Feasibility of a stationary micro-SQUID

Jorge Berger

Published Aug 21, 2015• 0 citations
OpenAlex

Abstract

The standard operation of a dc SQUID leads to oscillatory electric fields that emit electromagnetic radiation and can change the state of the measured sample. A stationary SQUID could be advantageous when back action on the measured sample has to be avoided. We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows through the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The influence of thermal noise was estimated. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.

Related papers

Stationary nano-SQUID: theoretical investigation and feasibility analysis

Jorge Berger

The standard operation of a dc SQUID leads to oscillatory electric fields that emit electromagnetic radiation. We estimate the effect that this radiation could have on the measured sample. A stationary SQUID could be advantageous if the oscillation contribution to back action on the measured sample has to be avoided. We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows across the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime, i.e. the densities of normal current and of supercurrent become functions of position only, independent of time. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The influence of thermal noise was estimated. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.

Journal of Physics Condensed Matter•May 30, 2017•3 citations

Proposal for a stationary micro-SQUID

Jorge Berger

We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows through the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.

•Aug 21, 2015•0 citations

Nonlocal superconducting quantum interference device

Taewan Noh, Andrew Kindseth, Venkat Chandrasekhar

Superconducting quantum interference devices (SQUIDs) that incorporate two superconductor/insulator/superconductor (SIS) Josephson junctions in a closed loop form the core of some of the most sensitive detectors of magnetic and electric fields currently available. SQUIDs in these applications are typically operated with a finite voltage which generates microwave radiation through the ac Josephson effect. This radiation may impact the system being measured. We describe here a SQUID in which the Josephson junctions are formed from strips of normal metal (N) in good electrical contact with the superconductor (S). Such SNS SQUIDs can be operated under a finite voltage bias with performance comparable or potentially better than conventional SIS SQUIDs. However, they also permit a mode of operation that is based on the unusual interplay of quasiparticle currents and supercurrents in the normal metal of the Josephson junction. The method allows measurements of the flux dependence of the critical current of the SNS SQUID without applying a finite voltage bias across the SNS junction, enabling sensitive flux detection without generating microwave radiation.

