Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Institute of Physics eBooks

Putting it all together: quantum process tomography and pump–probe spectroscopies

Joel Y. Yuen-Zhou, Jacob J. Krich, Ivan Kassal, Allan S. Johnson, Alán Aspuru‐Guzik

Published Sep 1, 2014• 0 citations
Publisher
DOI
10.1088/978-0-750-31062-8ch5

Related papers

Quantum state and process tomography of energy transfer systems via ultrafast spectroscopy

Joel Y. Yuen-Zhou, Jacob J. Krich, Masoud Mohseni +1 more

The description of excited state dynamics in energy transfer systems constitutes a theoretical and experimental challenge in modern chemical physics. A spectroscopic protocol that systematically characterizes both coherent and dissipative processes of the probed chromophores is desired. Here, we show that a set of two-color photon-echo experiments performs quantum state tomography (QST) of the one-exciton manifold of a dimer by reconstructing its density matrix in real time. This possibility in turn allows for a complete description of excited state dynamics via quantum process tomography (QPT). Simulations of a noisy QPT experiment for an inhomogeneously broadened ensemble of model excitonic dimers show that the protocol distills rich information about dissipative excitonic dynamics, which appears nontrivially hidden in the signal monitored in single realizations of four-wave mixing experiments.

arXiv:1006.4866•Proceedings of the National Academy of Sciences•Oct 12, 2011•88 citations

Quantum Process Tomography

Norman Y. Yao, Chris R. Laumann, Alexey Vyacheslavovich Gorshkov +2 more

•Jan 1, 2016•0 citations

Correlation-assisted process tomography

Matteo Caiaffa, Marco Piani

Standard quantum process tomography on a $d$-dimensional input is performed by preparing several states of an input probe that then evolve under the action of the quantum channel corresponding to the progress. The final states of the probe are reconstructed by means of state tomography. An alternative is offered by ancilla-assisted process tomography: a single probe-ancilla state is used, and the correlations existing between probe and ancilla are exploited to fully reconstruct the information on the channel. In order for ancilla-assisted process tomography to be possible, the probe-ancilla input state does not need to be entangled, but still needs to have maximal operator Schmidt rank. Here we establish and analyze a framework for process tomography that interpolates between these two methods, aiming at exploiting any correlations that may exist between probe and ancilla to allow process tomography with as few input preparations as possible, when the probe-ancilla state may be operator-Schmidt-rank deficient. The main object of our investigation is the minimal number of initial local operations on the input probe for a given starting probe-ancilla state that are needed to allow process tomography. We prove that such a number scales inversely proportional to the operator Schmidt rank of the input probe-ancilla state for arbitrary local input processing. We also provide results for the case where this initial local processing is restricted to be a unitary rotation, in particular showing that the mentioned scaling is satisfied for pure input entangled states, and that in the case of mixed states there might be extreme cases where the fixed input probe-ancilla state provides information on a $\approx d^2/2$-dimensional subspace of the operator space and a single additional input unitary rotation allows process tomography.

arXiv:1808.10835•Aug 31, 2018•1 citation

From Blind Quantum Source Separation to Blind Quantum Process Tomography

Yannick Deville, Alain Deville

Lecture notes in computer science•Aug 15, 2015•24 citations

Nonlinear ground-state pump-probe spectroscopy in ultracold rubidium: Raman-coupled dressed state spectroscopy

Arthur K. Mills

We present our experimental investigations of nonlinear ground-state pump-probe spectroscopy in ultracold rubidium 85 produced in a magneto-optical trap (MOT). Nonlinear ground-state pump-probe spectroscopy is a two-photon analog of traditional two-level pump-probe spectroscopy. When a two-level atom is driven with an intense, single frequency near-resonant laser field the absorption spectrum of a weak probe field exhibits absorption and gain features not seen without the pump field. These saturated absorption line shapes, obtained under different pump field conditions, are known as the Mollow spectra. Nonlinear ground-state pump-probe spectroscopy is a three-level process, in which an intense two-photon pump field drives transitions between two components of the ground state coupled through an intermediate excited state. When the frequencies of the pump fields are tuned far from the intermediate state resonance, spontaneous emission is significantly reduced and narrow spectral lines are possible. The absorption/gain spectrum of a weak probe field, tuned in the vicinity of the intermediate state virtual level, resembles the Mollow spectrum except that new interference processes arise due to competition between two-photon pathways involving the probe field and each of the two pump fields. This interference significantly affects the probe absorption spectrum, and new features appear that are not present in the two-level case. We describe our measurements of this process, including the MOT that produces the ultracold collection of atoms, and the system of injection-locked extended cavity diode lasers that produce the phase-coherent laser fields used in our measurements.

