Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Phase difference enhancement with classical intensity interferometry

Tomohiro Shirai

Published Jun 16, 2016• 3 citations
Publisher
DOI
10.1016/j.optcom.2016.06.015

Related papers

Phase Difference Amplification with Intensity Interferometry and Its Implication

Tomohiro Shirai

The Japan Society of Applied Physics•Jul 22, 2016•0 citations

Modern Aspects of Intensity Interferometry With Classical Light

Tomohiro Shirai

Progress in optics•Jan 1, 2017•26 citations

Robust phase sensitivity in Mach-Zehnder interferometer using photon added and subtracted squeezed coherent state

Shivani Singh, Priya Malpani, Anirban Pathak

For the precision-based measurements, Mach-Zehnder interferometry is a widely used technique. There are various ways to enhance the precision of Mach-Zehnder interferometer (MZI), e.g., having a non-classical input state is one of the ways to enhance the precision of the phase estimation performed by MZI. The phase estimation performed by MZI is investigated here by considering that the input states of MZI are different combinations of photon added and subtracted squeezed coherent states (PASCS and PSSCS). Using quantum Fisher information, it is shown that the use of PASCS in both the input modes of MZI, provides the most precise estimate of the unknown phase. This system is also analyzed in two different measurement scenarios -- single intensity detection (SID) and intensity difference detection (IDD). Systematic analysis has established that the intensity measurement might not be an optimal measurement scheme for phase estimation in MZI as phase and intensity correspond to non-commuting observables. The impact of the photon loss on the MZI-based phase estimation setup is also studied and it is found that PASCS is robust against photon loss, when the loss in MZI is low.

quant-pharXiv:2607.02984•Jul 6, 2026•0 citations

Enhanced phase sensitivity of the Mach-Zehnder-type phase-shifting interferometry with single-intensity and difference-intensity detection

Huanrong He, Yu Zhang

Phase-shifting interferometry (PSI) promises excellent performance for quantitative phase measurement. However, the PSI is commonly realized by utilizing the Mach-Zehnder interferometer (MZI) fed with classical resources, and hence its phase sensitivity is hindered by the photon shot noise. In this paper, we propose to introduce specific phase-shifting algorithms into the well-established quantum-enhanced MZI, seeded by coherent and squeezed vacuum states and followed by single-mode intensity detection and difference intensity detection, to achieve quantitative phase measurement with sensitivity beyond that achieved by the corresponding Mach-Zehnder-type PSI with classical input. We show that when the average photon number of the coherent state is dominant, the optimal phase sensitivity of the Mach-Zehnder-type PSI with coherent plus squeezed vacuum input is better than the phase sensitivity of the Mach-Zehnder-type PSI with single coherent input under the same phase-sensing intensity condition in both of detection setups. We also show that for the typical MZI seeded with a high-power coherent state and a finitely squeezed vacuum state, the combination of intensity detection and phase-shifting algorithm can still improve the sensitivity of quantitative phase measurement. Furthermore, we derive the phase sensitivity of the fixed MZI as well as the quantum Cramér-Rao bound for two detection schemes. Finally, we explore the impacts of photon losses on the phase sensitivity enhancements of the Mach-Zehnder-type PSI and the fixed MZI in the high-intensity regime for each detection setup. The robustness to losses is compared between the Mach-Zehnder-type PSI and the fixed MZI. Our results may be helpful to promote the exploration of quantum-enhanced quantitative phase sensing.

