Physical Review A

Photon-scattering-rate measurement of atoms in a magneto-optical trap

Kais Jooya, Nam Musterer, Kirk W. Madison, James L. Booth

Published Dec 2, 2013• 9 citations
Publisher

Abstract

We present a technique for empirically determining the photon scattering rate of atoms in a magneto-optical trap (MOT). An accurate measurement of the scattering rate provides a way to accurately determine the number of atoms in the MOT, the excited-state fraction, and the in situ light intensity experienced by the atoms in the trap. We validate this technique for determining the scattering rate by comparing the atom number determined by the fluorescence emitted by atoms in a MOT with an independent and unrelated measure of the number determined by an absorption measurement of an optical pumping beam. We also observe minor deviations from the two-level model for the single-photon scattering rate and extend our analysis to a four-level model. The main advantage of the method described here is that it provides a simple way of determining the photon scattering rate of the MOT empirically and, thus, of evaluating the atom number from fluorescence measurements more accurately.

DOI
10.1103/physreva.88.063401

Related papers

Determination of the atom’s excited-state fraction in a magneto-optical trap

Yue Guo Shen

This thesis introduces an empirical method for determining and controlling the excited-state fraction of atoms in a magneto-optical trap (MOT), which is essential for the use of cold atoms as a sensor when they are held in a MOT since their interactions with other particles and fields are quantum state dependent. A four-level theoretical atomic model was used to describe the transitions of the atoms in a MOT, and the fluorescence emitted from a fixed number of atoms under different laser conditions were measured to determine the saturation parameters empirically. Two saturation parameters P_sat= 1.15 (0.06) mW and P_r,sat= 2.05 (0.59) mW were successfully extracted from the model, and the excited-state fraction in the four-level model was accurately calculated as a function of the MOT trap parameters, which ranges from 0.045 to 0.415 for the experimental settings currently available. We also observed minor deviations from the four-level model for the photon scattering rate, and a hypothesis of atom pinning under high powers was proposed to explain the problem. We plan to use this simple excited-state fraction determination method to distinguish the ground and excited state collision cross section of Rubidium atoms with species in residual gas of the vacuum. This is the first step to establishing atom loss rates from a MOT as an atomic primary pressure standard.

•Jan 1, 2018•0 citations

Model-independent measurement of the excited fraction in a magneto-optical trap

M. H. Shah, H. A. Camp, M. L. Trachy +3 more

In many experiments involving a magneto-optical trap (MOT) it is of great importance to know the fraction of atoms placed in an excited state due to the trapping process. Generally speaking, researchers have had to use overly simplistic and untested models to estimate this fraction. In this work, the excited fractions of $^{87}\mathrm{Rb}$ atoms in a MOT are directly measured using a charge transfer technique, for a range of MOT parameters. Simple models are then fit to the measured fractions. Using the results of this work, the excited fraction of $^{87}\mathrm{Rb}$ atoms trapped in a MOT can be accurately estimated with knowledge of only the trapping laser intensity and detuning. The results are, at most, only weakly dependent on other MOT parameters.

Physical Review A•May 31, 2007•35 citations

Simple technique for directly and accurately measuring the number of atoms in a magneto-optical trap

Ying-Cheng Chen, Yean-an Liao, Long Hsu +1 more

We have systematically studied a simple technique that accurately determines number of atoms in a magneto-optical trap. Absorption energy of a laser field that interacts with cold atoms is a direct measurement of atom number. The measured energy neither depends on the detuning, intensity, and polarization of the laser field nor is affected by other system parameters. Our work also demonstrates that such technique can be applied to study the phenomenon of coherent population trapping.

