Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Review of Scientific Instruments

Optomechanical design and construction of a vacuum-compatible optical parametric oscillator for generation of squeezed light

Andrew R. Wade, Georgia L. Mansell, T. McRae, S. Chua, M. J. Yap, Robert L. Ward, Bram J. J. Slagmolen, D. A. Shaddock, David E. McClelland

Published Jun 1, 2016• 5 citations
Publisher

Abstract

With the recent detection of gravitational waves, non-classical light sources are likely to become an essential element of future detectors engaged in gravitational wave astronomy and cosmology. Operating a squeezed light source under high vacuum has the advantages of reducing optical losses and phase noise compared to techniques where the squeezed light is introduced from outside the vacuum. This will ultimately provide enhanced sensitivity for modern interferometric gravitational wave detectors that will soon become limited by quantum noise across much of the detection bandwidth. Here we describe the optomechanical design choices and construction techniques of a near monolithic glass optical parametric oscillator that has been operated under a vacuum of 10(-6) mbar. The optical parametric oscillator described here has been shown to produce 8.6 dB of quadrature squeezed light in the audio frequency band down to 10 Hz. This performance has been maintained for periods of around an hour and the system has been under vacuum continuously for several months without a degradation of this performance.

DOI
10.1063/1.4953326

Related papers

Squeezed light sources for current and future interferometric gravitational-wave detectors

Georgia L. Mansell

The era of gravitational-wave astronomy has begun, with the detection of 5 confirmed binary black holes and a binary neutron star coalescence by the Advanced Laser Interferometer Gravitational- wave Observatory (aLIGO), and later with the advanced Virgo detector. These detections have already revealed a wealth of discoveries across the fields of nuclear physics, general relativity and astrophysics. The work presented in this thesis is part of the ongoing effort to improve the sensitivity of ground-based interferometric gravitational-wave detectors. The sensitivity of aLIGO, and other interferometric detectors, is broadly limited by quantum noise. Improving on the quantum noise will increase the astrophysical range of the detectors, and improve the source parameter estimation. One way to reduce quantum noise is to inject audio- band squeezed vacuum states into the detection port. This technique has been demonstrated on the initial LIGO and GEO600 detectors. A squeezed light source for aLIGO must meet stringent requirements in terms of optical loss, phase noise, and scattered light. The squeezer must produce high levels of audio-band squeezing and operate under vacuum, to take advantage of the excellent existing isolation systems and to minimise optical loss. At design sensitivity, squeezed states whose quantum noise depends on frequency will be required. We have demonstrated an ultra-stable glass-based squeezed light source, the first experiment of this kind to operate under vacuum. The squeezer cavity is constructed quasi-monolithically, with optics and nonlinear crystal oven optically contacted to a breadboard base. The cavity is designed to have extremely low length noise, and to produce high levels of audio-band squeezing. We have measured 8.6 ± 0.9 dB of squeezing and infer the generation of 14.2 ± 1.0 dB after accounting for all known losses. The squeezer has demonstrated record phase noise performance of 1.3 mradRMS, dominated by sources other than cavity length noise. This exceeds the phase-noise requirement for a squeezer for aLIGO. A copy of this squeezer is currently being installed in a squeezing- ellipse rotation experiment to demonstrate frequency-dependent squeezing for aLIGO. Lessons learnt during the construction and operation of the in-vacuum squeezer have helped inform the design of a frequency-independent squeezed light source currently being installed at the LIGO sites. Future gravitational-wave detectors will continue to use interferometric techniques, and will be limited by quantum noise for the foreseeable future. To improve on thermal noise limits and interferometer power handling, future detectors look to cryogenic silicon as a test mass material. To take advantage of the desirable properties of silicon, including low scatter and absorption, a longer operating wavelength is required. The proposed LIGO Voyager upgrade has an operating wavelength in the 2 μ m region, with the specific wavelength to be determined. LIGO Voyager will require a squeezed light source in the 2 μ m region to reach its design sensitivity. We present the design, characterisation, and results of the first squeezed light source in the 2 μ m region. Laser and detector technologies at 2 μ m are less developed than their 1064 nm counterparts, causing significant technical challenges. We have measured 4.0 ± 0.2 dB of squeez- ing at 1984 nm, limited by loss due to detector quantum efficiency. Accounting for known losses in the system, we infer the generation of 10 dB of squeezing. This is an important demonstra- tion of quantum noise reduction for future detectors, and a pathfinder technology for the design choices of LIGO Voyager. So far we have found no reason why a 2 μ m interferometer should not be feasible.

