Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum limited heterodyne detection of 400-840 GHz radiation with superconducting nb tunnel junctions

Gerhard de Lange

Published Jan 1, 1994• 4 citations
OpenAlex

Related papers

Quantum Tunneling and Heterodyne Detection in Superconducting Tunnel Junctions.

N. G. Ugras

•Jan 1, 1993•0 citations

Quantum limited heterodyne detection in superconducting non-linear transmission lines at sub-millimeter wavelengths

Edward Tong, R. Blundell, B. Bumble +2 more

A non-linear superconducting transmission line has been successfully employed in heterodyne detection of sub-millimeter waves. In our experiments an Nb/Al/AlOx/Nb tunnel junction, measuring 0.15×40 μm, with a critical current density of about 2500 A/cm2 is used as a distributed mixer element. We have demonstrated that quantum limited sensitivity can be achieved with this type of device. At 460 GHz, a Y-factor of 2.5 has been recorded, corresponding to a double-side-band receiver noise temperature of 80 K. The double-side-band conversion loss is about 1 dB and the mixer noise temperature is estimated to be 18(±10) K.

Applied Physics Letters•Aug 28, 1995•37 citations

Heterodyne mixing at 70 GHz with superconductor-insulator-superconductor tunnel junctions

Hans J. Hartfuss, K. H. Gundlach

International Journal of Infrared and Millimeter Waves•Sep 1, 1981•9 citations

Heterodyne mixing with Nb tunnel junctions above the gap frequency

Gert J. de Lange, Cornelia E. Honingh, J. J. Kuipers +5 more

The noise and gain of a heterodyne waveguide mixer employing Nb/Al2O3/Nb superconducting tunnel junctions with an on-chip integrated tuning element are measured and analyzed at 680–750 GHz and at 840 GHz. The lowest receiver noise temperatures are 400 K (double side band) at 720 GHz and 1500 K (3000 K including the beam splitter loss) at 840 GHz. We compare data of the pumped I–V curves with the quantum theory of mixing and demonstrate good agreement at frequencies well above the gap frequency.

Applied Physics Letters•May 30, 1994•38 citations

Terahertz heterodyne detection with High-Tc superconducting Josephson junctions

M. Malnou, C. Feuillet-Palma, Luo, Alan +5 more

•Sep 15, 2013•0 citations

Tunable THz source using superconducting tunnel junctions

Faouzi M. Boussaha, A. Féret, Christine Chaumont +2 more

We report on tunable submillimeter-wave radiation sources based on micrometer-sized superconducting tunnel junction arrays optimized within a bandwidth of 350-520 GHz. The arrays consist of 10, 20 and 40 Superconductor-Insulator- Superconductor (SIS) parallel-connected Nb/AlOx/Nb junctions embedded in superconducting microstrip lines. A SIS twin-junction is integrated along with each array to detect output signals. The pumped detector’s I-V characteristic exhibits clearly photon-assisted quasiparticule steps when the arrays are biased upon corresponding Josephson resonances ranging from 370 to 520 GHz.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 24, 2013•0 citations
A non-linear superconducting transmission line has been successfully employed in heterodyne detection of sub-millimeter waves. In our experiments an Nb/Al/AlOx/Nb tunnel junction, measuring 0.15×40 μm, with a critical current density of about 2500 A/cm2 is used as a distributed mixer element. We have demonstrated that quantum limited sensitivity can be achieved with this type of device. At 460 GHz, a Y-factor of 2.5 has been recorded, corresponding to a double-side-band receiver noise temperature of 80 K. The double-side-band conversion loss is about 1 dB and the mixer noise temperature is estimated to be 18(±10) K.
The noise and gain of a heterodyne waveguide mixer employing Nb/Al2O3/Nb superconducting tunnel junctions with an on-chip integrated tuning element are measured and analyzed at 680–750 GHz and at 840 GHz. The lowest receiver noise temperatures are 400 K (double side band) at 720 GHz and 1500 K (3000 K including the beam splitter loss) at 840 GHz. We compare data of the pumped I–V curves with the quantum theory of mixing and demonstrate good agreement at frequencies well above the gap frequency.
We report on tunable submillimeter-wave radiation sources based on micrometer-sized superconducting tunnel junction arrays optimized within a bandwidth of 350-520 GHz. The arrays consist of 10, 20 and 40 Superconductor-Insulator- Superconductor (SIS) parallel-connected Nb/AlOx/Nb junctions embedded in superconducting microstrip lines. A SIS twin-junction is integrated along with each array to detect output signals. The pumped detector’s I-V characteristic exhibits clearly photon-assisted quasiparticule steps when the arrays are biased upon corresponding Josephson resonances ranging from 370 to 520 GHz.