Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Towards an optical frequency standard based on a single Ca/sup +/ ion in a miniature trap

Martina Knoop, Mustapha Said Herbane, M. Houssin, M. Vedel, F. Vedel

Published Aug 29, 2005• 0 citations
Publisher

Abstract

Summary form only given. Among the ions proposed for a frequency standard in the optical domain, Ca/sup +/ is one of the most favorable candidates due to its wavelengths accessible with all-solid-state laser systems. This allows to imagine an ultimate experimental setup being simple and compact. The 4S/sub 1/2/-3D/sub 5/2/ electric quadrupole transition at 729 nm with a natural linewidth below 1 Hz serves as clock transition, while laser cooling on one of the resonance lines is carried out at 397 nm. To obtain the small spectral linewidths necessary for a frequency standard performance, it is essential to reduce the residual Doppler broadening caused by the RF heating in the Paul trap. The first-order Doppler broadening of a single ion can be eliminated in the Lamb-Dicke regime where the ion's amplitude of motion is inferior to the emitted wavelength. The main condition for the access of this frequency modulation regime is a high motional frequency of the trapped ion. This is more easily obtained in a low capacitance device and thus traps with reduced dimensions are required. We have set up a miniature ion trap of the Paul-Straubel-type. The stored ions are observed by a photomultiplier in the photon-counting mode as well as by an intensified CCD camera, permitting the visualization of their spatial behavior. Laser cooling of the Ca/sup +/ ions is carried out on the 4S/sub 1/2/-4P/sup 1/2/ resonance line at 397 nm. Progress on the characterization of the trapped single ion as well as on the generation of the involved wavelengths exclusively by solid-state lasers is reported.

DOI
10.1109/iqec.2000.907910

Related papers

Probing Ca/sup +/ ions in a miniature trap

Martina Knoop, Mustapha Said Herbane, M. Houssin +3 more

The electric quadrupole transition of confined Ca/sup +/ ions has been proposed as a frequency standard in the visible domain. To access metrologic conditions, we have built a cylindrical miniature trap, allowing to obtain high frequencies of motion and preparing the access to the Lamb-Dicke regime where the first order Doppler broadening is suppressed. Laser cooling and interrogation of the confined ions require lasers at 397 nm and at 729 nm. We propose the generation of these wavelengths using multimode laser diodes and a frequency-doubling set-up.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•0 citations

Indium single ion optical frequency standard

T. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 13, 2002•3 citations

Single ion optical frequency standard

Jonas Bergquist, Wayne M. Itano, David J. Wineland +3 more

Experimental research toward the realization of an optical frequency standard of high accuracy is briefly reviewed. The studies concentrated on single, laser-cooled ions since they offer several attractive features for the achievement of high accuracy. These features include long storage time which eliminates transit-time broadening, confinement that is nearly nonperturbative to the internal level structure of the ion, laser-cooling that reduces motional shifts to small values, and electron-shelving whereby transitions to long-lived states can be detected with unit probability. The authors studied spectroscopically the electric-quadrupole allowed transition at 282 nm in a single, laser-cooled /sup 199/Hg/sup +/ ion stored in an RF Paul trap with extremely high resolution. The measured linewidth is limited by the spectral purity of the laser to about 80 Hz. Possible improvements and future directions are discussed.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 1, 1991•8 citations

Quadrupole Transition Spectrum Measurement of Single Ca+ Ions Toward Optical Frequency Standards

Kensuke Matsubara, Ying Li, Kyoya Fukuda +6 more

The National Institute of Information and Communications Technology in Japan is proceeding with development of an optical frequency standard using an electric quadrupole transition of Ca+ ions in a small radio-frequency trap. The single, trapped 40Ca+ ions are laser cooled to a temperature of <10 mK using extended-cavity diode lasers at 397 nm and 866 nm. In order to measure the electric quadrupole transition, the linewidth of the clock laser diode at 729 nm is reduced to ~66 Hz using an ultra-low-expansion (ULE) cavity. We observed the electric quadrupole transition with a linewidth of ~600 kHz, together with the ionic motional sidebands. We are also developing optical frequency combs without photonic fibers broadening the spectrum. The experimental is now improved in order to observe the narrower linewidth of the quadrupole transition.

•Dec 9, 2006•0 citations

Indium single-ion optical frequency standard

Thomas P. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

Single laser-cooled ions in radiofrequency traps can serve as the basis for highly stable optical frequency standards. Here we present recent results on In+, using the 1S0 yields 3P0 line at 236.5 nm wavelength as the clock transition. This resonance has a natural linewidth of only 0.82 Hz and systematic shifts should be controllable at the mHz level. A single indium ion is stored in a miniature Paul- Straubel trap and laser cooled to a temperature of about 100 (mu) K. The clock transition is excited using a frequency quadrupled 946 nm Nd:YAG laser. A fractional resolution of 1.3 (DOT) 10-13 has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute optical frequency of the clock transition has been measured with an uncertainty being less than 3 (DOT) 10-13 using a frequency chain and a methane-stabilized HeNe laser that was calibrated with a cesium clock.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2001•0 citations

Optical frequency standard based on a single 40Ca+

Kelin Gao

Research on the development of the optical frequency standard based on trapped and cold 40 Ca + with the 4s 2 S 1/2 -3d 2 D 5/2 clock transition at 729 nm is reported. A single calcium ion was trapped and laser cooled in the Paul trap and stay in trap for more than 15 days. The linewidth of a 729 nm laser was reduced to less than 10 Hz by locking to a cavity for longer than 50 hours uninterruptedly. The overall systematic uncertainty of the clock transition has been characterized to be better than 6.5×10 −16 . The absolute frequency of the clock transition was measured at 10 −15 level using an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the global positioning system (GPS). The frequency value was 411042129776393.0(1.6) Hz after the correction of the systematic shifts.

