Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Development of an atomic gravimeter based on atom interferometer

Taeg Yong Kwon, Sang-Bum Lee, Sang Eon Park, Myoung-Sun Heo, Hyun-Gue Hong, Chang Yong Park, Won-Kyu Lee, Dai-Hyuk Yu

Published Jun 10, 2015• 0 citations
OpenAlex

Related papers

Experimental progress in gravity measurement with an atom interferometer

Min-Kang Zhou, Zhong-Kun Hu, Xiao‐Chun Duan +3 more

物理学前沿:英文版•May 4, 2009•15 citations

Dependence of sensitivity of atom interferometer gravimeters on the Raman laser pulse sequences

Ren Li-Chun, Zhou Lin, Runbing Li +4 more

We investigate the dependence of the sensitivity of atom interferometer gravimeter on the Raman laser pulse sequence. The sensitivity of atom gravimeter can be adjusted by changing the pulse duration. Under the standard pulse configuration condition, the atom interferometer with four pulses is insensitive to the gravity if only gravity and its first order gradient are taken into account. The three-pulse Raman atom interferometer gravimeter displays best sensitivity. Atom interferometers with more than four Raman pulses show poorer sensitivity.

Acta Physica Sinica•Jan 1, 2009•4 citations

Atomic gravimeter robust to environmental effects

Cristian Daniel Panda, Matt Tao, Miguel Ceja +2 more

Atomic accelerometers and gravimeters are usually based on freely falling atoms in atomic fountains, which not only limits their size but also their robustness to environmental factors, such as tilts, magnetic fields, and vibrations. Such limitations have precluded their broad adoption in the field, for geophysics, geology, and inertial navigation. More recently, atom interferometers based on holding atoms in an optical lattice have been developed. Such gravimeters also suppress the influence of vibrations in the frequency range of ∼1 Hz and above by several orders of magnitude relative to conventional atomic gravimeters. Here, we show that such interferometers are robust to tilts of more than 8 mrad with respect to the vertical and can suppress the effect of even strong environmental magnetic fields and field gradients by using atoms in the F=3, 4 hyperfine ground states as co-magnetometers, potentially eliminating the need for shielding. We demonstrate gravimeter sensitivity of 0.7 mGal/Hz (1 mGal = 10 μm/s2) in a compact geometry where atoms only travel over millimeters of space.

arXiv:2305.05555•Applied Physics Letters•Aug 7, 2023•12 citations

Atom interferometers for precision gravity measurements

Torsten Gerrit Petelski

•Jan 1, 2005•12 citations

Atom interferometry and its applications for gravity sensing

Franck Pereira dos Santos, Luc Absil, Yann Balland +4 more

•Sep 20, 2021•0 citations

Progress Towards the Atom Interferometer Development

M. S. Aleynikov, G. V. Osipenko, A. V. Novoselov +1 more

Summary—Wide area of applications of geophysics, metrology and fundamental physics requires an atom interferometry technology, particularly an accurate measurement of the free fall acceleration parameter g. For today, atomic gravimeters based on matter wave interference have already reached the accuracy performance level of the best classical gravimeters [1]. Atomic gravimeters have an advantage over classical ones in terms of better sensitivity [2] and longer lifetime.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 12, 2025•0 citations
We investigate the dependence of the sensitivity of atom interferometer gravimeter on the Raman laser pulse sequence. The sensitivity of atom gravimeter can be adjusted by changing the pulse duration. Under the standard pulse configuration condition, the atom interferometer with four pulses is insensitive to the gravity if only gravity and its first order gradient are taken into account. The three-pulse Raman atom interferometer gravimeter displays best sensitivity. Atom interferometers with more than four Raman pulses show poorer sensitivity.
Atomic accelerometers and gravimeters are usually based on freely falling atoms in atomic fountains, which not only limits their size but also their robustness to environmental factors, such as tilts, magnetic fields, and vibrations. Such limitations have precluded their broad adoption in the field, for geophysics, geology, and inertial navigation. More recently, atom interferometers based on holding atoms in an optical lattice have been developed. Such gravimeters also suppress the influence of vibrations in the frequency range of ∼1 Hz and above by several orders of magnitude relative to conventional atomic gravimeters. Here, we show that such interferometers are robust to tilts of more than 8 mrad with respect to the vertical and can suppress the effect of even strong environmental magnetic fields and field gradients by using atoms in the F=3, 4 hyperfine ground states as co-magnetometers, potentially eliminating the need for shielding. We demonstrate gravimeter sensitivity of 0.7 mGal/Hz (1 mGal = 10 μm/s2) in a compact geometry where atoms only travel over millimeters of space.