Chinese Physics B

Microwave interrogation cavity for the rubidium space cold atom clock

Wei Ren, Yuan-Ci Gao, Tang Li, Desheng Lü, Liang Liu

Published Jun 1, 2016• 3 citations
Publisher

Abstract

The performance of space cold atom clocks (SCACs) should be improved thanks to the microgravity environment in space. The microwave interrogation cavity is a key element in a SCAC. In this paper, we develop a microwave interrogation cavity especially for the rubidium SCAC. The interrogation cavity has two microwave interaction zones with a single feed-in source, which is located at the center of the cavity for symmetric coupling excitation and to ensure that the two interaction zones are in phase. The interrogation cavity has a measured resonance frequency of 6.835056471 GHz with a loaded quality factor of nearly 4200, which shows good agreement with simulation results. We measure the Rabi frequency of the clock transition of the rubidium atom in each microwave interaction zone, and subsequently demonstrate that the distributions of the magnetic field in the two interaction zones are the same and meet all requirements of the rubidium SCAC.

DOI
10.1088/1674-1056/25/6/060601

Related papers

Initial Tests of a Rubidium Space Cold Atom Clock

Lin Li, Qiuzhi Qu, Bin Wang +9 more

We report the initial test results of a rubidium ( 87 Rb) space cold atom clock (SCAC). The space-qualified 87 Rb SCAC is composed of the physical package, the optical bench, the microwave synthesizer and the control electronics. After the system is integrated, about 10 8 87 Rb cold atoms are captured by magneto-optical trap. The linewidth of the Ramsey fringe is about 10 Hz for the free evolution time of 50 ms on the ground, and the signal-to-noise ratio is measured to be larger than 300. We demonstrate a good medium-term fractional frequency stability of 1.5 × 10 −14 @1000 s in the closed-loop operation on the ground. The main effects of the noise on the stability are also presented, and the optimized operating parameter is analyzed for the operation of SCAC in the microgravity environment.

Chinese Physics Letters•Jun 1, 2016•9 citations

Physics package based on intracavity laser cooling 87Rb atoms for space cold atom microwave clock

Siminda 思敏达 Deng 邓, Wei 伟 Ren 任, Jingfeng Xiang +9 more

Abstract This article proposes a new physics package to enhance the frequency stability of the space cold atom clock with the advantages of a microgravity environment. Clock working processes, including atom cooling, atomic state preparation, microwave interrogation, and transition probability detection, are integrated into the cylindrical microwave cavity to achieve a high-performance and compact physics package for the space cold atom clock. We present the detailed design and ground-test results of the cold atom clock physics package in this article, which demonstrates a frequency stability of 1.2 × 10−12 τ −1/2 with a Ramsey linewidth of 12.5 Hz, and a better performance is predicted with a 1 Hz or a narrower Ramsey linewidth in microgravity environment. The miniaturized cold atom clock based on intracavity cooling has great potential for achieving space high-precision time-frequency reference in the future.

Chinese Physics B•May 15, 2024•4 citations

Design Concept for the Microwave Interrogation Structure in PARCS

G.J. Dick, William M. Klipstein, Thomas P. Heavner +1 more

In this paper we describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the primary atomic reference clock in space (PARCS) experiment. The PARCS standard uses balls of cold atoms launched in a pulsed beam configuration. The microwave interrogation will take place in two independent high-Q (/spl sim/20,000) cavities operated in the TE/sub 011/ mode. The cavities will be operated off resonance by several linewidths, with a resonant coupling structure delivering the microwave to the two cavities. One persistent problem related to the end-to-end phase shift has been the extreme temperature sensitivity of the phase of inside the cavities to that just outside the cavities. The end-to-end phase shift must ultimately be known to around 3 microradians, and stable long enough to allow measurement of the shift as well as to allow normal clock operation. Operating the cavities off resonance reduces this sensitivity more strongly than reducing the cavity Q.

•Dec 5, 2002•0 citations

Cold atom microwave clock based on intracavity cooling in China space station

Siminda Deng, Wei Ren, Jingfeng Xiang +9 more

Abstract Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.

npj Microgravity•Jun 6, 2024•9 citations

Scheme for a compact cold-atom clock based on diffuse laser cooling in a cylindrical cavity

Peng Liu, Yan-Ling Meng, Jinyin Wan +5 more

We present a scheme for a compact rubidium cold-atom clock which performs diffuse light cooling, microwave interrogation, and detection of the clock signal in a cylindrical microwave cavity. The diffuse light is produced by laser light reflection at the inner surface of the microwave cavity. The pattern of the injected laser beams is specially designed to accumulate the majority of the cold atoms in the center of the microwave cavity. Microwave interrogation of the cold atoms in the cavity leads to Ramsey fringes, which have a linewidth of $24.5$ Hz with a contrast of $95.6%$ when the free evolution time is 20 ms. Recently, a frequency stability of $7.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}\phantom{\rule{0.28em}{0ex}}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved. The scheme of this physical package can largely reduce the cold-atom clock complexity and increase clock performance.

arXiv:1509.07650•Physical Review A•Dec 3, 2015•43 citations

Measuring microwave cavity response using atomic Rabi resonances

Fuyu Sun, Jie Ma, Qingsong Bai +3 more

In this letter, an atom-based approach for measuring the microwave (MW) cavity response (including cavity frequency and Q-factor) is presented, which utilizes a MW magnetic field detection technique based on atomic Rabi resonances. We first identify the Rabi resonances on seven π transitions in Cs atoms and demonstrate their uses in continuously frequency-tunable field detectors. With the atom-based field detectors, we then indicate the possibility of reconstructing the MW cavity response by measuring the MW frequency-dependent Rabi frequency (i.e., MW field strength) inside the cavity. To demonstrate this approach, we measured the response curves of a 9.2-GHz cavity and a cavity resonating at 8.3 GHz and 9.7 GHz using π transitions and σ transitions, respectively. We compared the results measured by our approach with those measured by Vector Networker Analyzer and obtained good agreement. From such atom-based, SI-traceable measurements, the MW cavity response can be linked directly to the Rabi frequency, which could be referred to an atomic clock.

