Interplanetary Network Progress Report

A One-Liter Mercury Ion Clock for Space and Ground Applications

John D. Prestage, Sang‒Ho Chung, Tuan M. Le, M. Beach, Lute Maleki, Robert L. Tjoelker

Published Nov 1, 2003• 0 citations
OpenAlex

Abstract

We describe progress towards the development of a small mercury (Hg+) ion clock suitable for space use. A small clock occupying a 1- to 2-liter volume and producing a stability of 10−12/ τ would significantly advance the state of space-qualified atomic clocks. Based on recent measurements, this technology should produce long-term stability as good as 10−15. I.

Related papers

One-Liter Ion Clock: New Capability For Spaceflight Applications

John D. Prestage, Sang Kun Chung, Thanh Le +2 more

We describe the development of a small Hg+ ion clock suitable for space use. The breadboard physics package is 1-2 liters in volume, produces frequency stability of 10-13/ , and should significantly advance the state of space-qualified atomic clocks.

•Dec 4, 2003•16 citations

Realization of a compact mercury ion microwave clock with frequency stability of 6.3 × 10− 16

Hao Liu, Yi-He Chen, Jian Wang +6 more

The mercury ion microwave clock is considered to be one of the leading candidates for new generation satellite navigation atomic clocks due to its excellent long-term frequency stability, extremely low frequency drift rate, high reliability and good potential for miniaturization. In recent years, the performance and maturity of the space mercury ion microwave clock have improved rapidly, and the reported long-term stability results are mostly in low 10 − 15 level. In this article, we present a compact laboratory prototype of mercury ion microwave clock aiming to spaceborne applications with the long-term stability below 1 × 10 − 15 . By regulating the physical effects contributing to the clock transition frequency shifts, the clock maintains a white frequency noise Allan deviation of 2.8 × 10 − 13 / τ 1/2 with the averaging time τ over 10 5 s and achieves the long-term stability of 6.3 × 10 − 16 for averaging times of 200,000 s. The space mercury ion microwave clock with such level performance will benefit the Global Navigation Satellite Systems and a wide range of space science and missions.

Scientific Reports•Dec 15, 2025•3 citations

DSAC and next generation high stability, long life trapped mercury ion frequency standards

Eric A. Burt, Todd Ely, Robert L. Tjoelker

Abstract The methods of trapping and cooling of atoms and ions have been transformative for atomic clocks due to the reduction, and in some cases elimination, of major systematic frequency shifts. Continuously operating atomic clocks based on trapped mercury ions have existed for decades but until recently have been restricted to terrestrial applications. The recently completed Deep Space Atomic Clock (DSAC) mission demonstrated the first trapped ion clock operation in space. Here we review DSAC as well as follow-on improvements towards the realization of high stability, long life Hg ion atomic clocks for foreseen ground and flight application.

Journal of Physics Conference Series•Nov 1, 2024•4 citations

Performance of Micro Mercury Trapped Ion Clock

Thai M. Hoang, Sang Kun Chung, Thanh Le +4 more

Trapped mercury ion is a promising candidate for portable and operational atomic clocks. It operates at the 40.5GHz ground state hyperfine transition of 199Hg ions. Mercury ions are confined in a linear RF trap, buffer-gas cooled, with a long ion storage lifetime in an ultra-high vacuum enclosure without an active pump. The clock transition is optically-pumped and detected with a Hg discharge lamp without need of a laser light source. This approach has proven to provide simplicity in design and implementation and robustness in operation. In this paper, we report our recently effort on developing a micro and low-power mercury trapped ion clock in the DARPA ACES program. In a 5 mm x 10 mm linear trap (0.25 cc), we have achieved the clock fractional frequency stability of .7 × 10-12τ-1/2and reached down to 7 × 10-14after 1000 seconds of averaging. We will discuss the clock performance under different conditions and implications toward a micro mercury trapped ion clock with low power and high stability.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•10 citations

Compact Microwave Mercury Ion Clock for Deep-Space Applications

John D. Prestage, Sang Kun Chung, Lawrence Lim +1 more

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability ~1-2times10-13at 1 second, averaging to 10-15at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2times10-13second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly two years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow a ~400degC tube bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved. We use neon as a buffer gas with 2-3 times less pressure induced frequency pulling than helium and, being heavier, negligible diffusion losses will occur over the operation lifetime.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2007•9 citations

