Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Coherence readout from supercontinua in multiple filaments: Experiments and supercomputer simulations

P. A. Zhokhov, Alexander A. Voronin, И. В. Федотов, Andrei B. Fedotov, Aleksei M. Zheltikov

Published Jan 17, 2013• 1 citation
Publisher

Abstract

Four-wave mixing of supercontinuum field wave forms with an ultrashort reference pulse is shown to retrieve the coherent components from multiple supercontinua and combine them into a beam whose spatial coherence is much higher than the spatial coherence of supercontinua in multiple filaments.
DOI
10.1103/physreva.87.013819

Related papers

Ultrahigh-time-resolution coherent transient spectroscopy with incoherent light

Norio Morita, Tatsuo Yajima

A new method of picosecond and femtosecond transient spectroscopy yielding information about ultrafast relaxation processes without requiring ultrashort light pulses is presented. It is based on the present theoretical analysis of the resonant degenerate four-wave-mixing process excited by two temporally incoherent light beams with wave vectors ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{1}$ and ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{2}$ which are originated from a single beam at frequency $\ensuremath{\omega}$ but have mutual time delay $\ensuremath{\tau}$. Under the assumption that the incoherent light field has Gaussian random complex amplitude and that the resonant material consists of the usual two-level atoms, the statistically averaged intensity of the output light field with ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{3}=2{\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{2}\ensuremath{-}{\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{1}$ at $\ensuremath{\omega}$ is calculated as a function of $\ensuremath{\tau}$. Even with the light having a much longer duration than both ${T}_{1}$ (the longitudinal relaxation time) and ${T}_{2}$ (the transverse relaxation time), the correlation trace, i.e., output intensity versus $\ensuremath{\tau}$, represents a decay profile determined mainly by ${T}_{2}$ for both homogeneously and inhomogeneously broadened transitions, as long as the light correlation time ${\ensuremath{\tau}}_{c}$ is much shorter than the relaxation times. The correlation trace does not always represent a single-exponential decay but is sometimes slightly deformed by the ${T}_{1}$ effect. However, it does not cause a significant error in the determination of ${T}_{2}$. Moreover, as $\frac{{T}_{2}}{{T}_{1}}\ensuremath{\rightarrow}0$, the trace becomes a single-exponential decay curve determined only by ${T}_{2}$. The feature of the results obtained by the present method is similar to that obtained by the conventional coherent transient spectroscopy with short pulses, such as the photon echo. The time resolution in the present method, however, is limited only by ${\ensuremath{\tau}}_{c}$ much shorter than the light duration. By regarding the incoherent light as a series of random ultrashort pulses, the present four-wave-mixing process is also interpreted as the ensemble of numerous transient four-wave-mixing processes caused by various combinations of these pulses.

Physical Review A•Nov 1, 1984•336 citations

A method for the coherence measurement of the supercontinuum source using Michelson interferometer

V. A. Semenova, A V Tsypkin, Путилин Сергей Эдуардович +1 more

Coherent properties of supercontinuum sources are highly significant for various applications, including low-coherence interferometry and optical frequency metrology. We propose a fast method for the spatial and temporal self-coherence of the SC measurement using Michelson interferometer without a mirror movement. Furthermore, we present self-coherence measurements of the supercontinuum, generated in microstructured fiber at 780 nm.

Journal of Physics Conference Series•Sep 17, 2014•2 citations

Frequency-time and time-space mappings with broadband and supercontinuum chirped pulses in coherent wave mixing and pump-probe

Lomonosov Moscow

Broadband and supercontinuum pulses with a lin- ear chirp define a linear transform, mapping the difference between the instantaneous frequencies of pump pulses onto the delay time between these pulses. This delay between the pump pulses can be then mapped onto the spatial coordinate with the use of a broad-beam wave-mixing or pump-probe geometry. The new possibilities offered by these mappings for four-wave-mixing techniques are discussed. The spectral and temporal resolution of chirped-pulse wave-mixing and pump- probe techniques are examined. Single-shot multidimensional wave-mixing techniques using broadband and supercontinuum chirped pulses are discussed.

•Jan 1, 2003•0 citations

Second-order coherence of supercontinuum

Goëry Genty, Minna Surakka, Jari P. Turunen +1 more

Using second-order coherence theory of nonstationary light we show that supercontinuum can be split into quasi-coherent and quasi-stationary parts. Our results opens the route for a universal definition of the coherence degree for broadband sources.

•Jan 1, 2011•0 citations

Broadband degenerate four-wave-mixing measurements

Stanislav G. Rozouvan

The nonlinear signal in a degenerate four-wave mixing experiment as a result of diffraction of a spatially distributed third-order nonlinearity is studied theoretically. The approach has been applied for the case of monochromatic and ultrashort pulses. As a consequence, the degenerate four-wave mixing signal is found to be independent of light-coherence parameters and cannot be explained as a product of diffraction on a dynamic grating. In this model only the fast component of the signal (the coherent artifact) is related directly to third-order nonlinear processes. The main features (the origins, temporal shapes, dependencies of pump intensity, and modulation effects) of the coherent artifact and a slow-decay component are discussed theoretically and experimentally.