Chinese Science Bulletin•Mar 1, 2013•9 citations
Summary form only given. Among the ions proposed for a frequency standard in the optical domain, Ca/sup +/ is one of the most favorable candidates due to its wavelengths accessible with all-solid-state laser systems. This allows to imagine an ultimate experimental setup being simple and compact. The 4S/sub 1/2/-3D/sub 5/2/ electric quadrupole transition at 729 nm with a natural linewidth below 1 Hz serves as clock transition, while laser cooling on one of the resonance lines is carried out at 397 nm. To obtain the small spectral linewidths necessary for a frequency standard performance, it is essential to reduce the residual Doppler broadening caused by the RF heating in the Paul trap. The first-order Doppler broadening of a single ion can be eliminated in the Lamb-Dicke regime where the ion's amplitude of motion is inferior to the emitted wavelength. The main condition for the access of this frequency modulation regime is a high motional frequency of the trapped ion. This is more easily obtained in a low capacitance device and thus traps with reduced dimensions are required. We have set up a miniature ion trap of the Paul-Straubel-type. The stored ions are observed by a photomultiplier in the photon-counting mode as well as by an intensified CCD camera, permitting the visualization of their spatial behavior. Laser cooling of the Ca/sup +/ ions is carried out on the 4S/sub 1/2/-4P/sup 1/2/ resonance line at 397 nm. Progress on the characterization of the trapped single ion as well as on the generation of the involved wavelengths exclusively by solid-state lasers is reported.
The electric quadrupole transition of confined Ca/sup +/ ions has been proposed as a frequency standard in the visible domain. To access metrologic conditions, we have built a cylindrical miniature trap, allowing to obtain high frequencies of motion and preparing the access to the Lamb-Dicke regime where the first order Doppler broadening is suppressed. Laser cooling and interrogation of the confined ions require lasers at 397 nm and at 729 nm. We propose the generation of these wavelengths using multimode laser diodes and a frequency-doubling set-up.
A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.
Experimental research toward the realization of an optical frequency standard of high accuracy is briefly reviewed. The studies concentrated on single, laser-cooled ions since they offer several attractive features for the achievement of high accuracy. These features include long storage time which eliminates transit-time broadening, confinement that is nearly nonperturbative to the internal level structure of the ion, laser-cooling that reduces motional shifts to small values, and electron-shelving whereby transitions to long-lived states can be detected with unit probability. The authors studied spectroscopically the electric-quadrupole allowed transition at 282 nm in a single, laser-cooled /sup 199/Hg/sup +/ ion stored in an RF Paul trap with extremely high resolution. The measured linewidth is limited by the spectral purity of the laser to about 80 Hz. Possible improvements and future directions are discussed.>
The National Institute of Information and Communications Technology in Japan is proceeding with development of an optical frequency standard using an electric quadrupole transition of Ca+ ions in a small radio-frequency trap. The single, trapped 40Ca+ ions are laser cooled to a temperature of <10 mK using extended-cavity diode lasers at 397 nm and 866 nm. In order to measure the electric quadrupole transition, the linewidth of the clock laser diode at 729 nm is reduced to ~66 Hz using an ultra-low-expansion (ULE) cavity. We observed the electric quadrupole transition with a linewidth of ~600 kHz, together with the ionic motional sidebands. We are also developing optical frequency combs without photonic fibers broadening the spectrum. The experimental is now improved in order to observe the narrower linewidth of the quadrupole transition.
Single laser-cooled ions in radiofrequency traps can serve as the basis for highly stable optical frequency standards. Here we present recent results on In+, using the 1S0 yields 3P0 line at 236.5 nm wavelength as the clock transition. This resonance has a natural linewidth of only 0.82 Hz and systematic shifts should be controllable at the mHz level. A single indium ion is stored in a miniature Paul- Straubel trap and laser cooled to a temperature of about 100 (mu) K. The clock transition is excited using a frequency quadrupled 946 nm Nd:YAG laser. A fractional resolution of 1.3 (DOT) 10-13 has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute optical frequency of the clock transition has been measured with an uncertainty being less than 3 (DOT) 10-13 using a frequency chain and a methane-stabilized HeNe laser that was calibrated with a cesium clock.
Research on the development of the optical frequency standard based on trapped and cold 40 Ca + with the 4s 2 S 1/2 -3d 2 D 5/2 clock transition at 729 nm is reported. A single calcium ion was trapped and laser cooled in the Paul trap and stay in trap for more than 15 days. The linewidth of a 729 nm laser was reduced to less than 10 Hz by locking to a cavity for longer than 50 hours uninterruptedly. The overall systematic uncertainty of the clock transition has been characterized to be better than 6.5×10 −16 . The absolute frequency of the clock transition was measured at 10 −15 level using an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the global positioning system (GPS). The frequency value was 411042129776393.0(1.6) Hz after the correction of the systematic shifts.