•Jan 1, 2018•0 citations

Ultra-low phase noise squeezed vacuum source for gravitational wave detectors

Eric Glenn Oelker, Georgia L. Mansell, M. Tse +7 more

Squeezed states of light are a valuable resource for reducing quantum noise in precision measurements. Injection of squeezed vacuum states has emerged as an important technique for reducing quantum shot noise, which is a fundamental limitation to the sensitivity of interferometric gravitational wave detectors. Realizing the most benefit from squeezed-state injection requires lowering optical losses and also minimizing squeezed quadrature fluctuations—or phase noise—to ensure that the large noise in the anti-squeezed quadrature does not contaminate the measurement quadrature. Here, we present an audio band squeezed vacuum source with 1.3+0.7−0.5 mrad of phase noise. This is a nearly tenfold improvement over previously reported measurements, improving prospects for squeezing enhancements in current and future gravitational wave detectors.

Optica•Jun 23, 2016•62 citations

Generation and detection of low-frequency squeezing for gravitational-wave detection

Michael Stefszky

Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.

•Jan 1, 2012•1 citation

Squeezed light for gravitational wave astronomy

H. Vahlbruch

During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.

•Jan 1, 2008•12 citations

High-efficiency squeezed light generation for gravitational wave detectors

Moritz Mehmet, H. Vahlbruch

The engineering of strongly squeezed vacuum states of light is a key technology for the reduction of quantum noise in gravitational wave detectors. We report on the observation of up to 12.0 dB squeezed vacuum states of light at the wavelength of 1064 nm in the frequency band from 10 Hz to 100 kHz. This is the strongest squeezing reported to date within this detection band. The squeezed states were generated in a half-monolithic, standing-wave cavity optical parametric amplifier, which was resonant for the fundamental and harmonic light fields. We chose appropriate reflectivities to obtain a significant reduction of the required pump power, which was 8.6 mW only. Our analysis revealed that the residual measurement phase noise was smaller than 3.5 mrad rms and that the squeezed light source provided up to 14 dB of squeezing for a downstream application. The experiment was electronically stabilized in all relevant degrees of freedom, demonstrating the applicability of the linear, doubly resonant cavity topology for current and future gravitational wave detectors.

Classical and Quantum Gravity•Nov 27, 2018•45 citations

Audio-Band Frequency-Dependent Squeezing for Gravitational-Wave Detectors

Eric Glenn Oelker, Tomoki Isogai, John Miller +4 more

Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. However, optomechanical interactions dictate that the vacuum's squeezed quadrature must rotate by 90° around 50 Hz. Here we use a 2-m-long, high-finesse optical resonator to produce frequency-dependent rotation around 1.2 kHz. This demonstration of audio-band frequency-dependent squeezing uses technology and methods that are scalable to the required rotation frequency and validates previously developed theoretical models, heralding application of the technique in future gravitational-wave detectors.

