Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Experimental and Theoretical Physics

Source of a regular flux of photons

Yu. M. Golubev, D. F. Parsons

Published Dec 1, 1991• 0 citations
OpenAlex

Related papers

Radiometric calibration of a multiphoton microscope capable of measuring absolute photon flux of single photon sources

Yangting Fu, Xiangliang Liu, Yingwei He +3 more

Precise photon flux measurement of single photon sources (SPSs) is essential to the successful application of SPSs. In this work, a novel method, to our knowledge, was proposed for direct measurement of the absolute photon flux of single photon sources with a femtosecond laser multiphoton microscope. A secondary 2-mm-diameter aperture was installed under the microscope objective to define the numerical aperture (NA) of the microscope. The defined NA was precisely measured to be 0.447. An LED-based miniaturized integrating sphere light source (LED-ISLS) was used as a standard radiance source to calibrate the photon flux responsivity of the multiphoton microscope, with the defined NA. The combined standard uncertainty of the measured photon flux responsivity was 1.97%. Absolute photon flux from a quantum-dot based emitter was measured by the multiphoton microscope. The uncertainty of the photon flux was evaluated to be 2.1%. This work offers a new, to our knowledge, radiometric method for fast calibration of photon flux responsivity of microscopes, and absolute photon flux calibration of single photon sources.

Optics Express•Jun 3, 2022•0 citations

Intense source of monochromatic photons

L. J. Orphanos, J. S. McCarthy, B. Norum +1 more

•Jan 1, 1983•0 citations

Experimental demonstration of a predictable single photon source with variable photon flux

Aigar Vaigu, Geiland Porrovecchio, Xiao‐Liu Chu +7 more

Abstract We present a predictable single-photon source (SPS) based on a silicon vacancy centre in nanodiamond which is optically excited by a pulsed laser. At an excitation rate of 70 M H z the source delivers a photon flux large enough to be measured by a low optical flux detector (LOFD). The directly measured photon flux constitutes an absolute reference. By changing the repetition rate of the pulsed laser, we are able to change the photon flux of our SPS in a controllable way which in turn can act as a reference. The advantage of our method is that it does not require precise knowledge of the source efficiency, but the source is calibrated by the LOFD and can be used for detector responsivity characterizations at the few-photon level.

Metrologia•Mar 21, 2017•19 citations

Bright Source of Photon Pairs

Science•Jul 6, 2006•0 citations

A continuous observation of photon emission

V. P. Belavkin, P. Staszewski

Reports on Mathematical Physics•Apr 1, 1991•25 citations

Experimental realization of an absolute single-photon source based on a single nitrogen vacancy center in a nanodiamond

Beatrice Rodiek, Marco López, Helmuth Hofer +8 more

We report on the experimental realization of an absolute single-photon source based on a single nitrogen vacancy (NV) center in a nanodiamond at room temperature and on the calculation of its absolute spectral photon flux from experimental data. The single-photon source was calibrated with respect to its photon flux and its spectral photon rate density. The photon flux was measured with a low-noise silicon photodiode traceable to the primary standard for optical flux, taking into account the absolute spectral power distribution using a calibrated spectroradiometer. The optical radiant flux is adjustable from 55 fW, which is almost the lowest detection limit for the silicon photodiode, and 75 fW, which is the saturation power of the NV center. These fluxes correspond to total photon flux rates between 190,000 photons per second and 260,000 photons per second, respectively. The single-photon emission purity is indicated by a g((2))(0) value, which is between 0.10 and 0.23, depending on the excitation power. To our knowledge, this is the first single-photon source absolutely calibrated with respect to its absolute optical radiant flux and spectral power distribution, traceable to the corresponding national standards via an unbroken traceability chain. The prospects for its application, e.g., for the detection efficiency calibration of single-photon detectors as well as for use as a standard photon source in the low photon flux regime, are promising. (C) 2017 Optical Society of America

Optica•Jan 4, 2017•79 citations
Precise photon flux measurement of single photon sources (SPSs) is essential to the successful application of SPSs. In this work, a novel method, to our knowledge, was proposed for direct measurement of the absolute photon flux of single photon sources with a femtosecond laser multiphoton microscope. A secondary 2-mm-diameter aperture was installed under the microscope objective to define the numerical aperture (NA) of the microscope. The defined NA was precisely measured to be 0.447. An LED-based miniaturized integrating sphere light source (LED-ISLS) was used as a standard radiance source to calibrate the photon flux responsivity of the multiphoton microscope, with the defined NA. The combined standard uncertainty of the measured photon flux responsivity was 1.97%. Absolute photon flux from a quantum-dot based emitter was measured by the multiphoton microscope. The uncertainty of the photon flux was evaluated to be 2.1%. This work offers a new, to our knowledge, radiometric method for fast calibration of photon flux responsivity of microscopes, and absolute photon flux calibration of single photon sources.
Abstract We present a predictable single-photon source (SPS) based on a silicon vacancy centre in nanodiamond which is optically excited by a pulsed laser. At an excitation rate of 70 M H z the source delivers a photon flux large enough to be measured by a low optical flux detector (LOFD). The directly measured photon flux constitutes an absolute reference. By changing the repetition rate of the pulsed laser, we are able to change the photon flux of our SPS in a controllable way which in turn can act as a reference. The advantage of our method is that it does not require precise knowledge of the source efficiency, but the source is calibrated by the LOFD and can be used for detector responsivity characterizations at the few-photon level.
We report on the experimental realization of an absolute single-photon source based on a single nitrogen vacancy (NV) center in a nanodiamond at room temperature and on the calculation of its absolute spectral photon flux from experimental data. The single-photon source was calibrated with respect to its photon flux and its spectral photon rate density. The photon flux was measured with a low-noise silicon photodiode traceable to the primary standard for optical flux, taking into account the absolute spectral power distribution using a calibrated spectroradiometer. The optical radiant flux is adjustable from 55 fW, which is almost the lowest detection limit for the silicon photodiode, and 75 fW, which is the saturation power of the NV center. These fluxes correspond to total photon flux rates between 190,000 photons per second and 260,000 photons per second, respectively. The single-photon emission purity is indicated by a g((2))(0) value, which is between 0.10 and 0.23, depending on the excitation power. To our knowledge, this is the first single-photon source absolutely calibrated with respect to its absolute optical radiant flux and spectral power distribution, traceable to the corresponding national standards via an unbroken traceability chain. The prospects for its application, e.g., for the detection efficiency calibration of single-photon detectors as well as for use as a standard photon source in the low photon flux regime, are promising. (C) 2017 Optical Society of America