Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Frontiers in Optics

Observation of spectral interference for any path difference in an interferometer

Luis José Salazar-Serrano, Alejandra Valencia, Juan P. Torres

Published Jan 1, 2014• 1 citation
Publisher

Abstract

We report experimental observation of spectral interference in a Michelson interferometer, regardless of the relationship between the temporal path difference and the spectral width of an input pulse, by using a weak value amplification scheme.
DOI
10.1364/fio.2014.fm4d.6

Related papers

Observation of spectral interference for any path difference in an interferometer

Luis José Salazar-Serrano, Alejandra Valencia, Juan P. Torres

We report the experimental observation of spectral interference in a Michelson interferometer, regardless of the relationship between the temporal path difference introduced between the arms of the interferometer and the spectral width of the input pulse. This observation is possible by introducing the polarization degree of freedom into a Michelson interferometer using a typical weak value amplification scenario.

arXiv:1404.1482•Optics Letters•Jul 23, 2014•24 citations

Measurement of sub-pulse-width temporal delays via spectral interference induced by weak value amplification

Luis José Salazar-Serrano, Davide Janner, Nicolas Brunner +2 more

We present experimental results of a scheme based on the concepts of weak measurements and weak value amplification to measure temporal delays, much smaller than the pulse width, by means of spectral interference

•Jan 1, 2014•1 citation

Experimental Demonstration of Spectral Modification in a Mach-Zehnder Interferometer

D. Narayana Rao, Vinay Kumar

We illustrate here the experimental verification of the spectral modulation arising from interference of light beams having different degrees of correlation in a Mach-Zehnder interferometer for which the theoretical study was done by Agarwal and James (1993, J. mod. Optics, 40 1431). Through a theoretical fitting for the observed spectral modification, path difference between the beams in the two arms is calculated and compared with the experimental values.

Journal of Modern Optics•Sep 1, 1994•28 citations

Extension of the input–output relation for a Michelson interferometer to arbitrary coherent-state light sources: Gravitational-wave detector and weak-value amplification

Kouji Nakamura, Masa‐Katsu Fujimoto

arXiv:1705.09768•Annals of Physics•Mar 18, 2018•3 citations

Amplification of Optical Pulse Delays using Weak Measurements

Mohammad Mirhosseini, Omar S. Magaña‐Loaiza, Mehul Malik +1 more

A novel scheme for super-sensitive measurement of optical pulse delays is proposed based on the concept of weak-value amplification. We discuss an experimental implementation of this technique utilizing a Mach-Zehnder interferometer.

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting•Jan 1, 2013•0 citations

On the formation of white-light interference fringes

Attila Pál Kovács, Katalin Varjú, K. Osvay +1 more

We describe an experiment in which the white-light interference fringes appearing at the output of a Michelson interferometer are observed through a spectrograph. In this manner the relative positions of monochromatic interference fringes come into sight and it allows a better understanding of the formation of the white-light fringes. A simple model is described for determining the shape of the spectrally resolved white-light interference fringes. An expression for the relationship between the slope of the fringes and the arm length difference of the interferometer is derived and is demonstrated experimentally. In addition, an intuitive explanation based on this experiment is given for the washing out of the white-light fringes.

American Journal of Physics•Nov 1, 1998•10 citations
We describe an experiment in which the white-light interference fringes appearing at the output of a Michelson interferometer are observed through a spectrograph. In this manner the relative positions of monochromatic interference fringes come into sight and it allows a better understanding of the formation of the white-light fringes. A simple model is described for determining the shape of the spectrally resolved white-light interference fringes. An expression for the relationship between the slope of the fringes and the arm length difference of the interferometer is derived and is demonstrated experimentally. In addition, an intuitive explanation based on this experiment is given for the washing out of the white-light fringes.