arXiv:2011.06667•Physical review. B./Physical review. B•Aug 4, 2021•12 citations

A micro-SQUID with dispersive readout for magnetic scanning microscopy

Foroughi, F., Mol, J.-M., T. Müller +3 more

We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz, micrometer spatial resolution, and integrated superconducting coils for local application of magnetic fields. The SQUID is operated as a nonlinear oscillator with a flux- and power-dependent resonance frequency. Measurements for device characterization and noise benchmarking were carried out at 4 K. The measured flux noise above 10 kHz at 4 K is 80 nΦ0 Hz−1∕2 at a bandwidth of 200 MHz. Estimations suggest that one can benefit from parametric gain based on inherent nonlinearity of the Josephson junction and reduce the flux noise to 30 nΦ0Hz–1∕2 at 100 mK, which corresponds to 10.6 μBHz–1∕2 for a magnetic moment located at the center of the pickup loop.Measuring the magnetic response of mesoscopic samples or mapping it vs. position for extended systems is effective methods for revealing the fundamental quantum properties of condensed matter systems. Over the past few decades, many advanced magnetic imaging schemes have been developed, including magnetic force microscopy,1 scanning Hall probe microscopy,2 superconducting interference devices (SQUIDs),3,4 and NV center based magnetometry.5 The high sensitivity, low back action, and low power dissipation of SQUIDs make them attractive for many types of low temperature experiments. One classic example is the central role of scanning SQUID microscopy in tests of pairing symmetry of high-Tc cuprate superconductors.6 Other prominent applications are the thermodynamic characteristics of persistent currents in normal metal rings7 and proof of edge states in topological insulators in the quantum spin Hall regime.8A key performance for a SQUID is its flux sensitivity. Parametric amplification has been harnessed in nano-SQUIDs based on aluminum junctions9,10 in order to reduce the flux noise down to 30 nΦ0Hz–1∕2 with a bandwidth exceeding 60 MHz.10 Recent studies on parametric amplifiers and dispersive readout of superconducting qubits also harness the nonlinearity of the Josephson junction to boost sensitivity.11–13In scanning SQUID microscopy, signal sources often behave dipole-like, such as superconducting vortices in mesoscopic dots or currents in mesoscopic rings. Smaller SQUIDs provide better coupling to smaller samples which leads to higher spin sensitivity3,14 as the magnetic field of a dipole decreases with 1/r3. Various approaches have been pursued to reduce the size. The smallest nano-SQUID to date has been fabricated by evaporating Nb or Pb15 onto the apex of a sharp quartz tip reaching a loop diameter of below nm and a spin sensitivity of 0.38 μBHz−1/2 at tens of kHz bandwidth. Compared to such size-optimized devices, micro-SQUIDs fabricated using a standard Nb technique have the advantage of on-chip field coils and modulation coils,14 and can be operated at 4 K allowing for a wide range of applications. However, these come at the cost of larger pick-up loops of a few microns and a resulting poorer spin sensitivity of 200 μBHz−1/2 for a magnetic moment located at the center of the pickup loop.The limitation of large pickup loops was previously only overcome by devices with pickup loops defined by the focused-ion-beam,16 but has recently also been achieved by improvements in lithography and shown to offer better spatial resolution as well.17 Here, we present a scanning micro-SQUID which is based on the same fabrication technology incorporating another major advancement. Our design exploits the parametric amplification based on nonlinearities of the SQUID to boost sensitivity. The combination of a smaller pickup loop and parametric amplification of the signal leads to better spin sensitivity (10.6 μBHz−1/2) and higher bandwidth (200 MHz) compared to traditional DC micro-SQUIDs in which the flux sensitivity is mainly limited by internal dissipation.Our devices were fabricated at Hypres Inc. using planarized Nb/AlOx/Nb trilayer Josephson junction technology, including two planarized Nb layers with approximately 0.8 μm minimum feature size. The SQUID consists of a superconducting ring shunted by one Josephson junction with a designed critical current of 20 μA [Fig. 1(a)]. With this geometry, the SQUID is gradiometric, i.e., the effect of any homogeneous background magnetic field approximately cancels out. The smallest pickup loops implemented have an inner (outer) diameter of 1 μm (2 μm). The superconducting loop is shunted by an on-chip parallel-plate capacitor with amorphous silicon dioxide as dielectric which was designed to have a capacitance of 80 pF. The superconducting loop and the capacitor form a resonator with a flux dependent resonance frequency from 5 to 12 GHz. The pickup loops are placed on opposite corners of the parallel-plate capacitor at a distance of about 450 μm so that one loop can be located in close proximity to the sample while the other is kept far away from it. External fields can be applied to the sample by local single-turn field coils situated around each pickup loop. The field coils are fully integrated into the chip layout and can also be used to bias the SQUID at its most sensitive point. Compared to using additional modulation coils,14 this approach has the advantage of reducing the total device inductance, which leads to a higher sensitivity.18 In a scanning microscope, the field coil at the rear end (away from the sample) can be used to bias the SQUID or operate it in flux feedback such that resulting stray fields will not act on the sample, apart from a weak screening current through the pickup loop. The effective diameter of each coil is 7.5 μm, resulting in a mutual inductance of about 0.34 Φ0/mA (for the smallest pickup loop). The SQUID resonator is connected by an on-chip Z0 = 50 Ω coplanar waveguide (CPW) transmission line to the bonding pads. The two field coils are connected by two smaller CPWs to the bottom edge bonding pads [Fig. 1(c)], ending in two parallel-stripline waveguides running alongside the edges of the capacitor towards the respective field coils. Based on estimations, it should thus be possible to apply high frequency signals of at least several GHz to SQUID and sample.

•Jan 1, 2018•14 citations

Measurements of current noise in DC SQUIDS

John M. Martinis, John L. Clarke

The current noise circulating around the loop of a tunnel junction dc SQUID has been measured as a function of applied flux. The flux noise generated by this current was coupled via a superconducting transformer to a second dc SQUID that was used to measure the noise in a null-balancing configuration. The voltage noise across the SQUID was also measured, using a cooled LC-resonant circuit, and the correlation between the voltage and current noises was determined. The measured values of the noises are in good agreement with values obtained from an analog simulator.

IEEE Transactions on Magnetics•May 1, 1983•21 citations

An all thin-film resistive DC SQUID-a current-controlled oscillator

G.S. Krivoy, H. Koch

An all thin-film resistive SQUID with two Josephson tunnel junctions has been designed, fabricated and studied. As well as the two junctions, this device consists of a low ohmic (1.9*10 -6 Omega ) resistive part connected by superconducting leads to both junctions in a loop with very low ( approximately 10 -11 H) inductance. A direct current flowing through the resistive part fixes the voltage difference between the two Josephson junctions that are additionally fed by a bias current. The voltage difference is converted into a signal frequency that can be picked up from the SQUID with a conversion factor of ( phi o ) -1 =483.6 MHz mu V -1 , defined only by the electron charge and Planck's constant. An output signal level (peak-to-peak) of about 50 mu V has been obtained. The low frequency range (below 100 kHz) of the output signal frequency has been investigated. The possibilities of considerably extending this frequency range are also discussed.

