Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Ultra-high gradient superradiant amplification in the wake of an intense laser pulse

J. M. Cole, M. J. V. Streeter, N. Lopes, Kristjan Põder, Jonathan Wood, N. P. Dover, Michael S. Bloom, A. Döpp, W. Schumaker, Chris D. Murphy, G. Sarri, Matt Zepf, Alexander G. R. Thomas, Karl M. Krushelnick, Stuart P. D. Mangles, Z. Najmudin

Published Nov 4, 2016• 0 citations
OpenAlex

Related papers

Amplification characteristics of N2+ lasing at multiple wavelengths generated by polarization-modulated femtosecond laser fields

Shu‐Ting Wu, Qian Gao, Yihong Huang +4 more

Multiple gain routes complicate the amplification behaviors of N2+ lasing. A direct comparison of the amplification processes of various lasing lines of N2+ is still lacking to date, mainly because the efficient generation of different lasing lines requires different experimental conditions. In this work, to overcome the limitation, we use an intense polarization-modulated femtosecond laser pulse to simultaneously produce high-intensity N2+ lasing signals at 391 nm and 428 nm, permitting us readily performing their time-domain characterizations. Our results show that the primary amplification of 428-nm lasing is always retarded by a few picoseconds with respect to the probe pulse while the amplification of 391-nm lasing can be basically completed within the probe pulse duration at a relatively high gas pressure, and besides, the time duration of the former sustains several times longer than that of the latter. These observations indicate the non-negligible contribution of the initial electronic coherence established by the pump laser, apart from the external triggering pulse. For the 391-nm lasing, the seed amplification and superradiance can fiercely interplay within the probe pulse duration. However, for the 428-nm lasing, its amplification is in essence Raman-assisted superfluorescence due to the lacking of the initial electronic coherence and a direct triggering pulse. Our findings not only shed light on the physics of N2+ lasing but also promote the relevant studies on the collective emissions in the cascaded multi-level molecular ion system.

Optics Express•Aug 2, 2024•1 citation

Superradiant amplification in an optically dense gas

Jamal T. Manassah, Barry M. Gross

Optics Communications•Nov 1, 1997•25 citations

Toward quantum-noise-limited interferometric measurements of optical nonlinearity in vacuum

Ali Aras, Adrien E. Kraych, Xavier Sarazin +3 more

Quantum Electrodynamics predicts that the vacuum must behave as a nonlinear optical medium: the vacuum optical index should increase when it is stressed by intense electromagnetic fields. The DeLLight (Deflection of Light by Light) project aims to measure it by using intense and ultra-short laser pulses. The experiment uses a Sagnac interferometer to amplify the tiny deflection signal of a low-intensity probe pulse crossing the vacuum refractive-index gradient produced by an external high-intensity pump pulse. The measurement of the amplified signal by a CCD camera requires a high spatial resolution, which is limited by the ultimate quantum noise of the CCD. However, interferometric phase noise induced by the mechanical vibrations of the interferometer is also amplified and degrades spatial resolution. To overcome this, we propose a new method named High-Frequency Phase Noise Suppression (HFPNS), based on the addition of a delayed replica (5 ns) of the probe pulse. The delayed pulse, which is not affected by the pump but is subject to the same vibration noise, enables offline subtraction of correlated phase noise. In this work, we present an experimental proof-of-concept on a prototype interferometer operating with a limited amplification factor ($\mathcal{A}\simeq25$), about 10 times smaller than the required value of the final experiment. We have succeeded in reducing phase noise by a factor of 40, resulting in a residual noise level 2.3 times higher than the expected quantum noise. The residual noise is linked to delay-line instabilities and incident beam pointing fluctuations present during these tests. This result validates HFPNS as a robust method for future quantum-noise-limited interferometric measurements of vacuum optical nonlinearity, though additional stabilization and higher interferometric amplification are still needed.

physics.opticsCross-listedarXiv:2602.10896•Physical Review A•Feb 12, 2026•0 citations

Effects of different broadening mechanisms on pulse amplification in the superradiant regime

Jamal T. Manassah, Barry M. Gross

Optics Communications•Dec 1, 1994•4 citations

Statistical simulation of many-level system pulse pumping by high-intensity laser radiation