Demonstration of a Mercury Trapped Ion Clock Prototype

Thai M. Hoang, Sang Kun Chung, Thanh Le +8 more

In this work, we report a prototype of micro mercury trapped ion atomic clock. All the clock components have been packaged and demonstrated in a magnetic shield box of 4 liters. The prototype clock shows promising performance with a short-term fractional frequency instability below 10−11τ−12and can reach the 10−14-instability level after a day of averaging. The prototype clock is capable of reaching the10−15-fractional frequency instability range. Our demonstration of the integrated clock prototype paves the way for further SWaP reduction and maturation.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 7, 2021•3 citations
We describe progress towards the development of a small mercury (Hg+) ion clock suitable for space use. A small clock occupying a 1- to 2-liter volume and producing a stability of 10−12/ τ would significantly advance the state of space-qualified atomic clocks. Based on recent measurements, this technology should produce long-term stability as good as 10−15. I.
The mercury ion microwave clock is considered to be one of the leading candidates for new generation satellite navigation atomic clocks due to its excellent long-term frequency stability, extremely low frequency drift rate, high reliability and good potential for miniaturization. In recent years, the performance and maturity of the space mercury ion microwave clock have improved rapidly, and the reported long-term stability results are mostly in low 10 − 15 level. In this article, we present a compact laboratory prototype of mercury ion microwave clock aiming to spaceborne applications with the long-term stability below 1 × 10 − 15 . By regulating the physical effects contributing to the clock transition frequency shifts, the clock maintains a white frequency noise Allan deviation of 2.8 × 10 − 13 / τ 1/2 with the averaging time τ over 10 5 s and achieves the long-term stability of 6.3 × 10 − 16 for averaging times of 200,000 s. The space mercury ion microwave clock with such level performance will benefit the Global Navigation Satellite Systems and a wide range of space science and missions.
Abstract The methods of trapping and cooling of atoms and ions have been transformative for atomic clocks due to the reduction, and in some cases elimination, of major systematic frequency shifts. Continuously operating atomic clocks based on trapped mercury ions have existed for decades but until recently have been restricted to terrestrial applications. The recently completed Deep Space Atomic Clock (DSAC) mission demonstrated the first trapped ion clock operation in space. Here we review DSAC as well as follow-on improvements towards the realization of high stability, long life Hg ion atomic clocks for foreseen ground and flight application.
Trapped mercury ion is a promising candidate for portable and operational atomic clocks. It operates at the 40.5GHz ground state hyperfine transition of 199Hg ions. Mercury ions are confined in a linear RF trap, buffer-gas cooled, with a long ion storage lifetime in an ultra-high vacuum enclosure without an active pump. The clock transition is optically-pumped and detected with a Hg discharge lamp without need of a laser light source. This approach has proven to provide simplicity in design and implementation and robustness in operation. In this paper, we report our recently effort on developing a micro and low-power mercury trapped ion clock in the DARPA ACES program. In a 5 mm x 10 mm linear trap (0.25 cc), we have achieved the clock fractional frequency stability of .7 × 10-12τ-1/2and reached down to 7 × 10-14after 1000 seconds of averaging. We will discuss the clock performance under different conditions and implications toward a micro mercury trapped ion clock with low power and high stability.
We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability ~1-2times10-13at 1 second, averaging to 10-15at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2times10-13second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly two years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow a ~400degC tube bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved. We use neon as a buffer gas with 2-3 times less pressure induced frequency pulling than helium and, being heavier, negligible diffusion losses will occur over the operation lifetime.
In this work, we report a prototype of micro mercury trapped ion atomic clock. All the clock components have been packaged and demonstrated in a magnetic shield box of 4 liters. The prototype clock shows promising performance with a short-term fractional frequency instability below 10−11τ−12and can reach the 10−14-instability level after a day of averaging. The prototype clock is capable of reaching the10−15-fractional frequency instability range. Our demonstration of the integrated clock prototype paves the way for further SWaP reduction and maturation.