Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Single-atom localization via resonance-fluorescence photon statistics

Shuai Yang, M. Al-Amri, Muhammad Suhail Zubairy

Published Feb 23, 2012• 17 citations
Publisher

Abstract

We present a scheme for subwavelength single-atom localization that is based on the photon statistics measurement of the resonance fluorescence from the two-level atomic system. The photon number distribution of the resonance fluorescence depends on the position of the atom inside the standing-wave driving field via the position-dependent Rabi frequency. We show that this position-dependent Rabi frequency can be used to localize the atom within the subwavelength region.

DOI
10.1103/physreva.85.023831

Related papers

Atom localization via resonance fluorescence

Sajid Qamar, Shi-Yao Zhu, Muhammad Suhail Zubairy

We propose a simple scheme of atom localization based on resonance fluorescence from a standing-wave field. The Rabi frequency is position dependent and therefore the spontaneously emitted photon carries the information of the atomic center-of-mass motion. This leads to atom localization even during the flight through the standing-wave field.

Physical Review A•May 11, 2000•197 citations

Atom localization of a two-level pump-probe system via the absorption spectrum

Mostafa Sahrai, Mohammad Mahmoudi, Reza Kheradmand

We propose a scheme to localize a two-level atom inside a classical standing wave field conditioned upon the measurement of the frequency of a weak probe field at resonance excitation of a two-level atomic system. Inside the classical standing wave field, the interaction between the atom and the field is position-dependent due to the Rabi frequency of the driving field; hence, as the absorption frequency of the probe field is measured, the position of an atom inside the classical standing wave field will be determined. The effects of atomic parameters on atom localization are then discussed.

Laser Physics•Jan 1, 2007•14 citations

Atom localization via absorption spectrum

Mostafa Sahrai

We propose a scheme to localize an atom in a three-level A-type configuration inside a classical standing wave field conditioned upon the measurement of frequency of a weak probe field. Inside the classical standing wave field, the interaction between atom and the field is position-dependent due to the Rabi frequency of the driving field; hence, as the absorption frequency of the probe field is measured, the position of an atom inside the classical standing wave field will be determined. Localizing of an atom via absorption spectrum occurs during its motion inside the standing wave field. An investigation of the probe field frequency shows that the degree of localization depends on interaction parameters such as detuning, phase difference between applied fields, and Rabi frequency of the driving field.

Laser Physics•Feb 1, 2007•11 citations

SPECTROSCOPIC TECHNIQUES FOR SINGLE ATOM LOCALIZATION

Sajid, Qamar

Entanglement of the atom and field leads towards the measurement of the state of the atom or field depending on the kind of measurement made. Taking advantage of this fact, we propose spectroscopic methods for the single atom localization within the subwavelength domain of the optical standing wave field. \n \nWhen a two-level atom interacts with some intense radiation field the spectrum of the scattered light signal exhibits a three-peak Mollow spectrum. We propose a scheme of atom localization based on the resonance fluorescence from a two-level atom interacting with a standing wave field. The Rabi frequency is considered to be position dependent and therefore, the spontaneously emitted photon carries the information about the center-of-mass motion of the atom. This leads to the localization of the single atom by measuring the frequency of the spontaneously emitted photon even during the passage of the atom through the standing wave field. We predict a spatial resolution in position information of up to λ/60 where λ is the optical wavelength. \n \nDetuning of the coherent field with the atomic transition plays an important role in the characterization of the peaks present in the Autler- Townes spectrum of a three-level atom. Strong line narrowing is observed in one of the peaks of the Autler- Townes doublet depending on the choice of the detuning. We investigate how this detuning effects the position information of the atom inside the standing wave field in upper-level and lower-level coupling schemes of Autler- Townes microscopy. We show an enhancement in precision position measurement by factor of at least 4 in upper-level coupling scheme due to the quantum interference phenomenon. This enhancement is not observed in lower-level coupling scheme where the quantum interference is not taking place. \n \nWe also consider a system where a three-level atom is interacting with a monochromatic radiation field in such a way that the decay takes place from upper level to the intermediate level with a rate T and from intermediate level to lower level at a rate γ. This type of system exhibits a non stationary scattered light signal. We report the results of the spontaneous emission spectrum for non stationary scattered light signal by using the definition of time-dependent physical spectrum. This is a rare example of problems where time-dependent physical spectrum can be calculated exactly. We study the characteristics of the spontaneous spectrum for a resonant and off-resonant case and show that this physical spectrum recovers the results of earlier work quite successfully. We also show that the decay rate r disturbs the atomic coherence and finally eliminates the dark line from the center of the spontaneous spectrum. Here we only consider upper-level coupling case for the time-dependent spontaneous spectrum because in lower-level coupling case the system automatically evolved a pumping mechanism due to the coupling of ground level to the upper level via radiation field. Thus a steady-state limit exists in lower-level coupling scheme. \n \nWe investigate the phenomenon of atom localization by using the non stationary Autler-Townes microscopy. The decay rate T reduces the precision in position measurement which is consistent with the results of the non stationary spontaneous emission spectrum. This is due to the fact that for the upper-level coupling case, the standing wave field is coupled to atomic transition and it induces a coherence in the upper-level atomic transition but the spontaneous decay from the upper level to the intermediate level disturbs this coherence. When the effect of the spontaneous decay dominates the coherence effect the quantum interference phenomenon vanishes and thus the precision in localization reduces.

