Journal of the Optical Society of America B

Coherent control of the Goos–Hänchen shift via an inhomogeneous cavity

Qingli Jing, Chunguang Du, Fuchuan Lei, Ming Gao, Jiancun Gao

Published Jul 2, 2015• 9 citations
Publisher

Abstract

We investigate the reflected Goos–Hänchen shift of a probe light beam incident from the vacuum upon a metal–insulator–metal microcavity. The cavity is filled with three-level electromagnetically induced transparency atomic gas manipulated by a coherent coupling light field. It is found that the spatial distribution of the coupling field in the cavity structure should be taken into consideration, and as a consequence, the microcavity for the probe light is effectively an optically inhomogeneous cavity. This inhomogeneity can have a huge effect on the lateral shift of the probe light when the order of magnitude of the value of the real or imaginary part of the susceptibility of the probe light is not very small (about 10−4) and can lead to some detailed features that are absent in the homogeneous case.

DOI
10.1364/josab.32.001532

Related papers

Coherent control of the Goos-Hänchen shift

Ziauddin Ziauddin, Sajid Qamar, Muhammad Suhail Zubairy

The behavior of the Goos-H\"anchen (GH) shifts in the reflected and transmitted light beam which is incident on a cavity containing an intracavity medium of three-level or four-level atoms with electromagnetically induced transparency (EIT) is discussed. We report a coherent control of the GH shift in a fixed configuration or device via superluminal and subluminal wave propagation. For superluminal wave propagation, we observe negative GH shifts in the reflected part of the incident light whereas the shifts are positive in the transmitted light beam. This corresponds to the negative group index of the cavity in the former case and positive group index of the cavity in the latter. For subluminal wave propagation, the behavior of the GH shifts in the reflected light changes and positive shifts appear; however, the GH shifts in the transmitted light remains positive. The corresponding group index of the cavity is positive in both cases.

Physical Review A•Feb 22, 2010•153 citations

Control of the Goos-Hänchen shift of a light beam via a coherent driving field

Li‐Gang Wang, Manzoor Ikram, Muhammad Suhail Zubairy

We present a proposal to manipulate the Goos-H\"anchen shift of a light beam via a coherent control field, which is injected into a cavity configuration containing the two-level atomic medium. It is found that the lateral shifts of the reflected and transmitted probe beams can be easily controlled by adjusting the intensity and detuning of the control field. Using this scheme, the lateral shift at the fixed incident angle can be enhanced (positive or negative) under the suitable conditions on the control field, without changing the structure of the cavity.

arXiv:0709.3565•Physical Review A•Feb 11, 2008•180 citations

Vacuum-induced Goos-Hänchen shift

ZAREEN A. KHAN, Anwar Ali Khan, Zeeshan Ali +3 more

We present a theoretical investigation of the Goos-H\"anchen shift in an optical cavity containing a three-level atomic medium. Unlike conventional approaches that require external control or pump fields, transparency in our system is induced by the vacuum field itself through a phenomenon known as vacuum-induced transparency, distinguishing it from the traditional electromagnetically induced transparency. Inspired by this mechanism, we introduce the concept of the vacuum-induced Goos-H\"anchen (VIGH) shift, where the lateral displacement of the reflected beam is governed by vacuum field interactions. Additionally, we explore the influence of a microwave field on the atomic medium, demonstrating its ability to modulate both the magnitude and direction of the VIGH shift. Notably, we establish a tunable control over positive and negative VIGH shifts through the microwave field, with the shifts in magnitude further influenced by the photon number inside the cavity. Moreover, we examine the impact of Doppler broadening, revealing a unique deviation in VIGH shift behavior. In contrast to the Doppler-free case, where the microwave field can transition the VIGH shift between positive and negative regimes, Doppler broadening suppresses this transition, enhancing only the magnitude of the negative VIGH shift as microwave strength increases. Our findings provide deeper insights into light-matter interactions at the quantum level and open pathways for precision control of optical shifts in cavity-based quantum systems.

Physical Review A•Jul 21, 2025•9 citations

Coherent Control of the Goos-Hänchen Shift in a Cavity Containing a Five-Level Double-Ladder Atomic System

Changyou Luo, Yongqiang Kang, Xiaoyu Dai +1 more

In this paper, we proposed a cavity containing an intracavity medium of five-level double-ladder-type atoms with electromagnetically induced transparency to enhance Goos-Hänchen shifts of reflected and transmitted light beams. The dependence of the Goos-Hänchen shifts has been analyzed. It is shown that Goos-Hänchen shifts can be controlled by modifying the intensity and detuning of the coherent control field without changing material and the structure of the dielectric interface. This work has considerable potential for applications such as optical devices in information processing, flexible optical-beam steering and alignment, optical sensors and optical switches.

IEEE photonics journal•Oct 23, 2023•1 citation

Control of the Goos–Hänchen shifts of a probe light beam using phase tunability of the intracavity medium

Arash Radmehr, Mostafa Sahrai, Hamed Sattari

This paper presents the Goos-Hänchen (GH) shifts of a probe light beam in a fixed cavity configuration containing the three level V-type atomic medium. We found that in the presence of decay-induced interference, the lateral shifts of both the reflected and transmitted probe light beam can easily be controlled just by the relative phase of applied fields. We also discuss the intensity of the applied field on GH shifts of the reflected and transmitted probe light beam.

