We propose an operating condition for an optically pumped scalar atomic magnetometer with a unique band-pass frequency response. Under this operating condition, the signal response of the magnetometer is increased threefold around a nonzero resonance frequency. The resonance frequency is equal to the detuning between the Larmor frequency and the frequency of the oscillating magnetic field used for excitation. The resonance is explained in terms of the characteristics of the first-order perturbation expansion of the Bloch equation for a modulated bias magnetic field. The scalar magnetometer provides an enhanced magnetic response around its resonance frequency even beyond the cutoff frequency, which is defined as the inverse of the phase relaxation time of the spin polarization.
We propose an operating condition for an optically pumped scalar atomic magnetometer with a unique band-pass frequency response. Under this operating condition, the signal response of the magnetometer is increased threefold around a nonzero resonance frequency. The resonance frequency is equal to the detuning between the Larmor frequency and the frequency of the oscillating magnetic field used for excitation. The resonance is explained in terms of the characteristics of the first-order perturbation expansion of the Bloch equation for a modulated bias magnetic field. The scalar magnetometer provides an enhanced magnetic response around its resonance frequency even beyond the cutoff frequency, which is defined as the inverse of the phase relaxation time of the spin polarization.
It is demonstrated that a spin-exchange relaxation-free (SERF) atomic magnetometer can be used for scalar measurements with no additional hardware. Because of relaxation processes, an ensemble of alkali atoms needs a constant supply of polarized photons by a pump beam to maintain a polarized state. If the pump beam is shuttered off, the system decays to its equilibrium state. For a low enough relaxation rate and with a magnetic field present, the system will exhibit oscillations at its natural frequencies. In a SERF magnetometer, it happens at the Zeeman resonance frequency of the atoms (Larmor frequency). Thus, shuttering off the pump beam reveals oscillations at the Larmor frequency. From this frequency, one can deduce the scalar value of the applied magnetic field. As a result, all-optical scalar measurements can be performed. At the same time, either one or two vector components of the applied field can be measured by using one or two orthogonal probe beams, respectively. In a low-polarization SERF regime, the ground state can be well described by the Bloch equations for the electron spin polarization. By solving the time-dependent Bloch equations [neglecting the diffusion term and assuming that the nuclear slowing-down factor q(P) is constant], the oscillation frequency of the system is obtained. From this frequency, the scalar value of the applied magnetic field is derived. It is shown that applied fields down to 1 nT can be measured with a 0.1% relative uncertainty. Fields down to 50 pT can be measured with a 10% relative uncertainty. The time dependence acquired in the “off” periods is strongly correlated with the Zeeman sublevels population of the atomic ground state and reveals its spin dynamics.
In order to measure a weak alternating magnetic field, an optically-pumped Rb magnetometer based on pump-probe structure is investigated and demonstrated. The pumping light and probing light propagate along the z axis and x axis, respectively. A constant polarization magnetic field along the pumping light is applied, which not only stabilizes the polarization of Rb atoms but also tunes resonance frequency of Rb atoms. When a weak alternating magnetic field is applied perpendicularly to the constant magnetic field, the magnetic moment will tip off the z axis and rotate around the z axis. And then the polarization plane of probing light is modulated correspondingly. The x component of the magnetic moment can be obtained with a balanced detector. As a result, a signal proportional to weak alternating magnetic field can be obtained.In order to obtain the magnetic response of the magnetometer, we analyze the signal amplitude as a function of polarization magnetic field strength B0 and transverse relaxation time 2 with numerical simulation. The amplitude-frequency response of the magnetometer is determined mainly by two parameters, namely cutoff frequency c=1/2 and resonance frequency 0= B0, where is the gyromagnetic ratio of Rb atom. At low frequency, that is a0 and a 0c2, the magnetometer has a flat response, here a is the frequency of the weak alternating magnetic field. If 0c, the signal amplitude will be large for large 0 or small c. For a given c, the peak response appears at 0=c. In the vicinity of resonance frequency, if c0, a peak will appear and if c 0, no peak occurs. At high frequency, the amplitude will decrease with the increase of a.We verify the above analyses in experiment. A vapor cell with a short transverse relaxation time is used to obtain large frequency response bandwidth. Through optimizing the powers and frequencies of pumping laser and probing laser, high polarization and detection sensitivity of atomic spin can be obtained. Moreover, through choosing an appropriate polarization magnetic field, the magnetometer can be maximally sensitive to the magnetic field to be measured. The experimental results show that the magnetometer has a sensitivity of about m 0.2; pT/HzHz and bandwidth of about 3.5 kHz. It can be used to detect low field magnetic resonance and high frequency abnormal physical phenomena.