Applied Physics Letters•Jul 31, 2017•41 citations
The performance of space cold atom clocks (SCACs) should be improved thanks to the microgravity environment in space. The microwave interrogation cavity is a key element in a SCAC. In this paper, we develop a microwave interrogation cavity especially for the rubidium SCAC. The interrogation cavity has two microwave interaction zones with a single feed-in source, which is located at the center of the cavity for symmetric coupling excitation and to ensure that the two interaction zones are in phase. The interrogation cavity has a measured resonance frequency of 6.835056471 GHz with a loaded quality factor of nearly 4200, which shows good agreement with simulation results. We measure the Rabi frequency of the clock transition of the rubidium atom in each microwave interaction zone, and subsequently demonstrate that the distributions of the magnetic field in the two interaction zones are the same and meet all requirements of the rubidium SCAC.
We report the initial test results of a rubidium ( 87 Rb) space cold atom clock (SCAC). The space-qualified 87 Rb SCAC is composed of the physical package, the optical bench, the microwave synthesizer and the control electronics. After the system is integrated, about 10 8 87 Rb cold atoms are captured by magneto-optical trap. The linewidth of the Ramsey fringe is about 10 Hz for the free evolution time of 50 ms on the ground, and the signal-to-noise ratio is measured to be larger than 300. We demonstrate a good medium-term fractional frequency stability of 1.5 × 10 −14 @1000 s in the closed-loop operation on the ground. The main effects of the noise on the stability are also presented, and the optimized operating parameter is analyzed for the operation of SCAC in the microgravity environment.
Abstract This article proposes a new physics package to enhance the frequency stability of the space cold atom clock with the advantages of a microgravity environment. Clock working processes, including atom cooling, atomic state preparation, microwave interrogation, and transition probability detection, are integrated into the cylindrical microwave cavity to achieve a high-performance and compact physics package for the space cold atom clock. We present the detailed design and ground-test results of the cold atom clock physics package in this article, which demonstrates a frequency stability of 1.2 × 10−12 τ −1/2 with a Ramsey linewidth of 12.5 Hz, and a better performance is predicted with a 1 Hz or a narrower Ramsey linewidth in microgravity environment. The miniaturized cold atom clock based on intracavity cooling has great potential for achieving space high-precision time-frequency reference in the future.
In this paper we describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the primary atomic reference clock in space (PARCS) experiment. The PARCS standard uses balls of cold atoms launched in a pulsed beam configuration. The microwave interrogation will take place in two independent high-Q (/spl sim/20,000) cavities operated in the TE/sub 011/ mode. The cavities will be operated off resonance by several linewidths, with a resonant coupling structure delivering the microwave to the two cavities. One persistent problem related to the end-to-end phase shift has been the extreme temperature sensitivity of the phase of inside the cavities to that just outside the cavities. The end-to-end phase shift must ultimately be known to around 3 microradians, and stable long enough to allow measurement of the shift as well as to allow normal clock operation. Operating the cavities off resonance reduces this sensitivity more strongly than reducing the cavity Q.
Abstract Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.
We present a scheme for a compact rubidium cold-atom clock which performs diffuse light cooling, microwave interrogation, and detection of the clock signal in a cylindrical microwave cavity. The diffuse light is produced by laser light reflection at the inner surface of the microwave cavity. The pattern of the injected laser beams is specially designed to accumulate the majority of the cold atoms in the center of the microwave cavity. Microwave interrogation of the cold atoms in the cavity leads to Ramsey fringes, which have a linewidth of 24.524.524.5 Hz with a contrast of 95.695.6%95.6 when the free evolution time is 20 ms. Recently, a frequency stability of $7.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}\phantom{\rule{0.28em}{0ex}}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved. The scheme of this physical package can largely reduce the cold-atom clock complexity and increase clock performance.
In this letter, an atom-based approach for measuring the microwave (MW) cavity response (including cavity frequency and Q-factor) is presented, which utilizes a MW magnetic field detection technique based on atomic Rabi resonances. We first identify the Rabi resonances on seven π transitions in Cs atoms and demonstrate their uses in continuously frequency-tunable field detectors. With the atom-based field detectors, we then indicate the possibility of reconstructing the MW cavity response by measuring the MW frequency-dependent Rabi frequency (i.e., MW field strength) inside the cavity. To demonstrate this approach, we measured the response curves of a 9.2-GHz cavity and a cavity resonating at 8.3 GHz and 9.7 GHz using π transitions and σ transitions, respectively. We compared the results measured by our approach with those measured by Vector Networker Analyzer and obtained good agreement. From such atom-based, SI-traceable measurements, the MW cavity response can be linked directly to the Rabi frequency, which could be referred to an atomic clock.