a factor of 2.5) when the intensity of the circularly polarized incident dye laser beam is increased by either focusing the beam or by the removal of attenuating filters from the focused beam. The magnetic resonance linewidths in spin-polarized cesium vapor were measured over a wide range of cesium number densities (5\ifmmode\times\else\texttimes\fi{}${10}^{12}$ ${\mathrm{cm}}^{\ensuremath{-}3}$ \ensuremath{\le}[Cs]\ensuremath{\le}1\ifmmode\times\else\texttimes\fi{}${10}^{16}$ ${\mathrm{cm}}^{\ensuremath{-}3}$). This corresponds to cesium spinexchange rates of 4.5\ifmmode\times\else\texttimes\fi{}${10}^{3}$ to 9\ifmmode\times\else\texttimes\fi{}${10}^{6}$ ${\mathrm{sec}}^{\ensuremath{-}1}$. For low cesium number densities (5\ifmmode\times\else\texttimes\fi{}${10}^{12}$ [Cs]3\ifmmode\times\else\texttimes\fi{}${10}^{14}$ ${\mathrm{cm}}^{\ensuremath{-}3}$) the light-narrowing effect is large (a factor of 2.5) and independent of [Cs]. In the region of 3\ifmmode\times\else\texttimes\fi{}${10}^{14}$ to 1\ifmmode\times\else\texttimes\fi{}${10}^{15}$ ${\mathrm{cm}}^{\ensuremath{-}3}$ in number densities, the light-narrowing effect decreases with increasing [Cs]. At high cesium number densities ([Cs]> 1\ifmmode\times\else\texttimes\fi{}${10}^{15}$ ${\mathrm{cm}}^{\ensuremath{-}3}$) this light-narrowing effect almost completely disappears. In the limit of low-radio-frequency power the magnetic resonance linewidths for focused and unfocused dye laser beam are nearly the same. Experimental observations on this new effect are presented in detail. In the latter part of this paper a self-contained theoretical treatment of the light-narrowing effect is developed. Using Bloch equations in the presence of optical pumping, spin relaxation (diffusion, electron randomization), rapid spin exchange, and radio-frequency magnetic field, expressions for magnetic resonance line shapes are derived. In general, we find good agreement between our experimental results and the theory.

Physical Review A•Jun 1, 1981•58 citations
Object This study is based on a two-diamond energy level system of cesium atoms described as 6S1/2→6P3/2→6D3/2→7P3/2→6S1/2 and 6S1/2→6P3/2→6D3/2→7P1/2→6S1/2. When two high-power pump laser beams with wavelengths of 852 nm and 921 nm simultaneously act on the 6S1/2→6P3/2 and 6P3/2→6D3/2 ultrafine transition lines, a double four-wave mixing process occurs in a heated cesium-atom vapor chamber, and two coherent blue light beams with wavelengths of 455 nm (7P3/2→6S1/2) and 459 nm (7P1/2→6S1/2) are generated through frequency conversion. The two beams are experimentally studied in the absence of gravity-pump light. The dependence of pump laser detuning, power, and cesium-atom gas chamber temperature on the intensity of the two generated blue light beams is also studied. Methods In this experiment, the 921 nm pump light was generated by a continuously tunable titanium-doped sapphire laser (with a maximum output power of 1 W), while the 852 nm pump light was provided by an external cavity diode laser. After amplification, the maximum output power was 1.2 W. Two sets of half wave plates (HWPs) and polarizing beam splitters (PBS) were used to process these two laser beams. Subsequently, the 921 nm and 852 nm pump lights were reflected by mirror M3 and coincided at the dichroic mirror (DM), propagating in the same direction. After passing through a quarter-wave plate (QWP), both laser beams changed from linearly to circularly polarized light with the same rotation direction, ensuring the highest efficiency in blue light generation. Telescopic systems composed of two lenses with a focal length of 100 mm were placed in front of and behind the cell, with the cell placed at the confocal center to increase the power density acting on the medium. Finally, the angles of the two pump lights were adjusted to satisfy the angle phase-matching condition, and the temperature control system of the Cs atomic vapor chamber was adjusted to satisfy the phase-matching condition. Results and Discussions First, we analyze the influence of the pump laser power and temperature of the cesium vapor cell on the power of the two generated blue lights. Figures 2(a) and (b) show the relationship between the power of the 852 nm and 921 nm pump lasers and the power of the generated blue light, respectively, while Fig. 4 shows the curves of the power of the two blue lights changing with the temperature of the cesium vapor cell. We conclude that when the power of the pump lasers is high and there is no 895 nm repumping light, the power of the generated blue light depends on temperature, which first increases and then decreases. It also depends on the power of the pump lasers, which first increases and then reaches a specific threshold.The detuning of the pump laser is varied to observe its effect on the blue light. Figure 3 shows the dependence of the intensity of the coherent blue lights at 455 nm and 459 nm on the frequency detuning of the 852 nm and 921 nm pump lasers. We conclude that the frequency detuning range of the pump laser corresponding to 455 nm is wider than that of the pump laser corresponding to 459 nm, and the intensity is higher. The small frequency detuning range of the pump laser corresponding to 459 nm indicates that under this condition, it is easier to generate 455 nm blue light than 459 nm blue light. Conclusions In this experiment, based on the two energy level systems of cesium atoms, 852 nm and 921 nm pump lasers were used to generate two 455 nm and 459 nm blue light beams through a four-wave mixing process under phase-matching conditions in a cesium vapor cell. The intensity of blue light was measured under angle and temperature phase-matching conditions, with the maximum power of 455 nm and 459 nm blue laser light reaching 3.03 mW and 4.5 mW, respectively, when the temperature of the cesium vapor cell was 110 ℃, the power of the 921 nm pump light was 150 mW, and the power of the 852 nm pump light was 460 mW. The conversion efficiency was 10.91%/W. We also compared the experimental results with the addition of a single 895 nm repumping light, which showed the same trend of light intensity change as the pump light and provided a more straightforward experimental operation to verify the generation of blue light by the four-wave mixing process in cesium atoms.
