A new method to measure picosecond or subpicosecond vibrational-dephasing dynamics with the use of incoherent or broadband light is presented theoretically and experimentally. It is based on a transient coherent Raman process with three beams. In our experimental scheme, two of them are incoherent light from a single source, and a delay time between the two is variable. A third beam has a higher frequency than the incoherent light by a vibrational energy in a molecule of interest, and is coherent in the delay-time range of the measurement. The delay-time dependence of coherent Stokes Raman scattering (CSRS) intensity offers the information about the coherence dynamics of the vibrational transition with a resolution time determined only by the correlation time of the incoherent light. For the theoretical calculation, a three-level model of the molecular system with homogeneous broadening is used, and delay-time dependences of the CSRS signal are calculated for off-resonance and resonance cases. Dephasing dynamics of the 2915-${\mathrm{cm}}^{\mathrm{\ensuremath{-}}1}$ mode in dimethylsulfoxide was observed experimentally by the new method with the use of nanosecond laser pulses, and the result agrees well with that obtained with picosecond pulses.
Time-delayed four-wave mixing using incoherent light has been proposed as a new method to measure the ultrafast population relaxation time T1. Assuming three input beams of incoherent light with much longer duration than T1, the theoretical calculation has shown that the decay curve by T1 appears in the signal profile and that the time resolution is determined by the correlation time of the light. The decay time to be observed is twice that of the transient four-wave mixing with short pulses. We have experimentally confirmed the prediction by observing picosecond population relaxations of organic dye solutions, using nanosecond pulses from a normal broadband dye laser. An advantage of the present method over the pump-probe method using incoherent light is also discussed.
In recent years, a series of nonlinear optical processes with incoherent light, such as time-delay four-wave mixing, optical Kerr effect and coherent Stokes Raman scattering, were developed and attracted much attention. It has been demonstrated that these processes can be used to measure the ultrafast dephasing times of excitations (shorter than 1 psec.) with nanosecond pulse lasers or even CW lasers. In this talk, after a short review of the works done by others previously theoretical and experimental investigations in this field in my laboratory are presented.
A new method of picosecond and femtosecond transient spectroscopy yielding information about ultrafast relaxation processes without requiring ultrashort light pulses is presented. It is based on the present theoretical analysis of the resonant degenerate four-wave-mixing process excited by two temporally incoherent light beams with wave vectors ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{1}$ and ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{2}$ which are originated from a single beam at frequency $\ensuremath{\omega}$ but have mutual time delay $\ensuremath{\tau}$. Under the assumption that the incoherent light field has Gaussian random complex amplitude and that the resonant material consists of the usual two-level atoms, the statistically averaged intensity of the output light field with ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{3}=2{\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{2}\ensuremath{-}{\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{1}$ at $\ensuremath{\omega}$ is calculated as a function of $\ensuremath{\tau}$. Even with the light having a much longer duration than both
T1 (the longitudinal relaxation time) and
T2 (the transverse relaxation time), the correlation trace, i.e., output intensity versus $\ensuremath{\tau}$, represents a decay profile determined mainly by
T2 for both homogeneously and inhomogeneously broadened transitions, as long as the light correlation time ${\ensuremath{\tau}}_{c}$ is much shorter than the relaxation times. The correlation trace does not always represent a single-exponential decay but is sometimes slightly deformed by the
T1 effect. However, it does not cause a significant error in the determination of
T2. Moreover, as $\frac{{T}_{2}}{{T}_{1}}\ensuremath{\rightarrow}0$, the trace becomes a single-exponential decay curve determined only by
T2. The feature of the results obtained by the present method is similar to that obtained by the conventional coherent transient spectroscopy with short pulses, such as the photon echo. The time resolution in the present method, however, is limited only by ${\ensuremath{\tau}}_{c}$ much shorter than the light duration. By regarding the incoherent light as a series of random ultrashort pulses, the present four-wave-mixing process is also interpreted as the ensemble of numerous transient four-wave-mixing processes caused by various combinations of these pulses.
New radiation-matter phenomena in four-wave mixing spectroscopies, given a theoretical basis in the preceding paper [Dugan and Albrecht, Phys. Rev. A 43, 3877 (1991)], are examined experimentally here. A new class of Rabi detuning oscillations is recorded in interferometric coherent Stokes Raman scattering (CSRS). Two identical nanosecond incoherent light fields are mutually delayed, while simultaneously mixing in a nonlinear medium with a narrow-band field of a different color. Spectral filtering of the CSRS signal is essential. From such signals the frequencies and the dephasing rate constants can be a measure of the Raman-active vibrations in both the electronic ground state and the electronic excited state of the scattering chromophore. In principle, analogous probing of vibronic transitions is possible. Detuning oscillations for multimode systems are presented. It is shown how they are transformed into quantum beats, exactly those seen with femtosecond CSRS, when the narrow-band field is made broad and/or the detection is ``white.'' Finally, an example of the sub-Raman linewidth spectral feature, predicted in the preceding paper, is presented. It determines a Raman frequency, but does not carry its linewidth.
Since 1984, many theoretical and experimental studies have shown that the time resolution in certain four-wave-mixing experiments (e.g. degenerate four-wave-mixing, coherent Stokes Raman scattering) is determined by the coherence time of the pulses rather than their widths [1]. In this paper it is shown that this concept is also valid for a new experimental technique: the Raman Fringe Decay (RFD) [2]. Furthermore it is shown that the interpretation of the results becomes more complex when the detection bandwidth is small compared to the inverse dephasing time due to coherence effects.