Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

SPIE eBooks

Stimulated Emission Depletion

Tomasz Tkaczyk

Published May 27, 2010• 4 citations
Publisher
DOI
10.1117/3.798239.ch94

Related papers

Stimulated emission depletion microscopy

Janez Štrancar, Jaroslaw Jacak

Institute of Physics eBooks•May 1, 2021•2 citations

Stimulated emission and absorption of radiation and amplification using stimulated emission

Robert P. Davis

•Jan 1, 1961•0 citations

Stimulated Emission

Mathieu Hautefeuille, Juan A. Hernández-Cordero

SPIE eBooks•Nov 9, 2021•0 citations

Influence of fluorescence time characteristics on the spatial resolution of CW-stimulated emission depletion microscopy

Haiyun Qin, Wei Zhao, Chen Zhang +3 more

As one of the most important realizations of stimulated emission depletion (STED) microscopy, the continuous-wave (CW) STED system, constructed by using CW lasers as the excitation and STED beams, has been investigated and developed for nearly a decade. However, a theoretical model of the suppression factors in CW STED has not been well established. In this investigation, the factors that affect the spatial resolution of a CW STED system are theoretically and numerically studied. The full-width-at-half-maximum (FWHM) of a CW STED with a doughnut-shaped STED beam is also reanalyzed. It is found that the suppression function is dominated by the ratio of the local STED and excitation beam intensities. In addition, the FWHM is highly sensitive to both the fluorescence rate (inverse of fluoresce lifetime) and the quenching rate, but insensitive to the rate of vibrational relaxation. For comparison, the suppression function in picosecond STED is only determined by the distribution of the STED beam intensity scaled with the saturation intensity. Our model is highly consistent with published experimental data for evaluating the spatial resolution. This investigation is important in guiding the development of new CW STED systems.

Chinese Physics B•Mar 1, 2018•2 citations

Stimulated emission

Luca Salasnich

Springer eBooks•Jan 1, 2020•0 citations

STED with wavelengths closer to the emission maximum

Giuseppe Vicidomini, Gaël Moneron, Christian Eggeling +2 more

In stimulated emission depletion (STED) nanoscopy the wavelength of the STED beam is usually tuned towards the red tail of the emission maximum of the fluorophore. Shifting the STED wavelength closer to the emission peak, i.e. towards the blue region, favorably increases the stimulated emission cross-section. However, this blue-shifting also increases the probability to excite fluorophores that have remained in their ground state, compromising the image contrast. Here we present a method to exploit the higher STED efficiency of blue-shifted STED beams while maintaining the contrast in the image. The method is exemplified by imaging immunolabeled features in mammalian cells with an up to 3-fold increased STED efficiency compared to that encountered in standard STED nanoscopy implementations.

Optics Express•Feb 16, 2012•105 citations
As one of the most important realizations of stimulated emission depletion (STED) microscopy, the continuous-wave (CW) STED system, constructed by using CW lasers as the excitation and STED beams, has been investigated and developed for nearly a decade. However, a theoretical model of the suppression factors in CW STED has not been well established. In this investigation, the factors that affect the spatial resolution of a CW STED system are theoretically and numerically studied. The full-width-at-half-maximum (FWHM) of a CW STED with a doughnut-shaped STED beam is also reanalyzed. It is found that the suppression function is dominated by the ratio of the local STED and excitation beam intensities. In addition, the FWHM is highly sensitive to both the fluorescence rate (inverse of fluoresce lifetime) and the quenching rate, but insensitive to the rate of vibrational relaxation. For comparison, the suppression function in picosecond STED is only determined by the distribution of the STED beam intensity scaled with the saturation intensity. Our model is highly consistent with published experimental data for evaluating the spatial resolution. This investigation is important in guiding the development of new CW STED systems.
In stimulated emission depletion (STED) nanoscopy the wavelength of the STED beam is usually tuned towards the red tail of the emission maximum of the fluorophore. Shifting the STED wavelength closer to the emission peak, i.e. towards the blue region, favorably increases the stimulated emission cross-section. However, this blue-shifting also increases the probability to excite fluorophores that have remained in their ground state, compromising the image contrast. Here we present a method to exploit the higher STED efficiency of blue-shifted STED beams while maintaining the contrast in the image. The method is exemplified by imaging immunolabeled features in mammalian cells with an up to 3-fold increased STED efficiency compared to that encountered in standard STED nanoscopy implementations.