Journal of the Optical Society of America B•Aug 1, 2000•2 citations

Multiple-quantum 2D spectroscopy of many-body correlations in GaAs quantum wells

Daniel B. Turner, Katherine W. Stone, Patrick Wen +2 more

Multiple-quantum two-dimensional Fourier transform optical (2D FTOPT) spectroscopy was developed and conducted on GaAs quantum wells. Spatiotemporal femtosecond pulse shaping was used to control the optical phases and time delays of ultrashort pulses in multiple non-collinear beams so that fully coherent four-wave and higher-order mixing measurements could be conducted without delay stages, multiple interferometers, or any active phase control. Coherences of biexcitons, unbound but correlated exciton pairs, and excitons undergoing rephasing were observed directly.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 11, 2010•0 citations
A new method of picosecond and femtosecond transient spectroscopy yielding information about ultrafast relaxation processes without requiring ultrashort light pulses is presented. It is based on the present theoretical analysis of the resonant degenerate four-wave-mixing process excited by two temporally incoherent light beams with wave vectors ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{1}$ and ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{2}$ which are originated from a single beam at frequency $\ensuremath{\omega}$ but have mutual time delay $\ensuremath{\tau}$. Under the assumption that the incoherent light field has Gaussian random complex amplitude and that the resonant material consists of the usual two-level atoms, the statistically averaged intensity of the output light field with ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{3}=2{\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{2}\ensuremath{-}{\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{1}$ at $\ensuremath{\omega}$ is calculated as a function of $\ensuremath{\tau}$. Even with the light having a much longer duration than both T1{T}_{1}T1​ (the longitudinal relaxation time) and T2{T}_{2}T2​ (the transverse relaxation time), the correlation trace, i.e., output intensity versus $\ensuremath{\tau}$, represents a decay profile determined mainly by T2{T}_{2}T2​ for both homogeneously and inhomogeneously broadened transitions, as long as the light correlation time ${\ensuremath{\tau}}_{c}$ is much shorter than the relaxation times. The correlation trace does not always represent a single-exponential decay but is sometimes slightly deformed by the T1{T}_{1}T1​ effect. However, it does not cause a significant error in the determination of T2{T}_{2}T2​. Moreover, as $\frac{{T}_{2}}{{T}_{1}}\ensuremath{\rightarrow}0$, the trace becomes a single-exponential decay curve determined only by T2{T}_{2}T2​. The feature of the results obtained by the present method is similar to that obtained by the conventional coherent transient spectroscopy with short pulses, such as the photon echo. The time resolution in the present method, however, is limited only by ${\ensuremath{\tau}}_{c}$ much shorter than the light duration. By regarding the incoherent light as a series of random ultrashort pulses, the present four-wave-mixing process is also interpreted as the ensemble of numerous transient four-wave-mixing processes caused by various combinations of these pulses.
Broadband and supercontinuum pulses with a lin- ear chirp define a linear transform, mapping the difference between the instantaneous frequencies of pump pulses onto the delay time between these pulses. This delay between the pump pulses can be then mapped onto the spatial coordinate with the use of a broad-beam wave-mixing or pump-probe geometry. The new possibilities offered by these mappings for four-wave-mixing techniques are discussed. The spectral and temporal resolution of chirped-pulse wave-mixing and pump- probe techniques are examined. Single-shot multidimensional wave-mixing techniques using broadband and supercontinuum chirped pulses are discussed.
The nonlinear signal in a degenerate four-wave mixing experiment as a result of diffraction of a spatially distributed third-order nonlinearity is studied theoretically. The approach has been applied for the case of monochromatic and ultrashort pulses. As a consequence, the degenerate four-wave mixing signal is found to be independent of light-coherence parameters and cannot be explained as a product of diffraction on a dynamic grating. In this model only the fast component of the signal (the coherent artifact) is related directly to third-order nonlinear processes. The main features (the origins, temporal shapes, dependencies of pump intensity, and modulation effects) of the coherent artifact and a slow-decay component are discussed theoretically and experimentally.
Multiple-quantum two-dimensional Fourier transform optical (2D FTOPT) spectroscopy was developed and conducted on GaAs quantum wells. Spatiotemporal femtosecond pulse shaping was used to control the optical phases and time delays of ultrashort pulses in multiple non-collinear beams so that fully coherent four-wave and higher-order mixing measurements could be conducted without delay stages, multiple interferometers, or any active phase control. Coherences of biexcitons, unbound but correlated exciton pairs, and excitons undergoing rephasing were observed directly.