Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

With Vibrationally Excited Thiophosgene Molecule and Double-Well Ion Traps

Dmytro Shyshlov

Published Jan 1, 2015• 0 citations
OpenAlex

Abstract

For practical realization of quantum information processing we need a quantum system that provides reliable preparation of the initial state, high-fidelity quantum gate operations, error tolerance, readout of the result of quantum computation and scalability of the system to increase the number of qubits. In this dissertation we show how these requirements can be addressed for molecular quantum computer. For computational study of quantum information processing with molecules we employ thiophosgene (SCCl2) molecule that has been used as a test system for quantum control experiments [Mol. Phys. 105, 1999 (2007)]. We investigate the gateway scheme of control in which transitions between the vibrational states that encode qubits are only allowed through the intermediate “gateway” state in the B electronic state. This scheme of control provides reliable preparation of the initial qubit state and allows using UV/vis laser pulses. We demonstrate that high-fidelity quantum gates are possible to achieve in molecular quantum computer. The optimal control theory is employed to obtain a shape of laser pulse that performs CNOT gate with ~0.9999 fidelity. Analysis of frequency profile of the optimal pulse shows that preparation of the high-fidelity computational pulse requires only 64 frequency channels. Error tolerance of the computational pulse is studied by modifying amplitudes and phases of frequency components. It is shown that gate fidelity remains high after small modifications are introduced to the optimal pulse. The scheme of readout of quantum information using quantum beat spectroscopy is proposed. The quantum beat signal is obtained from excitation of the final superposition of the qubit states to a readout state in the B electronic state with a time-delayed pulse. We find that fitting the quantum beat signal with a standard fitting expression produces a phase error and propose a new accurate expression that includes phase correction term. The system of two atomic ions trapped in a double-well potential is also studied as a first step towards scalable quantum computation with trapped molecular ions. The rigorous computational treatment of the system provides explanation of the vibrational energy transfer between the ions in terms of wave packet dynamics in the accurate asymmetric potential.

Related papers

On readout of vibrational qubits using quantum beats

Dmytro Shyshlov, Eduardo Berrios, Martin Gruebele +1 more

Readout of the final states of qubits is a crucial step towards implementing quantum computation in experiment. Although not scalable to large numbers of qubits per molecule, computational studies show that molecular vibrations could provide a significant (factor 2-5 in the literature) increase in the number of qubits compared to two-level systems. In this theoretical work, we explore the process of readout from vibrational qubits in thiophosgene molecule, SCCl2, using quantum beat oscillations. The quantum beats are measured by first exciting the superposition of the qubit-encoding vibrational states to the electronically excited readout state with variable time-delay pulses. The resulting oscillation of population of the readout state is then detected as a function of time delay. In principle, fitting the quantum beat signal by an analytical expression should allow extracting the values of probability amplitudes and the relative phases of the vibrational qubit states. However, we found that if this procedure is implemented using the standard analytic expression for quantum beats, a non-negligible phase error is obtained. We discuss the origin and properties of this phase error, and propose a new analytical expression to correct the phase error. The corrected expression fits the quantum beat signal very accurately, which may permit reading out the final state of vibrational qubits in experiments by combining the analytic fitting expression with numerical modelling of the readout process. The new expression is also useful as a simple model for fitting any quantum beat experiments where more accurate phase information is desired.

The Journal of Chemical Physics•Dec 9, 2014•8 citations

Quantum computation with vibrationally excited polyatomic molecules: effects of rotation, level structure, and field gradients

Daniel Weidinger, Martin Gruebele

Accurate rotation–vibration energy levels and transition dipoles of the molecule thiophosgene are used to model the execution of quantum gates with shaped laser pulses. Qubits are encoded in 2 n vibrational computing states on the ground electronic surface of the molecule. Computations are carried out by cycling amplitude between these computing states and a gateway state with a shaped laser pulse. The shaped pulse that performs the computation is represented by a physical model of a 128–1024 channel pulse shaper. Pulse shapes are optimized with a standard genetic algorithm, yielding experimentally realizable computing pulses. The robustness of optimization is studied as a function of the vibrational states selected, rotational level structure, additional vibrational levels not assigned to the computation, and compensation for laser power variation across a molecular ensemble.

Molecular Physics•Jul 10, 2007•38 citations

High Fidelity Quantum Gates with Vibrational Qubits

Eduardo Berríos, Martin Gruebele, Dmytro Shyshlov +2 more

Physical implementation of quantum gates acting on qubits does not achieve a perfect fidelity of 1. The actual output qubit may not match the targeted output of the desired gate. According to theoretical estimates, intrinsic gate fidelities >99.99% are necessary so that error correction codes can be used to achieve perfect fidelity. Here we test what fidelity can be accomplished for a CNOT gate executed by a shaped ultrafast laser pulse interacting with vibrational states of the molecule SCCl(2). This molecule has been used as a test system for low-fidelity calculations before. To make our test more stringent, we include vibrational levels that do not encode the desired qubits but are close enough in energy to interfere with population transfer by the laser pulse. We use two complementary approaches: optimal control theory determines what the best possible pulse can do; a more constrained physical model calculates what an experiment likely can do. Optimal control theory finds pulses with fidelity >0.9999, in excess of the quantum error correction threshold with 8 × 10(4) iterations. On the other hand, the physical model achieves only 0.9992 after 8 × 10(4) iterations. Both calculations converge as an inverse power law toward unit fidelity after >10(2) iterations/generations. In principle, the fidelities necessary for quantum error correction are reachable with qubits encoded by molecular vibrations. In practice, it will be challenging with current laboratory instrumentation because of slow convergence past fidelities of 0.99.

