Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Relaxation-oscilation-driven dc SQUIDs

Sergey A. Gudoshnikov, Vasili K. Semenov, Iu. V. Maslennikov, А. В. Васильев, Oleg V. Snigirev

Published Jan 1, 1989• 1 citation
OpenAlex

Related papers

Next generation dc-SQUIDs: relaxation oscillation SQUIDs

van Duuren, M.J., Derk Jan Adelerhof, G.C.S. Brons +3 more

•Dec 20, 1994•0 citations

Relaxation dc SQUIDs

Iu. V. Maslennikov, Oleg V. Snigirev

Technical Physics Letters•Nov 1, 1986•1 citation

Analysis of the Operation Modes of an RF-Field-Driven DC-SQUID

Yoshinao Mizugaki, Keiji Sugi

IEICE Transactions on Electronics•Jan 1, 2003•2 citations

Microwave oscillators based on dc SQUIDs

P. Bhupathi, M. P. DeFeo, Can‐Li Song +1 more

Bulletin of the American Physical Society•Mar 17, 2010•0 citations

Noise in relaxation-oscillation-driven DC SQUIDs

S.A. Gugoshnikov, O.V. Kaplunenko, Yu. V. Maslennikov +1 more

The noise properties of the simple relaxation-oscillation-driven DC SQUIDs (RO-SQUIDs) have been studied. A limitation of its internal energy sensitivity E/sub v/ at a level close to 4*10/sup -31/ J/Hz due to the influence of the Josephson junction plasma oscillation has been found for the 5- mu m-design-rule technology. The signal characteristics with the transfer flux-to-voltage factor up to 2 mV/ Phi /sub 0/ and equivalent noise flux of about 1.3*10/sup -6/ Phi /sub 0//Hz/sup 1/2/ in the new all-niobium version of the balanced RO-SQUID have been measured.

IEEE Transactions on Magnetics•Mar 1, 1991•10 citations

Second generation dc-SQUID sensors: relaxation oscillation SQUIDS (ROS) with frequency readout and double relaxation oscillation SQUIDS (DROS) with voltage readout

Derk Jan Adelerhof, Michiel van Duuren, Jaap Flokstra +1 more

Relaxation Oscillation SQUIDs (ROSs) based on 4x4 micrometers 2 Nb/AlOx Josephson tunnel junctions have been fabricated and characterized. A ROS consists of a hysteretic dc SQUID shunted by an inductor L and a resistor R in series to induce the relaxation oscillations. The values of L range from 20 nH up to about 300 nH, whereas the time constant L/R are between 8 and 45 ns. Frequency-flux characteristics have been recorded with the help of a spectrum analyzer, directly connected to the ROS. The relaxation frequencies range from 5 to 180 MHz. The experimental characteristics can be explained very well with a simple model describing the oscillation cycle. The effect of the self-induced magnetic field due to a magnetic coupling between the dc SQUID and the shunt circuit has been studied in detail. The sensitivity of ROSs and DROSs (Double Relaxation Oscillation SQUIDs) improves with increasing relaxation frequency. In (D)ROSs based on unshunted, hysteretic tunnel junction dc SQUIDs, the maximum relaxation frequency and the sensitivity are limited by LC resonances due to the SQUID capacitance and the shunt inductance. It is shown that the relaxation frequency can be increased up to frequencies of the order of 1 GHz if an extra resistor is integrated to damp these resonances. The optimum value of the damping resistor can be obtained from the ROS parameters. For stable operation of a (D)ROS, the shunt resistance should not be too large. The optimum value of this resistance can be calculated from the effective McCumber parameter and the bias current. Theoretically, the sensitivity of a ROS with a SQUID capacitance of 1 pF, a SQUID inductance of 20 pH and a relaxation frequency of 1 GHz equals about 5h, where h is Planck's constant. In a DROS with voltage readout based on similar SQUIDs, the theoretical sensitivity at a relaxation frequency of 1 GHz is 17h, with an estimated flux-to-voltage transfer coefficient of 5 mV/(phi) 0.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 2, 1994•6 citations
The noise properties of the simple relaxation-oscillation-driven DC SQUIDs (RO-SQUIDs) have been studied. A limitation of its internal energy sensitivity E/sub v/ at a level close to 4*10/sup -31/ J/Hz due to the influence of the Josephson junction plasma oscillation has been found for the 5- mu m-design-rule technology. The signal characteristics with the transfer flux-to-voltage factor up to 2 mV/ Phi /sub 0/ and equivalent noise flux of about 1.3*10/sup -6/ Phi /sub 0//Hz/sup 1/2/ in the new all-niobium version of the balanced RO-SQUID have been measured.
Relaxation Oscillation SQUIDs (ROSs) based on 4x4 micrometers 2 Nb/AlOx Josephson tunnel junctions have been fabricated and characterized. A ROS consists of a hysteretic dc SQUID shunted by an inductor L and a resistor R in series to induce the relaxation oscillations. The values of L range from 20 nH up to about 300 nH, whereas the time constant L/R are between 8 and 45 ns. Frequency-flux characteristics have been recorded with the help of a spectrum analyzer, directly connected to the ROS. The relaxation frequencies range from 5 to 180 MHz. The experimental characteristics can be explained very well with a simple model describing the oscillation cycle. The effect of the self-induced magnetic field due to a magnetic coupling between the dc SQUID and the shunt circuit has been studied in detail. The sensitivity of ROSs and DROSs (Double Relaxation Oscillation SQUIDs) improves with increasing relaxation frequency. In (D)ROSs based on unshunted, hysteretic tunnel junction dc SQUIDs, the maximum relaxation frequency and the sensitivity are limited by LC resonances due to the SQUID capacitance and the shunt inductance. It is shown that the relaxation frequency can be increased up to frequencies of the order of 1 GHz if an extra resistor is integrated to damp these resonances. The optimum value of the damping resistor can be obtained from the ROS parameters. For stable operation of a (D)ROS, the shunt resistance should not be too large. The optimum value of this resistance can be calculated from the effective McCumber parameter and the bias current. Theoretically, the sensitivity of a ROS with a SQUID capacitance of 1 pF, a SQUID inductance of 20 pH and a relaxation frequency of 1 GHz equals about 5h, where h is Planck's constant. In a DROS with voltage readout based on similar SQUIDs, the theoretical sensitivity at a relaxation frequency of 1 GHz is 17h, with an estimated flux-to-voltage transfer coefficient of 5 mV/(phi) 0.