Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

The 1064nm quadrature squeezed state preparation of applied to quantum detection

Zhiqiang Wu, Xuling Lin, Song Yang, Xuan Zhang, Yaohui Zheng

Published Mar 8, 2017• 0 citations
Publisher

Abstract

Squeezed state light field can surpass the shot noise limit and improve the signal-to-noise ratio of the sensor measurement. In this paper, based on optical parametric amplification (OPA), we present employed a semi-monolithic cavity and miniaturization design of optical parametric amplifier (OPA) to improve system stability. The infrared spectrum 1064nm quadrature squeezed state field of noise squeezing degree 6.75dB is obtained by pumped the PPKTP crystal via 532nm laser. This work provides a practical light source for quantum sensing detection.

DOI
10.1117/12.2268733

Related papers

Manipulations and quantum tomography of bright squeezed states

Qinghui Li, Wenxiu Yao, Li Fan +3 more

Generation and manipulation of continuous variable quantum states are the building blocks of quantum communication, quantum key distribution and quantum networks. According to the second-order nonlinear process of the periodically-poled potassium titanyl phosphate (PPKTP) crystal, we design a semi-monolithic optical parametric amplifier (OPA) cavity to generate the bright squeezed light at a wavelength of 1064 nm. With the injection of a seed beam, the squeezed state generated by the OPA has a coherent amplitude, so called bright squeezed state. The squeezing level is directly observed to be –11.6 dB when the pump power is 310 mW at an analysis frequency of 3 MHz. However, with the increase of the pump power, the purity of the squeezed state gets lower and lower due to the increased influence of the anti-squeezing quadrature component on the squeezed quadrature component in the detection process. To obtain a higher purity of the squeezed state for achieving linear optical manipulation and quantum tomography, we choose the pump power of 50 mW, the squeezing level decreases to –6 dB, and the purity of the squeezed state is 98.5% in this case. An electro-optic modulator is adopted to realize the liner manipulation of the squeezed light in the phase space. During the measurement of the bright squeezed state, all the data are taken on condition that the length of the OPA cavity and relative phase between the seed beam and the pump beam are locked by a locking loop. The direct current (DC) signal of the balanced homodyne detection (BHD) is used to accurately determine the phase corresponding to the time domain signal of the squeezed state, while the alternate current (AC) signal of the BHD is mixed with the signal generated by the function generator, after passing through a low-pass filter and a high-pass filter, the signal is then amplified by using a low-noise amplifier. A high-performance oscilloscope is finally used to simultaneously collect the signals, thus obtaining the quantum noise signal of the bright squeezed light after linear manipulation. Together with the maximum likelihood estimation algorithm, the quantum tomography, the density matrix and the Wigner function of the bright squeezed light are obtained, that is, all the information such as the photon number distribution of the quantum state is determined. Multiple iterations are taken in the maximum likelihood estimation algorithm process to eliminate the influence of the low quantum efficiency on the detection system, so that the density matrix is fitted well with the theoretical results.

Acta Physica Sinica•Jan 1, 2021•5 citations

A Bright Squeezed Light Source for Quantum Sensing

Wenhai Yang, Wenting Diao, Chunxiao Cai +8 more

The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.

Chemosensors•Dec 25, 2022•13 citations

Theoretical and experimental study on methods for increasing squeezed level in the generation of squeezed light

Fei Feng, Wenyan Qu, Jiazheng Song +1 more

We demonstrate the methods for increasing the observed squeezing level in the generation of squeezed states of light at 1064 nm with periodically poled KTiOPO4 (PPKTP) crystal. We analyze the technical limits to the reduction of noise in the squeezed quadrature theoretically, including the intra-cavity loss of the optical parametric amplifier (OPA) cavity, the normalized amplitude, the detection frequency, and the mode matching on the balanced homodyning stage. To observe a high degree of squeezing, we improve the quality of mode matching into the OPA cavity and the mode cleaning (MC) cavity experimentally. By optimizing mode matching of the light into cavities, the finesse of the cavities would be higher in practice and the desirable spatial mode can be realized. As the intensity noise of the laser light reach the shot noise limit above the frequency of 1 MHz, which is sufficient for our experiment, so the MC cavity is incorporated to filter higher-order transverse modes of the local oscillator (LO) beam for the balanced homodyne detection. The experimental and theoretical results show that it is essential to optimize the mode matching efficiency to generate and detect high degree of squeezing otherwise an inefficiency mode matching will throw away the squeezing and transform the squeezed field into a vacuum field.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 21, 2013•0 citations

Preparation of continuously tunable orthogonal squeezed light filed corresponding to cesium D1 line