Applied Optics•Mar 8, 2016•8 citations

Giant Goos–Hänchen shift via spontaneous generated coherence

Ziauddin Ziauddin

The influence of spontaneous generated coherence (SGC) on the Goos–Hänchen (GH) shift in the reflected light is presented. A weak probe light is incident on a cavity containing three-level gaseous atomic medium consist of 85Rb atoms. The atom–field interaction follows electromagnetically induced transparency configuration, and the SGC modifies the dispersion and absorption properties of a system [Y. Niu and S. Gong, Phys. Rev. A 73, 053811 (2006)]. The SGC enhances the Kerr nonlinearity which leads to giant negative and positive GH shifts in the reflected light. Further, the control of negative and positive GH shifts is achieved via manipulation of probe field detuning.

Journal of Modern Optics•Jul 10, 2015•24 citations
We investigate the reflected Goos–Hänchen shift of a probe light beam incident from the vacuum upon a metal–insulator–metal microcavity. The cavity is filled with three-level electromagnetically induced transparency atomic gas manipulated by a coherent coupling light field. It is found that the spatial distribution of the coupling field in the cavity structure should be taken into consideration, and as a consequence, the microcavity for the probe light is effectively an optically inhomogeneous cavity. This inhomogeneity can have a huge effect on the lateral shift of the probe light when the order of magnitude of the value of the real or imaginary part of the susceptibility of the probe light is not very small (about 10−4) and can lead to some detailed features that are absent in the homogeneous case.
The behavior of the Goos-H\"anchen (GH) shifts in the reflected and transmitted light beam which is incident on a cavity containing an intracavity medium of three-level or four-level atoms with electromagnetically induced transparency (EIT) is discussed. We report a coherent control of the GH shift in a fixed configuration or device via superluminal and subluminal wave propagation. For superluminal wave propagation, we observe negative GH shifts in the reflected part of the incident light whereas the shifts are positive in the transmitted light beam. This corresponds to the negative group index of the cavity in the former case and positive group index of the cavity in the latter. For subluminal wave propagation, the behavior of the GH shifts in the reflected light changes and positive shifts appear; however, the GH shifts in the transmitted light remains positive. The corresponding group index of the cavity is positive in both cases.
We present a proposal to manipulate the Goos-H\"anchen shift of a light beam via a coherent control field, which is injected into a cavity configuration containing the two-level atomic medium. It is found that the lateral shifts of the reflected and transmitted probe beams can be easily controlled by adjusting the intensity and detuning of the control field. Using this scheme, the lateral shift at the fixed incident angle can be enhanced (positive or negative) under the suitable conditions on the control field, without changing the structure of the cavity.
We present a theoretical investigation of the Goos-H\"anchen shift in an optical cavity containing a three-level atomic medium. Unlike conventional approaches that require external control or pump fields, transparency in our system is induced by the vacuum field itself through a phenomenon known as vacuum-induced transparency, distinguishing it from the traditional electromagnetically induced transparency. Inspired by this mechanism, we introduce the concept of the vacuum-induced Goos-H\"anchen (VIGH) shift, where the lateral displacement of the reflected beam is governed by vacuum field interactions. Additionally, we explore the influence of a microwave field on the atomic medium, demonstrating its ability to modulate both the magnitude and direction of the VIGH shift. Notably, we establish a tunable control over positive and negative VIGH shifts through the microwave field, with the shifts in magnitude further influenced by the photon number inside the cavity. Moreover, we examine the impact of Doppler broadening, revealing a unique deviation in VIGH shift behavior. In contrast to the Doppler-free case, where the microwave field can transition the VIGH shift between positive and negative regimes, Doppler broadening suppresses this transition, enhancing only the magnitude of the negative VIGH shift as microwave strength increases. Our findings provide deeper insights into light-matter interactions at the quantum level and open pathways for precision control of optical shifts in cavity-based quantum systems.
In this paper, we proposed a cavity containing an intracavity medium of five-level double-ladder-type atoms with electromagnetically induced transparency to enhance Goos-Hänchen shifts of reflected and transmitted light beams. The dependence of the Goos-Hänchen shifts has been analyzed. It is shown that Goos-Hänchen shifts can be controlled by modifying the intensity and detuning of the coherent control field without changing material and the structure of the dielectric interface. This work has considerable potential for applications such as optical devices in information processing, flexible optical-beam steering and alignment, optical sensors and optical switches.
The influence of spontaneous generated coherence (SGC) on the Goos–Hänchen (GH) shift in the reflected light is presented. A weak probe light is incident on a cavity containing three-level gaseous atomic medium consist of 85Rb atoms. The atom–field interaction follows electromagnetically induced transparency configuration, and the SGC modifies the dispersion and absorption properties of a system [Y. Niu and S. Gong, Phys. Rev. A 73, 053811 (2006)]. The SGC enhances the Kerr nonlinearity which leads to giant negative and positive GH shifts in the reflected light. Further, the control of negative and positive GH shifts is achieved via manipulation of probe field detuning.