Squeezed states of light enable enhanced measurement precision by reducing noise below the standard quantum limit. A key application of squeezed light is nonlinear microscopy, where state-of-the-art performance is limited by photodamage and quantum-limited noise. Such microscopes require bright, pulsed light for optimal operation, yet generating and detecting bright pulsed squeezing at high levels remains challenging. In this work, we present an efficient technique to generate high levels of bright picosecond pulsed squeezed light using a
χ2 optical parametric amplification process in a waveguide. We measure
−3.2 dB of bright squeezing with optical power compatible with nonlinear microscopy, as well as
−3.6 dB of vacuum squeezing. Corrected for losses, these squeezing levels correspond to
−15.4−8.7+2.7 dB of squeezing generated in the waveguide. The measured level of bright amplitude pulsed squeezing is to our knowledge the highest reported to date, and will contribute to the broader adoption of quantum-enhanced nonlinear microscopy in biological studies.
Quantum-enhanced stimulated Raman scattering (QE-SRS) microscopy sits at the intersection of biomedical imaging, laser microscopy, and quantum optics toward realizing sensitive molecular-vibrational imaging. This Perspective explores the current status of this emerging field, integrating viewpoints from these diverse disciplines to highlight its potential for advancing biological and medical imaging. We discuss key challenges and future directions in leveraging quantum light to push the sensitivity limits of SRS microscopy, paving the way for next-generation imaging modalities.
Label-free optical microscopy through absorption or scattering spectroscopy provides fundamental insights across biology and materials science, yet its sensitivity remains fundamentally limited by photon shot noise. While recent demonstrations of quantum nonlinear microscopy show sub-shot-limited sensitivity, they are intrinsically limited by availability of high peak-power squeezed light sources. Here, we introduce squeezing-enhanced photothermal (SEPT) microscopy, a quantum imaging technique that leverages twin-beam quantum correlations to detect absorption induced signals with unprecedented sensitivity. SEPT achieves 3.5 dB noise suppression beyond the standard quantum limit, enabling a 2.5-fold increase in imaging throughput or 31% reduction in pump power, while providing an unmatched versatility through the intrinsic compatibility between continuous-wave squeezing and photothermal modulation. We showcase SEPT applications by providing high-precision characterization of nanoparticles and revealing subcellular structures, such as cytochrome c, that remain undetectable under shot-noise-limited imaging. By combining label-free contrast, quantum-enhanced sensitivity, and compatibility with existing microscopy platforms, SEPT establishes a new paradigm for molecular absorption imaging with far-reaching implications in cellular biology, nanoscience, and materials characterization.