Making use of the result given in the previous paper, this paper inyestigatefl the influence of intensity and detuning of the pump field on squeezing and gives the numerical calculated result.
We study the effects of squeezed pump fluctuations in the degenerate parametric amplifier on signal squeezing. We find, both through semiclassical calculations and through several detailed analytic methods, that pump squeezing is responsible for two competing processes: Reduced pump phase fluctuations improve limitations to squeezing; at the same time, increased pump intensity fluctuations can lead to a ``spillover'' of pump fluctuations onto negative pump phases and a consequent reduction in signal squeezing.
Summary form only given. The generation of quantum states of light, such as squeezed states, often relies on degenerate optical parametric amplification. The input signal in a degenerate optical parametric amplifier (DOPA) may be amplified or deamplified depending on the phase of the signal field relative to that of the pump field (/spl Delta//spl phi/=/spl phi//sub pump/-2/spl phi//sub signal/). We present the results of an accurate numerical DOPA model for the generation of amplitude-squeezed light with Gaussian pump and signal beams. We find that the widely accepted 3-dB limit imposed by the Gaussian beam profiles can actually be exceeded in the tight focusing regime.
We investigate the time evolution of squeezing in the signal mode of the undamped parametric amplifier. Both the degenerate and nondegenerate cases are considered. These are the simplest models that give limits to squeezing caused by both the intrinsic pump noise and pump depletion. Conflicting analytic expressions have been reported. We resolve this by the use of exact numerical methods, employing both number state and stochastic techniques. Our central result is that in both cases we find that the minimum in the squeezed quadrature variance scales as N${\mathrm{\ifmmode\bar\else\textasciimacron\fi{}}}^{\mathrm{\ensuremath{-}}1/2}$, where N\ifmmode\bar\else\textasciimacron\fi{} is the initial coherent pump photon number. This bound on the amount of squeezing obtainable, coupled with the loss in energy due to the conversion efficiency, serves to limit the phase information in the squeezed channel to no more than that of the coherent pump. We believe this to be a fundamental limit for using the squeezed radiation generated in coherently driven parametric amplifiers.
This thesis is primarily a theoretical study of degenerate parametric amplification as a means of generating squeezed-state light. i) A wideband traveling-wave formalism is developed for analyzing quantum mechanically a degenerate parametric amplifier. The formalism is based on spatial differential equations — spatial Langevin equations — that propagate temporal Fourier components of the field through the nonlinear medium. In addition to the parametric nonlinearity, the Langevin equations include absorption and associated fluctuations, dispersion, and pump quantum fluctuations. The dominant effects of dispersion and pump quantum fluctuations on the squeezing produced by a degenerate parametric amplifier are analyzed. ii) The wideband formalism of i) is used to carry out a more detailed analysis of the effects of phase mismatching. With the assumption of a lossless medium and a classical pump, we find that parametric amplification is capable of generating squeezed-state light over a wide band if materials with large χ(2) nonlinearities can be found, and that the squeezing bandwidth can be enhanced by phase mismatching away from degeneracy. iii) We consider again the effect of pump quantum fluctuations on the squeezing produced by parametric amplification. We perform discrete-mode calculations for a parametric amplifier with a quantum pump, and discuss some of the limitations of calculations of this sort in quantum optics. We derive stochastic differential equations (SDEs) for one- and two-mode parametric amplifiers, and from them obtain an iterative solution showing that pump quantum fluctuations impose a limitation on the degree of squeezing obtainable from a parametric amplifier. iv) A possible application of squeezing is considered; in particular, we study the effects of squeezing the intracavity noise in a laser oscillator. We solve the classical noise problem of a realistic laser model by making a bold — and possibly unrealizable — assumption, that the in-phase and quadrature Langevin sources which are responsible for the "noisiness" of the laser can be squeezed. We show that the effect of squeezing the in-phase quadrature is to reduce the phase noise, including the linewidth, of the laser but, due to amplitude-phase coupling, not to eliminate them altogether.
We demonstrate the dependence of the squeezing and anti-squeezing factors on the seed beam power at different pump beam noise levels. The results indicate that a seed field injected into the optical parametric amplifier (OPA) dramatically degenerates the squeezing factor due to noise coupling between the pump and seed fields, even if both the pump and seed fields reach the shot noise limit. The squeezing and anti-squeezing factors are immune to the pump beam noise due to no noise coupling when the system operates for the generation of squeezed vacuum states. The squeezing factor degrades gradually as the pump beam intensity noise and seed beam power is increased. The influence of the two orthogonal quadrature variations is mutually independent of each other.
We investigate the generation of amplitude-squeezed states with degenerate optical parametric amplifiers that are pumped by focused Gaussian beams. We present a model that facilitates the calculation of the squeezing level for an experimentally realistic configuration in which there is a Gaussian input signal beam that has the same confocal parameter and waist location as the Gaussian pump beam, with no restriction on the interaction length-to-confocal parameter ratio. We show that the 3-dB squeezing limit that was thought to be imposed by the Gaussian pump profile can be exceeded in the (previously uninvestigated) tight-focusing regime. We find the maximum possible amplitude squeezing in this regime to be 4.65 dB. However, it is possible to increase the squeezing level further by spatially filtering the tails of the output signal beam, resulting in squeezing levels in excess of 10 dB.