Physical Review A•Aug 13, 2001•31 citations

Model-Free Measurement of the Excited-State Fraction in a $^{85}$Rb Magneto-Optical Trap

Hai Truong Nguyen, Goga Veshapedze, Chris Verzani +3 more

In many experiments involving magneto-optical traps (MOTs), it is imperative to know the fraction of atoms left in an excited state by the cooling and trapping lasers. In most cases, researchers have used formulas that were derived for simple 2-level systems interacting with a single beam of light having a well-defined polarization, and in the absence of magnetic or electric fields. However a MOT environment is much more complex than this. Here we directly measure the excited fraction in a MOT of 85Rb atoms in a model-independent manner for a wide range of trapping conditions. We then fit our measured fractions to an ansatz based on a simple model. Knowing only the trapping laser's total intensity and detuning from resonance, one can then use this ansatz to accurately predict the excited fraction. The work is a companion piece to similar measurements on a MOT of 87Rb.

Bulletin of the American Physical Society•Jun 4, 2014•2 citations

Single-atom counting in a two-color magneto-optical trap

Martin Schlederer, Alexandra Mozdzen, Thomas Lompe +1 more

Recording the fluorescence of a magneto-optical trap (MOT) is a standard tool for measuring atom numbers in experiments with ultracold atoms. When trapping few atoms in a small MOT, the emitted fluorescence increases with the atom number in discrete steps, which allows one to measure the atom number with single-particle resolution. Achieving such single-particle resolution requires stringent minimization of stray light from the MOT beams, which is very difficult to achieve in experimental setups that require in-vacuum components close to the atoms. Here, we present a modified scheme that addresses this issue: Instead of collecting the fluorescence on the MOT (D2) transition, we scatter light on an additional probing (D1) transition and collect this fluorescence with a high-resolution microscope while filtering out the intense MOT light. Using this scheme, we are able to reliably distinguish up to 17 $^{40}\mathrm{K}$ atoms with classification fidelities of $\ensuremath{\sim}98%$ for up to 5 atom numbers and fidelities of more than 85% for up to 17 atoms.

arXiv:2011.10081•Physical Review A•Mar 12, 2021•3 citations

Model-free measurement of the excited-state fraction in a Rb85 magneto-optical trap

G. Veshapidze, J. Bang, C. W. Fehrenbach +2 more

In many experiments involving magneto-optical traps (MOTs), it is imperative to know the fraction of atoms left in an excited state by the cooling and trapping lasers. In most cases, researchers have used formulas that were derived for simple two-level systems interacting with a single beam of light having a well-defined polarization, and in the absence of magnetic or electric fields. However, a MOT environment is much more complex than this. Here we directly measure the excited fraction in a MOT of $^{85}\mathrm{Rb}$ atoms in a model-independent manner for a wide range of trapping conditions. We then fit our measured fractions to an ansatz based on a simple model. Knowing only the trapping laser's total intensity and detuning from resonance, one can then use this ansatz to accurately predict the excited fraction. The work is a companion piece to similar measurements on a MOT of $^{87}\mathrm{Rb}$.