•Jan 1, 2000•0 citations

Localizing of a Four-Level Atom via Absorption Spectrum

Mostafa Sahrai, H Tajali

We propose a scheme for localizing an atom in a four-level configuration inside a classical standing wave field, conditioned upon the measurement of frequency of a weak probe field. In the classical standing wave field, the interaction between the atom and the field is position dependent due to the Rabi-frequency of the driving field. Hence, as the absorption frequency of the probe field is measured the position of the atom inside the classical standing wave field will be determined. Localizing of the atom via the absorption spectrum occurs during its motion in the standing wave field. The investigation of the probe field absorption shows that the degree of localization depends on the interaction parameters such as detuning, and Rabi-frequency of the driving field.

•Jan 1, 2006•0 citations

Subwavelength atom localization via amplitude and phase control of the absorption spectrum

Mostafa Sahrai, H. Tajalli, Kishore T. Kapale +1 more

We propose a scheme for subwavelength localization of an atom conditioned upon the absorption of a weak probe field at a particular frequency. Manipulating atom-field interaction on a certain transition by applying drive fields on nearby coupled transitions leads to interesting effects in the absorption spectrum of the weak probe field. We exploit this fact and employ a four-level system with three driving fields and a weak probe field, where one of the drive fields is a standing-wave field of a cavity. We show that the position of an atom along this standing wave is determined when probe-field absorption is measured. We find that absorption of the weak probe field at a certain frequency leads to subwavelength localization of the atom in either of the two half-wavelength regions of the cavity field by appropriate choice of the system parameters. We term this result as sub-half-wavelength localization to contrast it with the usual atom localization result of four peaks spread over one wavelength of the standing wave. We observe two localization peaks in either of the two half-wavelength regions along the cavity axis.

