The principle,the method and the experimental system of mid-infrared radiance calibration based on parametric amplification technique were introduced.The equation between different polarization source and its photons per mode was deduced.A high power CW laser stabilized at 532 nm was used to pump a LiNbO_3 nonlinear crystal,producing two correlated-photons whose wavelengths were 632.8 nm and 3.34μm,respectively.The under-calibrated blackbody at 3.34μm was injected along the direction of the infrared down-converted photons.With the high relativity of the VIS-IR photon pairs,through the measurement of the visible down-converted photons at 632.8 nm,the radiance of the blackbody source at 3.34μm can be calibrated and 1.53%relative standard uncertainty was reported.
The principle,the method and the experimental system of mid-infrared radiance calibration based on parametric amplification technique were introduced.The equation between different polarization source and its photons per mode was deduced.A high power CW laser stabilized at 532 nm was used to pump a LiNbO_3 nonlinear crystal,producing two correlated-photons whose wavelengths were 632.8 nm and 3.34μm,respectively.The under-calibrated blackbody at 3.34μm was injected along the direction of the infrared down-converted photons.With the high relativity of the VIS-IR photon pairs,through the measurement of the visible down-converted photons at 632.8 nm,the radiance of the blackbody source at 3.34μm can be calibrated and 1.53%relative standard uncertainty was reported.
Visible-infrared photon pair sources working in broadband mid-infrared region are useful for applications such as heralded mid-infrared single photon sources. Here, we demonstrate experimentally a wavelength variable visible-infrared photon pair source in the mid-infrared region over a wide spectral range of 2 to 5 μm. By changing the angle of the nonlinear crystal in the source, the observed wavelengths of the signal photons change from 600 to 965 nm, corresponding to the idler wavelengths in 1186-4694 nm.
The high-precision self-calibration radiation reference source is currently the research focus of satellite remote sensing calibration. In order to meet the requirements of quantitative applications such as climate monitoring, low-light radiation metering and single photon source radiance measurement, in view of the application requirements and technical requirements of visible to near infrared low-light radiometer, a compact three-channel low-light radiance meter based on correlated photon self-calibration is designed. This design method can improve the measurement accuracy of low light irradiance by using objective physical effect instead of physical standard, reducing the cumulative error caused by standard transfer chain. The absolute calibration of the detector responsivity can be achieved by the spontaneous parameter down-conversion effect, and the absolute radiation observation can be achieved without relying on the external reference. Based on this study, combined with the special application requirements of radiance meter, a numerical model of spectral rate and geometric transmission characteristics of wide spectrum correlated photons is established, and two basic operating modes of self-calibration and radiation observation are determined. The interaction between 355 nm pump source and nonlinear medium generates three-wave mixing, and the correlated photons are generated by class I non-collinear spontaneous parametric downconversion, the combined effect of monochromatic pump photon flow and quantum vacuum noise on non-centrosymmetric nonlinear crystal makes each incident photon spontaneously split into two photons with lower energy with a certain probability, called signal photons and idle photons respectively, they have a wide sptrum distribution from pump wave frequency to lattice resonance frequency. Correlated photon source has the technical characteristics of time and space correlation, natural wide spectrum and absolute reproducibility, so it has high absolute accuracy. Integrated design of self-calibration and radiation observation can monitor and correct changes in response characteristics in real time, maintain long-term stability of response characteristics, and improve traceability and accuracy of observation data. This design method solve the key technologies such as preparation and value transfer of correlated photon sources, suppression of pump stray light, high precision and high efficiency coupling of correlated photons, UV radiation resistance of space single-photon detectors, packaging reinforcement technology of space single-photon detectors,self-calibration and integrated design of radiation observation. The spectral measurement range of the low-light radiance meter is from 460 nm to 1 550 nm, the measurement range of radiance is 1×10-9~1×10-6 W/(cm2·sr·nm). In the design, the integration, miniaturization and