Physical Review A•May 27, 2015•10 citations
We present a technique for empirically determining the photon scattering rate of atoms in a magneto-optical trap (MOT). An accurate measurement of the scattering rate provides a way to accurately determine the number of atoms in the MOT, the excited-state fraction, and the in situ light intensity experienced by the atoms in the trap. We validate this technique for determining the scattering rate by comparing the atom number determined by the fluorescence emitted by atoms in a MOT with an independent and unrelated measure of the number determined by an absorption measurement of an optical pumping beam. We also observe minor deviations from the two-level model for the single-photon scattering rate and extend our analysis to a four-level model. The main advantage of the method described here is that it provides a simple way of determining the photon scattering rate of the MOT empirically and, thus, of evaluating the atom number from fluorescence measurements more accurately.
This thesis introduces an empirical method for determining and controlling the excited-state fraction of atoms in a magneto-optical trap (MOT), which is essential for the use of cold atoms as a sensor when they are held in a MOT since their interactions with other particles and fields are quantum state dependent. A four-level theoretical atomic model was used to describe the transitions of the atoms in a MOT, and the fluorescence emitted from a fixed number of atoms under different laser conditions were measured to determine the saturation parameters empirically. Two saturation parameters P_sat= 1.15 (0.06) mW and P_r,sat= 2.05 (0.59) mW were successfully extracted from the model, and the excited-state fraction in the four-level model was accurately calculated as a function of the MOT trap parameters, which ranges from 0.045 to 0.415 for the experimental settings currently available. We also observed minor deviations from the four-level model for the photon scattering rate, and a hypothesis of atom pinning under high powers was proposed to explain the problem. We plan to use this simple excited-state fraction determination method to distinguish the ground and excited state collision cross section of Rubidium atoms with species in residual gas of the vacuum. This is the first step to establishing atom loss rates from a MOT as an atomic primary pressure standard.
In many experiments involving a magneto-optical trap (MOT) it is of great importance to know the fraction of atoms placed in an excited state due to the trapping process. Generally speaking, researchers have had to use overly simplistic and untested models to estimate this fraction. In this work, the excited fractions of 87Rb^{87}\mathrm{Rb}87Rb atoms in a MOT are directly measured using a charge transfer technique, for a range of MOT parameters. Simple models are then fit to the measured fractions. Using the results of this work, the excited fraction of 87Rb^{87}\mathrm{Rb}87Rb atoms trapped in a MOT can be accurately estimated with knowledge of only the trapping laser intensity and detuning. The results are, at most, only weakly dependent on other MOT parameters.
Model-Free Measurement of the Excited-State Fraction in a 85^{85}85Rb Magneto-Optical Trap
In many experiments involving magneto-optical traps (MOTs), it is imperative to know the fraction of atoms left in an excited state by the cooling and trapping lasers. In most cases, researchers have used formulas that were derived for simple 2-level systems interacting with a single beam of light having a well-defined polarization, and in the absence of magnetic or electric fields. However a MOT environment is much more complex than this. Here we directly measure the excited fraction in a MOT of 85Rb atoms in a model-independent manner for a wide range of trapping conditions. We then fit our measured fractions to an ansatz based on a simple model. Knowing only the trapping laser's total intensity and detuning from resonance, one can then use this ansatz to accurately predict the excited fraction. The work is a companion piece to similar measurements on a MOT of 87Rb.
Recording the fluorescence of a magneto-optical trap (MOT) is a standard tool for measuring atom numbers in experiments with ultracold atoms. When trapping few atoms in a small MOT, the emitted fluorescence increases with the atom number in discrete steps, which allows one to measure the atom number with single-particle resolution. Achieving such single-particle resolution requires stringent minimization of stray light from the MOT beams, which is very difficult to achieve in experimental setups that require in-vacuum components close to the atoms. Here, we present a modified scheme that addresses this issue: Instead of collecting the fluorescence on the MOT (D2) transition, we scatter light on an additional probing (D1) transition and collect this fluorescence with a high-resolution microscope while filtering out the intense MOT light. Using this scheme, we are able to reliably distinguish up to 17 40K^{40}\mathrm{K}40K atoms with classification fidelities of $\ensuremath{\sim}98%$ for up to 5 atom numbers and fidelities of more than 85% for up to 17 atoms.
In many experiments involving magneto-optical traps (MOTs), it is imperative to know the fraction of atoms left in an excited state by the cooling and trapping lasers. In most cases, researchers have used formulas that were derived for simple two-level systems interacting with a single beam of light having a well-defined polarization, and in the absence of magnetic or electric fields. However, a MOT environment is much more complex than this. Here we directly measure the excited fraction in a MOT of 85Rb^{85}\mathrm{Rb}85Rb atoms in a model-independent manner for a wide range of trapping conditions. We then fit our measured fractions to an ansatz based on a simple model. Knowing only the trapping laser's total intensity and detuning from resonance, one can then use this ansatz to accurately predict the excited fraction. The work is a companion piece to similar measurements on a MOT of 87Rb^{87}\mathrm{Rb}87Rb.