Optics Express•Jul 17, 2026•0 citations

Experiments on intensity interferometry

Andreas Zmija, Peter Deiml, A. Zink +7 more

Verhandlungen der Deutschen Physikalischen Gesellschaft•Jan 1, 2018•0 citations

Improved Spatial Resolution Achieved by Chromatic Intensity Interferometry

Lu-Chuan Liu, Luo-Yuan Qu, Cheng Wu +8 more

Interferometers are widely used in imaging technologies to achieve enhanced spatial resolution, but require that the incoming photons be indistinguishable. In previous work, we built and analyzed color erasure detectors, which expand the scope of intensity interferometry to accommodate sources of different colors. Here we demonstrate experimentally how color erasure detectors can achieve improved spatial resolution in an imaging task, well beyond the diffraction limit. Utilizing two 10.9-mm-aperture telescopes and a 0.8 m baseline, we measure the distance between a 1063.6 and a 1064.4 nm source separated by 4.2 mm at a distance of 1.43 km, which surpasses the diffraction limit of a single telescope by about 40 times. Moreover, chromatic intensity interferometry allows us to recover the phase of the Fourier transform of the imaged objects-a quantity that is, in the presence of modest noise, inaccessible to conventional intensity interferometry.

arXiv:2102.02060•Physical Review Letters•Aug 31, 2021•10 citations
For the precision-based measurements, Mach-Zehnder interferometry is a widely used technique. There are various ways to enhance the precision of Mach-Zehnder interferometer (MZI), e.g., having a non-classical input state is one of the ways to enhance the precision of the phase estimation performed by MZI. The phase estimation performed by MZI is investigated here by considering that the input states of MZI are different combinations of photon added and subtracted squeezed coherent states (PASCS and PSSCS). Using quantum Fisher information, it is shown that the use of PASCS in both the input modes of MZI, provides the most precise estimate of the unknown phase. This system is also analyzed in two different measurement scenarios -- single intensity detection (SID) and intensity difference detection (IDD). Systematic analysis has established that the intensity measurement might not be an optimal measurement scheme for phase estimation in MZI as phase and intensity correspond to non-commuting observables. The impact of the photon loss on the MZI-based phase estimation setup is also studied and it is found that PASCS is robust against photon loss, when the loss in MZI is low.
Phase-shifting interferometry (PSI) promises excellent performance for quantitative phase measurement. However, the PSI is commonly realized by utilizing the Mach-Zehnder interferometer (MZI) fed with classical resources, and hence its phase sensitivity is hindered by the photon shot noise. In this paper, we propose to introduce specific phase-shifting algorithms into the well-established quantum-enhanced MZI, seeded by coherent and squeezed vacuum states and followed by single-mode intensity detection and difference intensity detection, to achieve quantitative phase measurement with sensitivity beyond that achieved by the corresponding Mach-Zehnder-type PSI with classical input. We show that when the average photon number of the coherent state is dominant, the optimal phase sensitivity of the Mach-Zehnder-type PSI with coherent plus squeezed vacuum input is better than the phase sensitivity of the Mach-Zehnder-type PSI with single coherent input under the same phase-sensing intensity condition in both of detection setups. We also show that for the typical MZI seeded with a high-power coherent state and a finitely squeezed vacuum state, the combination of intensity detection and phase-shifting algorithm can still improve the sensitivity of quantitative phase measurement. Furthermore, we derive the phase sensitivity of the fixed MZI as well as the quantum Cramér-Rao bound for two detection schemes. Finally, we explore the impacts of photon losses on the phase sensitivity enhancements of the Mach-Zehnder-type PSI and the fixed MZI in the high-intensity regime for each detection setup. The robustness to losses is compared between the Mach-Zehnder-type PSI and the fixed MZI. Our results may be helpful to promote the exploration of quantum-enhanced quantitative phase sensing.
Interferometers are widely used in imaging technologies to achieve enhanced spatial resolution, but require that the incoming photons be indistinguishable. In previous work, we built and analyzed color erasure detectors, which expand the scope of intensity interferometry to accommodate sources of different colors. Here we demonstrate experimentally how color erasure detectors can achieve improved spatial resolution in an imaging task, well beyond the diffraction limit. Utilizing two 10.9-mm-aperture telescopes and a 0.8 m baseline, we measure the distance between a 1063.6 and a 1064.4 nm source separated by 4.2 mm at a distance of 1.43 km, which surpasses the diffraction limit of a single telescope by about 40 times. Moreover, chromatic intensity interferometry allows us to recover the phase of the Fourier transform of the imaged objects-a quantity that is, in the presence of modest noise, inaccessible to conventional intensity interferometry.