Physical Review
Mean Lives of Mercury Lines λ2537 and λ1849
Paul H. Garrett
Abstract
The mean life of the mercury line $\ensuremath{\lambda}2537$ was measured by the alternating voltage method previously described by Webb. The radiation was excited in a quartz tube by impact with electrons from a hot cathode. The photoelectric system was contained in a separate tube also of quartz. The photoelectric surface was zinc evaporated on a nickel plate. Measurements of the apparent life were made with diminishing mercury vapor pressures until further reduction of pressure produced no change in the measured rate of decay of the radiation. At these low pressures (below 3\ifmmode\times\else\texttimes\fi{}${10}^{\ensuremath{-}4}$ mm, for the geometry used) the absorption and reemission of the radiation was negligible and the true life of a single excitation process was measured. This was found to be 1.08\ifmmode\times\else\texttimes\fi{}${10}^{\ensuremath{-}7}$ sec. with an estimated precision of one percent.Absorption coefficient of $\ensuremath{\lambda}1849$. An absorption cell with a one mm thick absorbing layer of mercury vapor was mounted so as to move in and out between the excitation and photoelectric tubes used in the above measurements. The absorption of $\ensuremath{\lambda}1849$ was measured at pressures such that the absorption of $\ensuremath{\lambda}2537$ was negligible. From this the atomic absorption coefficient for the main component of the line was found to be 6.2\ifmmode\times\else\texttimes\fi{}${10}^{\ensuremath{-}11}$ from which the mean life of the $2^{1}P_{1}$ state was calculated to be 2.9\ifmmode\times\else\texttimes\fi{}${10}^{\ensuremath{-}10}$ sec. with an estimated precision of 25 percent.