•Jan 1, 2007•1 citation

Quantum Process Tomography and Regression

Péter Wittek

Elsevier eBooks•Jan 1, 2014•1 citation
The description of excited state dynamics in energy transfer systems constitutes a theoretical and experimental challenge in modern chemical physics. A spectroscopic protocol that systematically characterizes both coherent and dissipative processes of the probed chromophores is desired. Here, we show that a set of two-color photon-echo experiments performs quantum state tomography (QST) of the one-exciton manifold of a dimer by reconstructing its density matrix in real time. This possibility in turn allows for a complete description of excited state dynamics via quantum process tomography (QPT). Simulations of a noisy QPT experiment for an inhomogeneously broadened ensemble of model excitonic dimers show that the protocol distills rich information about dissipative excitonic dynamics, which appears nontrivially hidden in the signal monitored in single realizations of four-wave mixing experiments.
Standard quantum process tomography on a ddd-dimensional input is performed by preparing several states of an input probe that then evolve under the action of the quantum channel corresponding to the progress. The final states of the probe are reconstructed by means of state tomography. An alternative is offered by ancilla-assisted process tomography: a single probe-ancilla state is used, and the correlations existing between probe and ancilla are exploited to fully reconstruct the information on the channel. In order for ancilla-assisted process tomography to be possible, the probe-ancilla input state does not need to be entangled, but still needs to have maximal operator Schmidt rank. Here we establish and analyze a framework for process tomography that interpolates between these two methods, aiming at exploiting any correlations that may exist between probe and ancilla to allow process tomography with as few input preparations as possible, when the probe-ancilla state may be operator-Schmidt-rank deficient. The main object of our investigation is the minimal number of initial local operations on the input probe for a given starting probe-ancilla state that are needed to allow process tomography. We prove that such a number scales inversely proportional to the operator Schmidt rank of the input probe-ancilla state for arbitrary local input processing. We also provide results for the case where this initial local processing is restricted to be a unitary rotation, in particular showing that the mentioned scaling is satisfied for pure input entangled states, and that in the case of mixed states there might be extreme cases where the fixed input probe-ancilla state provides information on a ≈d2/2\approx d^2/2≈d2/2-dimensional subspace of the operator space and a single additional input unitary rotation allows process tomography.
We present our experimental investigations of nonlinear ground-state pump-probe spectroscopy in ultracold rubidium 85 produced in a magneto-optical trap (MOT). Nonlinear ground-state pump-probe spectroscopy is a two-photon analog of traditional two-level pump-probe spectroscopy. When a two-level atom is driven with an intense, single frequency near-resonant laser field the absorption spectrum of a weak probe field exhibits absorption and gain features not seen without the pump field. These saturated absorption line shapes, obtained under different pump field conditions, are known as the Mollow spectra. Nonlinear ground-state pump-probe spectroscopy is a three-level process, in which an intense two-photon pump field drives transitions between two components of the ground state coupled through an intermediate excited state. When the frequencies of the pump fields are tuned far from the intermediate state resonance, spontaneous emission is significantly reduced and narrow spectral lines are possible. The absorption/gain spectrum of a weak probe field, tuned in the vicinity of the intermediate state virtual level, resembles the Mollow spectrum except that new interference processes arise due to competition between two-photon pathways involving the probe field and each of the two pump fields. This interference significantly affects the probe absorption spectrum, and new features appear that are not present in the two-level case. We describe our measurements of this process, including the MOT that produces the ultracold collection of atoms, and the system of injection-locked extended cavity diode lasers that produce the phase-coherent laser fields used in our measurements.