A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.
A dip of the transverse component of the magnetic moment as a function of resonance frequency-detuning will emerge when the intensity of oscillating magnetic field exceeds a specific value, which is demonstrated theoretically and experimentally. The linewidth of magnetic-resonance signal can be much smaller than when the M x – M R magnetometer operates on condition that the intensity of oscillating magnetic field is smaller than this specific value, and the M x – M R magnetometer can possess a much higher signal-to-noise ratio. The experimental result shows that the sensitivity of M x – M R magnetometer can be improved by an order of magnitude under this condition.
The response of a spin exchange relaxation free atomic magnetometer to a repetitive short-pulsed pump was investigated. Quantum sub-resonances at a repetition rate of 1/n of the Larmor frequency of the magnetic field inside the shield are experimentally observed and theoretically explained. This is a type of synchronization phenomenon. Investigations in single alkali atom cells and mixed alkali atoms of K and Rb are presented. In the latter, one species is pumped while the probe is on the other species polarized by spin exchange. The effect of spin destruction, spin exchange, and collisions is studied in order to account for the width of the resonances. Quantum calculations of a three-level Λ model for this phenomenon exhibit a dip at the resonance frequency in the absorption spectrum for both cases of pulsed and cw pump modes and an evidence for electromagnetically induced transparency.
Optically pumped radio frequency (RF) atomic magnetometers have been shown to have an improved sensitivity over standard tuned coils for frequencies less than 50 MHz, making these RF magnetometers attractive for the detection of nuclear quadrupole resonance (NQR) and low-field nuclear magnetic resonance (NMR) signals. In an atomic magnetometer a linearly polarized probe beam measures, through Faraday rotation, the transverse atomic magnetization induced by the resonant RF signal. The resonance, or Larmor, frequency of the magnetometer is easily tuned with a small magnetic field. We construct an atomic magnetometer based on a potassium vapor cell with a measured sensitivity of 0.22 ± 0.02 fT/ √ Hz and a detection bandwidth of 334 ± 11 Hz when tuned to 423 kHz, giving a Q of over 1200. While high Q magnetometers are sensitive to weak magnetic fields, they are also sensitive to magnetic transients, such as those associated with the excitation pulses needed for magnetic resonance. The ringing created by such transients can obscure the signal of interest. This is particularly detrimental for magnetic resonance signals that decay faster than the transverse relaxation rate. We demonstrate that by feeding back part of the optical signal to orthogonal electromagnetic coils, this unwanted ringing can be quickly damped out leaving the magnetometer ready for the detection of the signal. This negative feedback as applied to the K spins is called spin-damping and can be used to relax the K atoms faster by more than two orders of magnitude. Using spin-damping we reduce the dead-time before data acquisition from 0.8 to 0.2 ms in the detection of NQR signals from ammonium nitrate, one of the so-called fertilizer bomb explosives with an NQR frequency of 423 kHz. Furthermore, we discover that spin-damping can not only be used to suppress signals, it can also be used to suppress noise. We show that it can be used to suppress both environmental noise and more fundamental quantum noise, such as photon shot and spin projection noise. The latter suppression opens the door for its use in quantum control to initialize spin systems before measurements. For phase-sensitive detection, as is often used in magnetic resonance, spin-damping suppresses signal and noise in such a way as to increase the sensitivity bandwidth of the magnetometer. We prove, both theoretically and experimentally, that it is possible to increase the magnetometer detection bandwidth by a factor of 3 or more without significant loss in sensitivity. Such gains in bandwidth for a high Q magnetometer translate into savings in detection time, particularly for substance detection where the frequency of the signal of interest may not be completely known.