Vladimir I. Denisov, Alex Kourbatov

In this work the method of statistical simulation allowing someone to calculate an interaction of laser pulse with nonlinear absorbing many-level medium when the time duration of pulse is equal to longitudinal characteristic relaxation time is suggested and realized. Two problems were solved by this method. The first problem was the one of laser energy storage on the metastable level of medium atoms. The space and time characteristics of this inverted medium of plane geometry were calculated. The amplification coefficient of forbidden transition versus different parameters of this problem was obtained. The second problem was the calculation of many-steps selective photoionization of the atomic beam. Under specific conditions a superradiance had an effect on output of ions during decay of resonant exciting level into metastable level.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 16, 1994•0 citations

Superradiant amplification in an optically dense three-level cascade system

Jamal T. Manassah, Irina Gladkova

Optics Communications•May 1, 2000•10 citations
Multiple gain routes complicate the amplification behaviors of N2+ lasing. A direct comparison of the amplification processes of various lasing lines of N2+ is still lacking to date, mainly because the efficient generation of different lasing lines requires different experimental conditions. In this work, to overcome the limitation, we use an intense polarization-modulated femtosecond laser pulse to simultaneously produce high-intensity N2+ lasing signals at 391 nm and 428 nm, permitting us readily performing their time-domain characterizations. Our results show that the primary amplification of 428-nm lasing is always retarded by a few picoseconds with respect to the probe pulse while the amplification of 391-nm lasing can be basically completed within the probe pulse duration at a relatively high gas pressure, and besides, the time duration of the former sustains several times longer than that of the latter. These observations indicate the non-negligible contribution of the initial electronic coherence established by the pump laser, apart from the external triggering pulse. For the 391-nm lasing, the seed amplification and superradiance can fiercely interplay within the probe pulse duration. However, for the 428-nm lasing, its amplification is in essence Raman-assisted superfluorescence due to the lacking of the initial electronic coherence and a direct triggering pulse. Our findings not only shed light on the physics of N2+ lasing but also promote the relevant studies on the collective emissions in the cascaded multi-level molecular ion system.
Quantum Electrodynamics predicts that the vacuum must behave as a nonlinear optical medium: the vacuum optical index should increase when it is stressed by intense electromagnetic fields. The DeLLight (Deflection of Light by Light) project aims to measure it by using intense and ultra-short laser pulses. The experiment uses a Sagnac interferometer to amplify the tiny deflection signal of a low-intensity probe pulse crossing the vacuum refractive-index gradient produced by an external high-intensity pump pulse. The measurement of the amplified signal by a CCD camera requires a high spatial resolution, which is limited by the ultimate quantum noise of the CCD. However, interferometric phase noise induced by the mechanical vibrations of the interferometer is also amplified and degrades spatial resolution. To overcome this, we propose a new method named High-Frequency Phase Noise Suppression (HFPNS), based on the addition of a delayed replica (5 ns) of the probe pulse. The delayed pulse, which is not affected by the pump but is subject to the same vibration noise, enables offline subtraction of correlated phase noise. In this work, we present an experimental proof-of-concept on a prototype interferometer operating with a limited amplification factor (A≃25\mathcal{A}\simeq25A≃25), about 10 times smaller than the required value of the final experiment. We have succeeded in reducing phase noise by a factor of 40, resulting in a residual noise level 2.3 times higher than the expected quantum noise. The residual noise is linked to delay-line instabilities and incident beam pointing fluctuations present during these tests. This result validates HFPNS as a robust method for future quantum-noise-limited interferometric measurements of vacuum optical nonlinearity, though additional stabilization and higher interferometric amplification are still needed.
In this work the method of statistical simulation allowing someone to calculate an interaction of laser pulse with nonlinear absorbing many-level medium when the time duration of pulse is equal to longitudinal characteristic relaxation time is suggested and realized. Two problems were solved by this method. The first problem was the one of laser energy storage on the metastable level of medium atoms. The space and time characteristics of this inverted medium of plane geometry were calculated. The amplification coefficient of forbidden transition versus different parameters of this problem was obtained. The second problem was the calculation of many-steps selective photoionization of the atomic beam. Under specific conditions a superradiance had an effect on output of ions during decay of resonant exciting level into metastable level.