Superconductor Science and Technology•Oct 1, 1992•14 citations
The standard operation of a dc SQUID leads to oscillatory electric fields that emit electromagnetic radiation and can change the state of the measured sample. A stationary SQUID could be advantageous when back action on the measured sample has to be avoided. We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows through the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The influence of thermal noise was estimated. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.
The standard operation of a dc SQUID leads to oscillatory electric fields that emit electromagnetic radiation. We estimate the effect that this radiation could have on the measured sample. A stationary SQUID could be advantageous if the oscillation contribution to back action on the measured sample has to be avoided. We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows across the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime, i.e. the densities of normal current and of supercurrent become functions of position only, independent of time. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The influence of thermal noise was estimated. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.
We study a superconducting loop that encloses a magnetic flux, connected to a superconducting and to a normal electrode, when a fixed electric current between the electrodes flows through the loop. The considered circuit does not contain Josephson junctions. We find that in a very broad range of parameters the current flow converges to a stationary regime. The potential difference between the electrodes depends on the magnetic flux, so that measuring this voltage would provide information on the enclosed flux. The sizes of the voltage and of the power dissipation could be appropriate for the design of a practical fluxmeter. We found narrow ranges of flux at which the voltage varies sharply with the flux.
Superconducting quantum interference devices (SQUIDs) that incorporate two superconductor/insulator/superconductor (SIS) Josephson junctions in a closed loop form the core of some of the most sensitive detectors of magnetic and electric fields currently available. SQUIDs in these applications are typically operated with a finite voltage which generates microwave radiation through the ac Josephson effect. This radiation may impact the system being measured. We describe here a SQUID in which the Josephson junctions are formed from strips of normal metal (N) in good electrical contact with the superconductor (S). Such SNS SQUIDs can be operated under a finite voltage bias with performance comparable or potentially better than conventional SIS SQUIDs. However, they also permit a mode of operation that is based on the unusual interplay of quasiparticle currents and supercurrents in the normal metal of the Josephson junction. The method allows measurements of the flux dependence of the critical current of the SNS SQUID without applying a finite voltage bias across the SNS junction, enabling sensitive flux detection without generating microwave radiation.
We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz, micrometer spatial resolution, and integrated superconducting coils for local application of magnetic fields. The SQUID is operated as a nonlinear oscillator with a flux- and power-dependent resonance frequency. Measurements for device characterization and noise benchmarking were carried out at 4 K. The measured flux noise above 10 kHz at 4 K is 80 nΦ0 Hz−1∕2 at a bandwidth of 200 MHz. Estimations suggest that one can benefit from parametric gain based on inherent nonlinearity of the Josephson junction and reduce the flux noise to 30 nΦ0Hz–1∕2 at 100 mK, which corresponds to 10.6 μBHz–1∕2 for a magnetic moment located at the center of the pickup loop.Measuring the magnetic response of mesoscopic samples or mapping it vs. position for extended systems is effective methods for revealing the fundamental quantum properties of condensed matter systems. Over the past few decades, many advanced magnetic imaging schemes have been developed, including magnetic force microscopy,1 scanning Hall probe microscopy,2 superconducting interference devices (SQUIDs),3,4 and NV center based magnetometry.5 The high sensitivity, low back action, and low power dissipation of SQUIDs make them attractive for many types of low temperature experiments. One classic example is the central role of scanning SQUID microscopy in tests of pairing symmetry of high-Tc cuprate superconductors.6 Other prominent applications are the thermodynamic characteristics of persistent currents in normal metal rings7 and proof of edge states in topological insulators in the quantum spin Hall regime.8A key performance for a SQUID is its flux sensitivity. Parametric amplification has been harnessed in nano-SQUIDs based on aluminum junctions9,10 in order to reduce the flux noise down to 30 nΦ0Hz–1∕2 with a bandwidth exceeding 60 MHz.10 Recent studies on parametric amplifiers and dispersive readout of superconducting qubits also harness the nonlinearity of the Josephson junction to boost sensitivity.11–13In scanning SQUID microscopy, signal sources often behave dipole-like, such as superconducting vortices in mesoscopic dots or currents in mesoscopic rings. Smaller SQUIDs provide better coupling to smaller samples which leads