arXiv:quant-ph/0502158•Physical Review A•Jul 25, 2005•218 citations
We present a scheme for subwavelength single-atom localization that is based on the photon statistics measurement of the resonance fluorescence from the two-level atomic system. The photon number distribution of the resonance fluorescence depends on the position of the atom inside the standing-wave driving field via the position-dependent Rabi frequency. We show that this position-dependent Rabi frequency can be used to localize the atom within the subwavelength region.
We propose a scheme to localize a two-level atom inside a classical standing wave field conditioned upon the measurement of the frequency of a weak probe field at resonance excitation of a two-level atomic system. Inside the classical standing wave field, the interaction between the atom and the field is position-dependent due to the Rabi frequency of the driving field; hence, as the absorption frequency of the probe field is measured, the position of an atom inside the classical standing wave field will be determined. The effects of atomic parameters on atom localization are then discussed.
We propose a scheme to localize an atom in a three-level A-type configuration inside a classical standing wave field conditioned upon the measurement of frequency of a weak probe field. Inside the classical standing wave field, the interaction between atom and the field is position-dependent due to the Rabi frequency of the driving field; hence, as the absorption frequency of the probe field is measured, the position of an atom inside the classical standing wave field will be determined. Localizing of an atom via absorption spectrum occurs during its motion inside the standing wave field. An investigation of the probe field frequency shows that the degree of localization depends on interaction parameters such as detuning, phase difference between applied fields, and Rabi frequency of the driving field.
Entanglement of the atom and field leads towards the measurement of the state of the atom or field depending on the kind of measurement made. Taking advantage of this fact, we propose spectroscopic methods for the single atom localization within the subwavelength domain of the optical standing wave field. \n \nWhen a two-level atom interacts with some intense radiation field the spectrum of the scattered light signal exhibits a three-peak Mollow spectrum. We propose a scheme of atom localization based on the resonance fluorescence from a two-level atom interacting with a standing wave field. The Rabi frequency is considered to be position dependent and therefore, the spontaneously emitted photon carries the information about the center-of-mass motion of the atom. This leads to the localization of the single atom by measuring the frequency of the spontaneously emitted photon even during the passage of the atom through the standing wave field. We predict a spatial resolution in position information of up to λ/60 where λ is the optical wavelength. \n \nDetuning of the coherent field with the atomic transition plays an important role in the characterization of the peaks present in the Autler- Townes spectrum of a three-level atom. Strong line narrowing is observed in one of the peaks of the Autler- Townes doublet depending on the choice of the detuning. We investigate how this detuning effects the position information of the atom inside the standing wave field in upper-level and lower-level coupling schemes of Autler- Townes microscopy. We show an enhancement in precision position measurement by factor of at least 4 in upper-level coupling scheme due to the quantum interference phenomenon. This enhancement is not observed in lower-level coupling scheme where the quantum interference is not taking place. \n \nWe also consider a system where a three-level atom is interacting with a monochromatic radiation field in such a way that the decay takes place from upper level to the intermediate level with a rate T and from intermediate level to lower level at a rate γ. This type of system exhibits a non stationary scattered light signal. We report the results of the spontaneous emission spectrum for non stationary scattered light signal by using the definition of time-dependent physical spectrum. This is a rare example of problems where time-dependent physical spectrum can be calculated exactly. We study the characteristics of the spontaneous spectrum for a resonant and off-resonant case and show that this physical spectrum recovers the results of earlier work quite successfully. We also show that the decay rate r disturbs the atomic coherence and finally eliminates the dark line from the center of the spontaneous spectrum. Here we only consider upper-level coupling case for the time-dependent spontaneous spectrum because in lower-level coupling case the system automatically evolved a pumping mechanism due to the coupling of ground level to the upper level via radiation field. Thus a steady-state limit exists in lower-level coupling scheme. \n \nWe investigate the phenomenon of atom localization by using the non stationary Autler-Townes microscopy. The decay rate T reduces the precision in position measurement which is consistent with the results of the non stationary spontaneous emission spectrum. This is due to the fact that for the upper-level coupling case, the standing wave field is coupled to atomic transition and it induces a coherence in the upper-level atomic transition but the spontaneous decay from the upper level to the intermediate level disturbs this coherence. When the effect of the spontaneous decay dominates the coherence effect the quantum interference phenomenon vanishes and thus the precision in localization reduces.
We propose a scheme for localizing an atom in a four-level configuration inside a classical standing wave field, conditioned upon the measurement of frequency of a weak probe field. In the classical standing wave field, the interaction between the atom and the field is position dependent due to the Rabi-frequency of the driving field. Hence, as the absorption frequency of the probe field is measured the position of the atom inside the classical standing wave field will be determined. Localizing of the atom via the absorption spectrum occurs during its motion in the standing wave field. The investigation of the probe field absorption shows that the degree of localization depends on the interaction parameters such as detuning, and Rabi-frequency of the driving field.
We propose a scheme for subwavelength localization of an atom conditioned upon the absorption of a weak probe field at a particular frequency. Manipulating atom-field interaction on a certain transition by applying drive fields on nearby coupled transitions leads to interesting effects in the absorption spectrum of the weak probe field. We exploit this fact and employ a four-level system with three driving fields and a weak probe field, where one of the drive fields is a standing-wave field of a cavity. We show that the position of an atom along this standing wave is determined when probe-field absorption is measured. We find that absorption of the weak probe field at a certain frequency leads to subwavelength localization of the atom in either of the two half-wavelength regions of the cavity field by appropriate choice of the system parameters. We term this result as sub-half-wavelength localization to contrast it with the usual atom localization result of four peaks spread over one wavelength of the standing wave. We observe two localization peaks in either of the two half-wavelength regions along the cavity axis.