Yan Zhang, Juan Yu, Pengfei Yang +1 more

The non-classical light resonance on the cesium D1 (894.6 nm) line has important applications in solid-state quantum information networks due to its unique advantages. The cesium D1 line has a simplified hyperfine structure and can be used to realize a light-atom interface. In our previous work, we demonstrated 2.8-dB quadrature squeezed vacuum light at cesium D1 line in an optical parametric oscillator(OPO) with a periodically poled KTP(PPKTP) crystal. However, the squeezing level is relatively low, and the tunability that has practical significance for squeezed light has not been further investigated. Theoretically, the increase of the transmittance of output mirror and the decrease of the intra-cavity loss of the OPO can improve the squeezing level. Here, we use super-polished and optimal coating cavity mirrors to improve the nonlinear process in OPO. We prepare 447.3 nm blue light from 894.6 nm fundamental light by a second harmonic generation cavity (SHG). The SHG is a two-mirror standing-wave cavity with a PPKTP crystal as the nonlinear medium. The power of generated blue laser is 32 mW when the incident infrared power is 120 mW. Using the blue light to pump an OPO, we achieve quadrature squeezed vacuum light at cesium D1 line. The OPO is a two-mirror standing-wave cavity with a PPKTP crystal. The threshold of OPO is reduced to 28 mW. The squeezing level of generated quadrature squeezed vacuum light is increased to 3.3 dB when the pump power is 15 mW. Taking into account the overall detection efficiency, the actual squeezing reaches 5.5 dB. We inject a weak signal beam into the OPO cavity to act as an optical parametric amplifier (OPA), and test the tunability of squeezzed light. The blue light and the squeezed light are tuned by using a low-frequency triangular wave signal to scan the Ti: sapphire laser. Gradually increasing the amplitude of the scanning triangle wave signal, the generated bright squeezed light can be continuously tuned over a range around 80 MHz without losing the stability of the whole system. The generated squeezed light offers the possibility for the efficient coupling between the non-classical source and solid medium in the process of quantum interface.

Acta Physica Sinica•Jan 1, 2022•3 citations

Experimental study on the imaging of the squeezed state light at 1064 nm

L. Chen, Shulei Bi, Bao zhu Lu

Stable, low noise, infrared squeezed state tight at 1064 nm is generated by utilizing optical parametric down-conversion (OPDC) technique based on periodically poled KTiOPO 4 in a optical parametric amplifier (OPA) resonator. A non-classical noise reduction of 2.58 dB below the shot noise is observed through balanced homodyne detection. The squeezed state light is used to set up an imaging system for high-resolution imaging, and it is found that the resolution of image based on the amplitude-squeezed light is 1.26 times larger than that of infrared coherent light under the same intensity. The experimental results indicate that squeezed light is an important non-classical light, which can overcome the coherent laser shot-noise, the classical diffraction limit and limit of quantum noise.

Laser Physics•May 25, 2011•11 citations

Quantum Nondemolition Measurements Improved by a Squeezed Meter Input

Robert Bruckmeier, Klaus Schneider, Stephan Schiller +1 more

Continuous quantum nondemolition (QND) measurements of the amplitude quadrature of a 1064 nm wave are performed with a monolithic dual-port degenerate optical parametric amplifier (OPA). The quality of the measurement is limited in part by the quantum fluctuations carried by the vacuum meter input wave. Improved QND measurements are realized by injecting 3.4 dB amplitude-squeezed light into the meter input port of the OPA. This achieves increased squeezing and correlation of the output signal and meter waves, and both improved operation as a quantum optical tap and as a quantum state preparator. The all-solid-state system was operated for 5 h with high stability.