to higher spin sensitivity3,14 as the magnetic field of a dipole decreases with 1/r3. Various approaches have been pursued to reduce the size. The smallest nano-SQUID to date has been fabricated by evaporating Nb or Pb15 onto the apex of a sharp quartz tip reaching a loop diameter of below nm and a spin sensitivity of 0.38 μBHz−1/2 at tens of kHz bandwidth. Compared to such size-optimized devices, micro-SQUIDs fabricated using a standard Nb technique have the advantage of on-chip field coils and modulation coils,14 and can be operated at 4 K allowing for a wide range of applications. However, these come at the cost of larger pick-up loops of a few microns and a resulting poorer spin sensitivity of 200 μBHz−1/2 for a magnetic moment located at the center of the pickup loop.The limitation of large pickup loops was previously only overcome by devices with pickup loops defined by the focused-ion-beam,16 but has recently also been achieved by improvements in lithography and shown to offer better spatial resolution as well.17 Here, we present a scanning micro-SQUID which is based on the same fabrication technology incorporating another major advancement. Our design exploits the parametric amplification based on nonlinearities of the SQUID to boost sensitivity. The combination of a smaller pickup loop and parametric amplification of the signal leads to better spin sensitivity (10.6 μBHz−1/2) and higher bandwidth (200 MHz) compared to traditional DC micro-SQUIDs in which the flux sensitivity is mainly limited by internal dissipation.Our devices were fabricated at Hypres Inc. using planarized Nb/AlOx/Nb trilayer Josephson junction technology, including two planarized Nb layers with approximately 0.8 μm minimum feature size. The SQUID consists of a superconducting ring shunted by one Josephson junction with a designed critical current of 20 μA [Fig. 1(a)]. With this geometry, the SQUID is gradiometric, i.e., the effect of any homogeneous background magnetic field approximately cancels out. The smallest pickup loops implemented have an inner (outer) diameter of 1 μm (2 μm). The superconducting loop is shunted by an on-chip parallel-plate capacitor with amorphous silicon dioxide as dielectric which was designed to have a capacitance of 80 pF. The superconducting loop and the capacitor form a resonator with a flux dependent resonance frequency from 5 to 12 GHz. The pickup loops are placed on opposite corners of the parallel-plate capacitor at a distance of about 450 μm so that one loop can be located in close proximity to the sample while the other is kept far away from it. External fields can be applied to the sample by local single-turn field coils situated around each pickup loop. The field coils are fully integrated into the chip layout and can also be used to bias the SQUID at its most sensitive point. Compared to using additional modulation coils,14 this approach has the advantage of reducing the total device inductance, which leads to a higher sensitivity.18 In a scanning microscope, the field coil at the rear end (away from the sample) can be used to bias the SQUID or operate it in flux feedback such that resulting stray fields will not act on the sample, apart from a weak screening current through the pickup loop. The effective diameter of each coil is 7.5 μm, resulting in a mutual inductance of about 0.34 Φ0/mA (for the smallest pickup loop). The SQUID resonator is connected by an on-chip Z0 = 50 Ω coplanar waveguide (CPW) transmission line to the bonding pads. The two field coils are connected by two smaller CPWs to the bottom edge bonding pads [Fig. 1(c)], ending in two parallel-stripline waveguides running alongside the edges of the capacitor towards the respective field coils. Based on estimations, it should thus be possible to apply high frequency signals of at least several GHz to SQUID and sample.
The current noise circulating around the loop of a tunnel junction dc SQUID has been measured as a function of applied flux. The flux noise generated by this current was coupled via a superconducting transformer to a second dc SQUID that was used to measure the noise in a null-balancing configuration. The voltage noise across the SQUID was also measured, using a cooled LC-resonant circuit, and the correlation between the voltage and current noises was determined. The measured values of the noises are in good agreement with values obtained from an analog simulator.
An all thin-film resistive SQUID with two Josephson tunnel junctions has been designed, fabricated and studied. As well as the two junctions, this device consists of a low ohmic (1.9*10 -6 Omega ) resistive part connected by superconducting leads to both junctions in a loop with very low ( approximately 10 -11 H) inductance. A direct current flowing through the resistive part fixes the voltage difference between the two Josephson junctions that are additionally fed by a bias current. The voltage difference is converted into a signal frequency that can be picked up from the SQUID with a conversion factor of ( phi o ) -1 =483.6 MHz mu V -1 , defined only by the electron charge and Planck's constant. An output signal level (peak-to-peak) of about 50 mu V has been obtained. The low frequency range (below 100 kHz) of the output signal frequency has been investigated. The possibilities of considerably extending this frequency range are also discussed.