modularization of the whole system are considered, and the eight spectral bands are integrated into a three-channel structure, solving the preparation of wide spectrum dependent photon source, optical multiplexing of calibration optical path, radiation measurement, high precision coincidence measurement and full optical path calibration of radiance meter, and achieving high precision radiation observation from visible to near infrared and periodic self-calibration research targets. In the self-calibration mode, the multiplex optical path module periodically introduces the spontaneous parametric down-conversion correlated photons, and the photon counting and coincidence detection module are used to calibrate the absolute quantum efficiency of the three channels. In the radiation observation mode, the multiplex optical path module introduces the low-light level target radiation and obtains the absolute spectral radiance of the observation target in the band of 460~1 550 nm at the same time. The calibration coefficient obtained by the self-calibration mode is used to correct the observation results. The effects of link error limited by radiation reference value transfer, optical decay of optical path and electronic decay of optical path on the measurement accuracy of microradiance are fundamentally solved. The visible near-infrared band adopts free space coupling mode and the short-wave infrared band adopts multi-mode fiber coupling mode. Through design optimization analysis, the focusing spots of the first and second channels meet the 300 μm pixel requirement of Si single photon detector, and the focusing spot of the third channel meets the 62.5 μm core diameter and 0.22 numerical aperture requirement of multi-mode fiber, all of them can be received by the detector photosensitive surface, meeting the design objectives. The method based on correlated photon calibration does not need to trace the high-precision primary standard in the laboratory and the lengthy standard transfer chain. By using the correlated photon generated in the process of parametric down-conversion, the calibration source of time, space and polarization can be obtained, and the high-precision observation of the low-light spectrum radiance from visible to near infrared band can be realized. The solution to the scientific problem of low-light observation instrument in space platform measurement can obtain higher calibration accuracy, and play an important role in climate monitoring, low-light radiation metrology, single-photon source radiance measurement and so on.
Infrared (IR) spectroscopy and imaging are important tools in metrology, including material analysis, sensing and characterization. Although conventional methods of IR metrology are available, they face challenges related to the high cost and low efficiency of IR light sources and photodetectors. These challenges can be addressed by circumventing the need for IR-range components using tools and techniques of quantum optics. In this thesis, we describe a technique for IR measurements, which requires using only accessible light sources and detectors operating in the visible range. Our technique is based on the nonlinear interference of correlated photon pairs generated via spontaneous parametric down conversion (SPDC). In SPDC, a photon from the pump laser generates a pair of correlated photons within a nonlinear crystal. One photon of the pair can be generated in the visible range, and the other in the IR range. Two identical nonlinear crystals pumped by the same laser form the nonlinear interferometer, where interference of the visible SPDC photons can be observed. The interference pattern of the visible photons depends on amplitudes and phases of the IR photons, which are used to probe the properties of the medium under study. Hence, by observing the interference of the visible photons we infer the IR properties of the media, without direct measurements of IR light. We applied the nonlinear interference method to realize the IR spectroscopy, IR optical coherence tomography (OCT), IR imaging and IR polarimetry. In the IR spectroscopy experiment, we simultaneously and independently measured both refractive index and absorption coefficient of various samples in the IR range, while only detecting photons in the visible range. In IR OCT and IR imaging schemes, we measured the reflectivity of the interfaces of the sample, performed 3D raster and wide field imaging through opaque (in the visible range) materials. In the IR polarimetry, we measured the birefringence of the samples. We studied glass, organic polymer, Silicon and CO2 gas, but our method can be applied to a broad variety of samples. Our method is widely tunable and has high precision and accuracy over mid-IR wavelengths. This work paves the way for further practical adoption of the method in the field of IR metrology, without the need for IR grade detectors and sources.