Physical Review Letters•Feb 17, 1997•35 citations
Squeezed state light field can surpass the shot noise limit and improve the signal-to-noise ratio of the sensor measurement. In this paper, based on optical parametric amplification (OPA), we present employed a semi-monolithic cavity and miniaturization design of optical parametric amplifier (OPA) to improve system stability. The infrared spectrum 1064nm quadrature squeezed state field of noise squeezing degree 6.75dB is obtained by pumped the PPKTP crystal via 532nm laser. This work provides a practical light source for quantum sensing detection.
Generation and manipulation of continuous variable quantum states are the building blocks of quantum communication, quantum key distribution and quantum networks. According to the second-order nonlinear process of the periodically-poled potassium titanyl phosphate (PPKTP) crystal, we design a semi-monolithic optical parametric amplifier (OPA) cavity to generate the bright squeezed light at a wavelength of 1064 nm. With the injection of a seed beam, the squeezed state generated by the OPA has a coherent amplitude, so called bright squeezed state. The squeezing level is directly observed to be –11.6 dB when the pump power is 310 mW at an analysis frequency of 3 MHz. However, with the increase of the pump power, the purity of the squeezed state gets lower and lower due to the increased influence of the anti-squeezing quadrature component on the squeezed quadrature component in the detection process. To obtain a higher purity of the squeezed state for achieving linear optical manipulation and quantum tomography, we choose the pump power of 50 mW, the squeezing level decreases to –6 dB, and the purity of the squeezed state is 98.5% in this case. An electro-optic modulator is adopted to realize the liner manipulation of the squeezed light in the phase space. During the measurement of the bright squeezed state, all the data are taken on condition that the length of the OPA cavity and relative phase between the seed beam and the pump beam are locked by a locking loop. The direct current (DC) signal of the balanced homodyne detection (BHD) is used to accurately determine the phase corresponding to the time domain signal of the squeezed state, while the alternate current (AC) signal of the BHD is mixed with the signal generated by the function generator, after passing through a low-pass filter and a high-pass filter, the signal is then amplified by using a low-noise amplifier. A high-performance oscilloscope is finally used to simultaneously collect the signals, thus obtaining the quantum noise signal of the bright squeezed light after linear manipulation. Together with the maximum likelihood estimation algorithm, the quantum tomography, the density matrix and the Wigner function of the bright squeezed light are obtained, that is, all the information such as the photon number distribution of the quantum state is determined. Multiple iterations are taken in the maximum likelihood estimation algorithm process to eliminate the influence of the low quantum efficiency on the detection system, so that the density matrix is fitted well with the theoretical results.
The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.
We demonstrate the methods for increasing the observed squeezing level in the generation of squeezed states of light at 1064 nm with periodically poled KTiOPO4 (PPKTP) crystal. We analyze the technical limits to the reduction of noise in the squeezed quadrature theoretically, including the intra-cavity loss of the optical parametric amplifier (OPA) cavity, the normalized amplitude, the detection frequency, and the mode matching on the balanced homodyning stage. To observe a high degree of squeezing, we improve the quality of mode matching into the OPA cavity and the mode cleaning (MC) cavity experimentally. By optimizing mode matching of the light into cavities, the finesse of the cavities would be higher in practice and the desirable spatial mode can be realized. As the intensity noise of the laser light reach the shot noise limit above the frequency of 1 MHz, which is sufficient for our experiment, so the MC cavity is incorporated to filter higher-order transverse modes of the local oscillator (LO) beam for the balanced homodyne detection. The experimental and theoretical results show that it is essential to optimize the mode matching efficiency to generate and detect high degree of squeezing otherwise an inefficiency mode matching will throw away the squeezing and transform the squeezed field into a vacuum field.
The non-classical light resonance on the cesium D1 (894.6 nm) line has important applications in solid-state quantum information networks due to its unique advantages. The cesium D1 line has a simplified hyperfine structure and can be used to realize a light-atom interface. In our previous work, we demonstrated 2.8-dB quadrature squeezed vacuum light at cesium D1 line in an optical parametric oscillator(OPO) with a periodically poled KTP(PPKTP) crystal. However, the squeezing level is relatively low, and the tunability that has practical significance for squeezed light has not been further investigated. Theoretically, the increase of the transmittance of output mirror and the decrease of the intra-cavity loss of the OPO can improve the squeezing level. Here, we use super-polished and optimal coating cavity mirrors to improve the nonlinear process in OPO. We prepare 447.3 nm blue light from 894.6 nm fundamental light by a second harmonic generation cavity (SHG). The SHG is a two-mirror standing-wave cavity with a PPKTP crystal as the nonlinear medium. The power of generated blue laser is 32 mW when the incident infrared power is 120 mW. Using the blue light to pump an OPO, we achieve quadrature squeezed vacuum light at cesium D1 line. The OPO is a two-mirror standing-wave cavity with a PPKTP crystal. The threshold of OPO is reduced to 28 mW. The squeezing level of generated quadrature squeezed vacuum light is increased to 3.3 dB when the pump power is 15 mW. Taking into account the overall detection efficiency, the actual squeezing reaches 5.5 dB. We inject a weak signal beam into the OPO cavity to act as an optical parametric amplifier (OPA), and test the tunability of squeezzed light. The blue light and the squeezed light are tuned by using a low-frequency triangular wave signal to scan the Ti: sapphire laser. Gradually increasing the amplitude of the scanning triangle wave signal, the generated bright squeezed light can be continuously tuned over a range around 80 MHz without losing the stability of the whole system. The generated squeezed light offers the possibility for the efficient coupling between the non-classical source and solid medium in the process of quantum interface.
Stable, low noise, infrared squeezed state tight at 1064 nm is generated by utilizing optical parametric down-conversion (OPDC) technique based on periodically poled KTiOPO 4 in a optical parametric amplifier (OPA) resonator. A non-classical noise reduction of 2.58 dB below the shot noise is observed through balanced homodyne detection. The squeezed state light is used to set up an imaging system for high-resolution imaging, and it is found that the resolution of image based on the amplitude-squeezed light is 1.26 times larger than that of infrared coherent light under the same intensity. The experimental results indicate that squeezed light is an important non-classical light, which can overcome the coherent laser shot-noise, the classical diffraction limit and limit of quantum noise.
Continuous quantum nondemolition (QND) measurements of the amplitude quadrature of a 1064 nm wave are performed with a monolithic dual-port degenerate optical parametric amplifier (OPA). The quality of the measurement is limited in part by the quantum fluctuations carried by the vacuum meter input wave. Improved QND measurements are realized by injecting 3.4 dB amplitude-squeezed light into the meter input port of the OPA. This achieves increased squeezing and correlation of the output signal and meter waves, and both improved operation as a quantum optical tap and as a quantum state preparator. The all-solid-state system was operated for 5 h with high stability.