We report observing Raman-shifted oscillation within a ring cavity containing cesium vapor and pumped with the output of a single-frequency diode laser tuned near the D2 line. The oscillation is shifted from the diode-laser pump frequency by ≃9 GHz, the hyperfine splitting of the 6S1/2 ground state of cesium. Many different transverse modes of oscillation are observed for slight variations in the cavity alignment. In addition, the oscillation is observed to turn on and off at 60 Hz as a result of the pump-frequency fluctuations associated with the line noise on the diode-laser drive current. The pump-frequency fluctuations (≃10 MHz) are small compared with the free spectral range (175 MHz) of the ring cavity. These characteristics indicate that the Raman oscillation in cesium vapor is narrow-band, similar to the behavior observed in sodium vapor.1–3 As little as 30 mW of pump power is required for oscillation when highly reflective cavity optics are used. We have obtained 0.5 mW of Raman-shifted output with an appropriate output coupler at 65 mW of pump power.
A new and unusual phenomenon which we call light narrowing is reported and discussed in this paper. We discovered this effect in dense, spin-polarized cesium vapor optically pumped with a cw blue dye laser beam tuned to the second resonance D1{D}_{1}D1​ line (4593 \AA{}). We observe a significant narrowing of the radio-frequency power-broadened magnetic resonance lines (linewidths narrow by as much as a factor of 2.5) when the intensity of the circularly polarized incident dye laser beam is increased by either focusing the beam or by the removal of attenuating filters from the focused beam. The magnetic resonance linewidths in spin-polarized cesium vapor were measured over a wide range of cesium number densities (5\ifmmode\times\else\texttimes\fi{}1012{10}^{12}1012 ${\mathrm{cm}}^{\ensuremath{-}3}$ \ensuremath{\le}[Cs]\ensuremath{\le}1\ifmmode\times\else\texttimes\fi{}1016{10}^{16}1016 ${\mathrm{cm}}^{\ensuremath{-}3}$). This corresponds to cesium spinexchange rates of 4.5\ifmmode\times\else\texttimes\fi{}103{10}^{3}103 to 9\ifmmode\times\else\texttimes\fi{}106{10}^{6}106 ${\mathrm{sec}}^{\ensuremath{-}1}$. For low cesium number densities (5\ifmmode\times\else\texttimes\fi{}1012{10}^{12}1012 [Cs]3\ifmmode\times\else\texttimes\fi{}1014{10}^{14}1014 ${\mathrm{cm}}^{\ensuremath{-}3}$) the light-narrowing effect is large (a factor of 2.5) and independent of [Cs]. In the region of 3\ifmmode\times\else\texttimes\fi{}1014{10}^{14}1014 to 1\ifmmode\times\else\texttimes\fi{}1015{10}^{15}1015 ${\mathrm{cm}}^{\ensuremath{-}3}$ in number densities, the light-narrowing effect decreases with increasing [Cs]. At high cesium number densities ([Cs]> 1\ifmmode\times\else\texttimes\fi{}1015{10}^{15}1015 ${\mathrm{cm}}^{\ensuremath{-}3}$) this light-narrowing effect almost completely disappears. In the limit of low-radio-frequency power the magnetic resonance linewidths for focused and unfocused dye laser beam are nearly the same. Experimental observations on this new effect are presented in detail. In the latter part of this paper a self-contained theoretical treatment of the light-narrowing effect is developed. Using Bloch equations in the presence of optical pumping, spin relaxation (diffusion, electron randomization), rapid spin exchange, and radio-frequency magnetic field, expressions for magnetic resonance line shapes are derived. In general, we find good agreement between our experimental results and the theory.