arXiv:1508.04700•Physical Review Letters•Jan 29, 2016•94 citations
With the recent detection of gravitational waves, non-classical light sources are likely to become an essential element of future detectors engaged in gravitational wave astronomy and cosmology. Operating a squeezed light source under high vacuum has the advantages of reducing optical losses and phase noise compared to techniques where the squeezed light is introduced from outside the vacuum. This will ultimately provide enhanced sensitivity for modern interferometric gravitational wave detectors that will soon become limited by quantum noise across much of the detection bandwidth. Here we describe the optomechanical design choices and construction techniques of a near monolithic glass optical parametric oscillator that has been operated under a vacuum of 10(-6) mbar. The optical parametric oscillator described here has been shown to produce 8.6 dB of quadrature squeezed light in the audio frequency band down to 10 Hz. This performance has been maintained for periods of around an hour and the system has been under vacuum continuously for several months without a degradation of this performance.
The era of gravitational-wave astronomy has begun, with the detection of 5 confirmed binary black holes and a binary neutron star coalescence by the Advanced Laser Interferometer Gravitational- wave Observatory (aLIGO), and later with the advanced Virgo detector. These detections have already revealed a wealth of discoveries across the fields of nuclear physics, general relativity and astrophysics. The work presented in this thesis is part of the ongoing effort to improve the sensitivity of ground-based interferometric gravitational-wave detectors. The sensitivity of aLIGO, and other interferometric detectors, is broadly limited by quantum noise. Improving on the quantum noise will increase the astrophysical range of the detectors, and improve the source parameter estimation. One way to reduce quantum noise is to inject audio- band squeezed vacuum states into the detection port. This technique has been demonstrated on the initial LIGO and GEO600 detectors. A squeezed light source for aLIGO must meet stringent requirements in terms of optical loss, phase noise, and scattered light. The squeezer must produce high levels of audio-band squeezing and operate under vacuum, to take advantage of the excellent existing isolation systems and to minimise optical loss. At design sensitivity, squeezed states whose quantum noise depends on frequency will be required. We have demonstrated an ultra-stable glass-based squeezed light source, the first experiment of this kind to operate under vacuum. The squeezer cavity is constructed quasi-monolithically, with optics and nonlinear crystal oven optically contacted to a breadboard base. The cavity is designed to have extremely low length noise, and to produce high levels of audio-band squeezing. We have measured 8.6 ± 0.9 dB of squeezing and infer the generation of 14.2 ± 1.0 dB after accounting for all known losses. The squeezer has demonstrated record phase noise performance of 1.3 mradRMS, dominated by sources other than cavity length noise. This exceeds the phase-noise requirement for a squeezer for aLIGO. A copy of this squeezer is currently being installed in a squeezing- ellipse rotation experiment to demonstrate frequency-dependent squeezing for aLIGO. Lessons learnt during the construction and operation of the in-vacuum squeezer have helped inform the design of a frequency-independent squeezed light source currently being installed at the LIGO sites. Future gravitational-wave detectors will continue to use interferometric techniques, and will be limited by quantum noise for the foreseeable future. To improve on thermal noise limits and interferometer power handling, future detectors look to cryogenic silicon as a test mass material. To take advantage of the desirable properties of silicon, including low scatter and absorption, a longer operating wavelength is required. The proposed LIGO Voyager upgrade has an operating wavelength in the 2 μ m region, with the specific wavelength to be determined. LIGO Voyager will require a squeezed light source in the 2 μ m region to reach its design sensitivity. We present the design, characterisation, and results of the first squeezed light source in the 2 μ m region. Laser and detector technologies at 2 μ m are less developed than their 1064 nm counterparts, causing significant technical challenges. We have measured 4.0 ± 0.2 dB of squeez- ing at 1984 nm, limited by loss due to detector quantum efficiency. Accounting for known losses in the system, we infer the generation of 10 dB of squeezing. This is an important demonstra- tion of quantum noise reduction for future detectors, and a pathfinder technology for the design choices of LIGO Voyager. So far we have found no reason why a 2 μ m interferometer should not be feasible.
Squeezed states of light are a valuable resource for reducing quantum noise in precision measurements. Injection of squeezed vacuum states has emerged as an important technique for reducing quantum shot noise, which is a fundamental limitation to the sensitivity of interferometric gravitational wave detectors. Realizing the most benefit from squeezed-state injection requires lowering optical losses and also minimizing squeezed quadrature fluctuations—or phase noise—to ensure that the large noise in the anti-squeezed quadrature does not contaminate the measurement quadrature. Here, we present an audio band squeezed vacuum source with 1.3+0.7−0.5 mrad of phase noise. This is a nearly tenfold improvement over previously reported measurements, improving prospects for squeezing enhancements in current and future gravitational wave detectors.
Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.
During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.
The engineering of strongly squeezed vacuum states of light is a key technology for the reduction of quantum noise in gravitational wave detectors. We report on the observation of up to 12.0 dB squeezed vacuum states of light at the wavelength of 1064 nm in the frequency band from 10 Hz to 100 kHz. This is the strongest squeezing reported to date within this detection band. The squeezed states were generated in a half-monolithic, standing-wave cavity optical parametric amplifier, which was resonant for the fundamental and harmonic light fields. We chose appropriate reflectivities to obtain a significant reduction of the required pump power, which was 8.6 mW only. Our analysis revealed that the residual measurement phase noise was smaller than 3.5 mrad rms and that the squeezed light source provided up to 14 dB of squeezing for a downstream application. The experiment was electronically stabilized in all relevant degrees of freedom, demonstrating the applicability of the linear, doubly resonant cavity topology for current and future gravitational wave detectors.
Quantum vacuum fluctuations impose strict limits on precision displacement measurements, those of interferometric gravitational-wave detectors among them. Introducing squeezed states into an interferometer's readout port can improve the sensitivity of the instrument, leading to richer astrophysical observations. However, optomechanical interactions dictate that the vacuum's squeezed quadrature must rotate by 90° around 50 Hz. Here we use a 2-m-long, high-finesse optical resonator to produce frequency-dependent rotation around 1.2 kHz. This demonstration of audio-band frequency-dependent squeezing uses technology and methods that are scalable to the required rotation frequency and validates previously developed theoretical models, heralding application of the technique in future gravitational-wave detectors.