Journal of Physics Conference Series

Portable compact cold atoms clock topology

Rodrigo Duarte Pechoneri, Stella Müller, Cristiane Bueno, Vanderlei Salvador Bagnato, Daniel Varela Magalhães

Published Jul 1, 2016• 3 citations
Publisher

Abstract

The compact frequency standard under development at USP Sao Carlos is a cold atoms system that works with a distributed hardware system principle and temporal configuration of the interrogation method of the atomic sample, in which the different operation steps happen in one place: inside the microwave cavity. This type of operation allows us to design a standard much more compact than a conventional one, where different interactions occur in the same region of the apparatus. In this sense, it is necessary to redefine all the instrumentation associated with the experiment. This work gives an overview of the topology we are adopting for the new system.

DOI
10.1088/1742-6596/733/1/012049

Related papers

Portable compact cold atoms clock topology

Rodrigo Duarte Pechoneri, Stella Müller, Cristiane Bueno +2 more

The compact frequency standard under development at USP Sao Carlos is a cold atoms system that works with a distributed hardware system principle and temporal configuration of the interrogation method of the atomic sample, in which the different operation steps happen in one place: inside the microwave cavity. This type of operation allows us to design a standard much more compact than a conventional one, where different interactions occur in the same region of the apparatus. In this sense, it is necessary to redefine all the instrumentation associated with the experiment. This work gives an overview of the topology we are adopting for the new system.

Anais•Jan 1, 2015•0 citations

Development of a Mobile Atomic Frequency Standard based on Cold Atoms

Stella Müller, Felipe Arduini Otoboni, Jair de Martin +3 more

We have been developing a compact frequency standard based on cold cesium atoms. The atoms are cooled, interrogated during a free expansion and then detected inside a cylindrical microwave cavity. The operation of this experiment is different from conventional cold atoms fountains, since all the steps are sequentially performed in the same place.

Latin America Optics and Photonics Conference•Jan 1, 2012•3 citations

Compact Frequency Standard Based on an Intra-cavity Sample Cold Cesium Atoms

Stella Müller, Daniel Varela Magalhães, Renato Ferracini Alves +1 more

We have demonstrated the possibility for a compact frequency standard based on a sample of cold cesium atoms. In a cylindrical microwave cavity, the atoms are cooled and interrogated during a free expansion and then detected. The operation of this experiment is different from conventional atomic fountains, since all the steps are sequentially performed in the same position of space. In this paper we report the analysis of a Ramsey pattern observed to present a 47 Hz linewidth and a stability of 5x10^-13 for an integration time longer than 100s. Some of the main limitations of the standard are analyzed. This present report demonstrates considerable improvement of our previous work (S. T. Muller et al, J. Opt. Soc. Am. B, v.25, p.909, 2008) where the atoms were in a free space and not inside a microwave cavity.

arXiv:1108.4407•Aug 22, 2011•0 citations

Development of compact laser cooled atomic frequency standards

T. Zanon-Willette, S. Trémine, Stéphane Guérandel +4 more

Two projects of compact cold atom clocks are currently developed: a clock with atoms directly cooled in the microwave cavity and a clock based on coherent population trapping. For each device, different interrogation and detection schemes are evaluated and reported

Conference on Precision Electromagnetic Measurements•Jun 1, 2004•1 citation

Compact frequency standard based on an intracavity sample of cold cesium atoms

Stella Müller, Daniel Varela Magalhães, Renato Ferracini Alves +1 more

We have demonstrated the possibility for a compact frequency standard based on a sample of cold cesium atoms. In a cylindrical microwave cavity, the atoms are cooled and interrogated during a free expansion and then detected. The operation of this experiment is different from conventional atomic fountains since all the steps are sequentially performed in the same position of space. In this paper we report the analysis of a Ramsey pattern observed to present a (47±5) Hz linewidth and a stability of (5±0.5)x10−13τ−1/2 for an integration time longer than 100 s. Some of the main limitations of the standard are analyzed. This present report demonstrates considerable improvement of our previous work [J. Opt. Soc. Am. B25, 909 (2008)JOBPDE0740-322410.1364/JOSAB.25.000909] where the atoms were in a free space and not inside a microwave cavity.

Journal of the Optical Society of America B•Oct 5, 2011•39 citations

High-stability compact atomic clock based on isotropic laser cooling

François-Xavier Esnault, David Holleville, Nicolas Rossetto +2 more

We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved, averaged down to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ after $5\ifmmode\times\else\texttimes\fi{}{10}^{3}$ s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.

Physical Review A•Sep 29, 2010•78 citations
The compact frequency standard under development at USP Sao Carlos is a cold atoms system that works with a distributed hardware system principle and temporal configuration of the interrogation method of the atomic sample, in which the different operation steps happen in one place: inside the microwave cavity. This type of operation allows us to design a standard much more compact than a conventional one, where different interactions occur in the same region of the apparatus. In this sense, it is necessary to redefine all the instrumentation associated with the experiment. This work gives an overview of the topology we are adopting for the new system.
The compact frequency standard under development at USP Sao Carlos is a cold atoms system that works with a distributed hardware system principle and temporal configuration of the interrogation method of the atomic sample, in which the different operation steps happen in one place: inside the microwave cavity. This type of operation allows us to design a standard much more compact than a conventional one, where different interactions occur in the same region of the apparatus. In this sense, it is necessary to redefine all the instrumentation associated with the experiment. This work gives an overview of the topology we are adopting for the new system.
We have demonstrated the possibility for a compact frequency standard based on a sample of cold cesium atoms. In a cylindrical microwave cavity, the atoms are cooled and interrogated during a free expansion and then detected. The operation of this experiment is different from conventional atomic fountains, since all the steps are sequentially performed in the same position of space. In this paper we report the analysis of a Ramsey pattern observed to present a 47 Hz linewidth and a stability of 5x10^-13 for an integration time longer than 100s. Some of the main limitations of the standard are analyzed. This present report demonstrates considerable improvement of our previous work (S. T. Muller et al, J. Opt. Soc. Am. B, v.25, p.909, 2008) where the atoms were in a free space and not inside a microwave cavity.
We have demonstrated the possibility for a compact frequency standard based on a sample of cold cesium atoms. In a cylindrical microwave cavity, the atoms are cooled and interrogated during a free expansion and then detected. The operation of this experiment is different from conventional atomic fountains since all the steps are sequentially performed in the same position of space. In this paper we report the analysis of a Ramsey pattern observed to present a (47±5) Hz linewidth and a stability of (5±0.5)x10−13τ−1/2 for an integration time longer than 100 s. Some of the main limitations of the standard are analyzed. This present report demonstrates considerable improvement of our previous work [J. Opt. Soc. Am. B25, 909 (2008)JOBPDE0740-322410.1364/JOSAB.25.000909] where the atoms were in a free space and not inside a microwave cavity.
We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ has been achieved, averaged down to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ after $5\ifmmode\times\else\texttimes\fi{}{10}^{3}$ s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.