The prerequisite for achieving precise mid-infrared (3 000~5 000 nm) radiation measurement is calibration. In recent years, the technology using correlated photons generated by Spontaneous Parametric Down-Conversion (SPDC) for calibration has attracted widespread attention as an absolute calibration method requiring no external standard transfer. This approach, based on an objective physical effect, enables self-calibration. However, limited by the absence of infrared single-photon detectors, research surveys indicate its primary applications have been confined to calibration within the visible-near-infrared spectral range. Up-conversion technology, as a novel infrared single-photon detection method, enables the detection of correlated photon signals in the mid-infrared band.This paper first introduces the principle and mathematical expression for determining channel detection efficiency through correlated photon calibration. Subsequently, an experimental optical path combining parametric down-conversion and up-conversion technologies was constructed, with detailed descriptions of the setup procedures, particularly emphasizing the principles of correlated photon focusing and beam combining. The experiment initially utilized a 775 nm laser to pump a Periodically Poled Lithium Niobate (PPLN) crystal, generating 1 005 nm/3 390 nm correlated photon pairs via SPDC. The 1 005 nm signal photons were routed through the trigger path, while the 3 390 nm idler photons were directed to the measurement path. To address the challenge of lacking mid-infrared single-photon detectors, the 3 390 nm idler photons in the measurement path were up-converted to 810 nm through sum-frequency generation with 1 064 nm pump light in another PPLN crystal. Silicon-based near-infrared single-photon detectors of the same model were used to detect the 1 005 nm and 810 nm photons separately. The outputs from both near-infrared single-photon detectors were connected to a Time-to-Digital Converter (TDC) for time-correlated coincidence measurements. Practical experimental issues including dead time, afterpulses, accidental coincidences, and differences in non-common optical paths were analyzed. A 3 390 nm laser was employed to measure the transmittance of non-common optical paths at 3 390 nm. Based on the modified expression for calculating channel efficiency in correlated photon calibration, the detection efficiency of the measurement path for 3 390 nm was determined by removing the influence of non-common optical path efficiency using the measured coincidence counts and trigger photon counts.The study further investigated the limitations on the area and solid angle of mid-infrared radiation in the measurement path. By comparing the acceptance areas and solid angles for mid-infrared radiation between the up-conversion section and the fiber-coupled collection section, it was concluded that the fiber-coupled collection component imposed the primary constraints on the solid angle and area of mid-infrared radiation. Combining the calibrated detection efficiency of the measurement path, an expression for calculating mid-infrared radiance from up-converted photon counts was derived.The calibrated system was used to measure the radiance of a cavity-type blackbody at 3 390 nm under temperatures of 125 ℃, 150 ℃, 175 ℃, and 200 ℃. Experimental results were compared with theoretical radiance values calculated using Planck's formula, revealing a maximum discrepancy of 4.3%. This demonstrates the potential application prospects of combining up-conversion and down-conversion technologies for absolute radiance measurement beyond 3 000 nm. Finally, possible causes for the observed discrepancies were analyzed, including potential uncalibrated blackbody emissivity and slight laser power fluctuations during the experiment. Future optimizations for the system were proposed, such as incorporating laser power stabilization modules, to further enhance measurement accuracy.
We develop the collinear optical scheme for absolute calibration of the spectral radiance of IR sources using quantum properties of spontaneous parametric down-conversion (SPDC) effect. Characteristics of spatial resolution and the spectral range of measurements attainable with AgGaS2crystal pumped at 785 nm are discussed. Results of calculations of the angle between the crystal optical axis and the pump wave vector, required to achieve collinear phase matching at target IR frequencies, are presented and verified experimentally by recording the frequency-angular distribution of SPDC signal in the crystal sample cut for the radiance measurement of external radiation at the wavelength of 6 μm.
The nonlinear process of spontaneous parametric down-conversion in the silver-gallium-sulfide crystal can generate highly non-degenerate photon pairs in near-infrared and mid-infrared spectral ranges. In this work, we demonstrate and characterize the tunable mid-infrared photon source in silver-gallium-sulfide. By angle tuning the phase matching condition of the nonlinear crystal, we can tune the wavelength of the generated photons in mid-infrared from 5.661 to 10.885 μm (from 1766 to 919 cm −1 ), while the correlated photons in the near-infrared are from 747.1 to 702.6 nm. The phase matching curve and the frequency-angular spectrum of mid-infrared photons were experimentally validated by measuring the properties of near-infrared photons. The brightness of the photon pair source was found to be (29.2± 1.1) mWMHz in the low-gain regime, exceeding the values reported in previous studies using silver-gallium-sulfide crystals. The wide tunability of the photon source in the mid-infrared range is important for hyperspectral imaging and sensing, and it is of significant interest for biomedical, chemical, and environmental applications.