The Journal of Physical Chemistry A•Jul 18, 2012•15 citations

Complexity and simplicity of optimal control theory pulses shaped for controlling vibrational qubits

Dmytro Shyshlov, Dmitri Babikov

In the context of molecular quantum computation the optimal control theory (OCT) is used to obtain shaped laser pulses for high-fidelity control of vibrational qubits. Optimization is done in time domain and the OCT algorithm varies values of electric field in each time step independently, tuning hundreds of thousands of parameters to find one optimal solution. Such flexibility is not available in experiments, where pulse shaping is done in frequency domain and the number of "tuning knobs" is much smaller. The question of possible experimental interpretations of theoretically found OCT solutions arises. In this work we analyze very accurate optimal pulse that we obtained for implementing quantum gate CNOT for the two-qubit system encoded into the exited vibrational states of thiophosgene molecule. Next, we try to alter this pulse by reducing the number of available frequency channels and intentionally introducing systematic and random errors (in frequency domain, by modifying the values of amplitudes and phases of different frequency components). We conclude that a very limited number of frequency components (only 32 in the model of thiophosgene) are really necessary for accurate control of the vibrational two-qubit system, and such pulses can be readily constructed using OCT. If the amplitude and phase errors of different frequency components do not exceed ±3% of the optimal values, one can still achieve accurate transformations of the vibrational two-qubit system, with gate fidelity of CNOT exceeding 0.99.

The Journal of Chemical Physics•Nov 21, 2012•7 citations

Computational study of vibrational qubits in anharmonic linear ion traps

Lei Wang

A string of cold ions confined in a linear trap represents a man-made quantum object with a broad range of applications in atomic and molecular spectroscopy, such as high-precision measurement of atomic properties. An efficient isolation from the environment guarantees excellent coherent properties of such systems and makes them suitable for practical realization of the quantum information processing. The pioneering theoretical [Cirac and Zoller] and experimental [Wineland and Monroe] work in 1990s resulted in the explosive expansion of this field during the last decade. In this dissertation an alternative new method for controlling the quantized motional/vibrational states of ions in a trap is explored theoretically. It is proposed to create small anharmonicity in the trapping potential which would modify the spectrum of states and allow addressing the state-to-state transitions selectively. In this approach all ions remain in the ground electronic state and their motion is controlled adiabatically and coherently by applying the optimally shaped electric fields (RF). The optimal control theory, accurate numerical calculation of the energies and wavefunctions, and numerical propagation of wave packets are employed. Two sources of vibrational anharmonicity are studied: the intrinsic Coulomb anharmonicity due to the ion-ion interactions and the external anharmonicity of the trapping potential. It is shown that the magnitude of Coulomb anharmonicity is insufficient for the control. In contrast, anharmonicity of the trapping potential allows controlling the motion of ions very accurately. It is demonstrated that one ion in a slightly anharmonic trap can be easily controlled and used to represent one qubit. A multi-qubit system can be created by employing a long progression of states of a single ion, or by trapping multiple ions and controlling several normal vibration modes of the ion string. Up to four qubits are modeled in this work and accurate pulses are optimized for a set of universal quantum gates: NOT, conditional NOT (CNOT) and Hadamard transformation. The control field for Shor's algorithm (quantum algorithm for factorization onto prime numbers) is also obtained. It is demonstrated that a careful choice of system properties allows achieving very high accuracy of qubit transformations, up to 0.999.

•Jan 1, 2012•0 citations

Anharmonic Properties of the Vibrational Two-Qubit System

Yingying Gu

My thesis focuses on theoretical studies in the molecular quantum computing with vibrational qubits. We studied how the molecular vibrational properties affect the fidelity of the logic gates. Our approach is to encode states of the quantum information register into the vibrational eigenstates of a molecule and use the shaped laser pulse (femtosecond, infrared) to control the vibrational state-to-state transition. By using the Optimal Control Theory to shape a femtosecond laser and numerical propagation of laser-driven vibrational wave packets, we analyzed how the vibrational properties of a two-qubit system affect the accuracy of the quantum gates and how to effectively control the vibrational state-to-state transitions. From these studies, we found the anharmonicities are very important for the control of the vibrational state-to-state transitions and an intricate interplay between the frequencies and anharmonicities in the two-qubit system leads to the occurrence of resonances between different transitions in the vibrational manifold. Such resonances cause "leakage" of population into other vibrational states and hinder the control. From theoretical analysis of resonances, we formulate several criteria for selection of molecule for implementation of the vibrational two-qubit system. These criteria can help experimentalists to choose the best molecules to achieve accurate qubit transformations in the experiment.

•Feb 11, 2015•0 citations
For practical realization of quantum information processing we need a quantum system that provides reliable preparation of the initial state, high-fidelity quantum gate operations, error tolerance, readout of the result of quantum computation and scalability of the system to increase the number of qubits. In this dissertation we show how these requirements can be addressed for molecular quantum computer. For computational study of quantum information processing with molecules we employ thiophosgene (SCCl2) molecule that has been used as a test system for quantum control experiments [Mol. Phys. 105, 1999 (2007)]. We investigate the gateway scheme of control in which transitions between the vibrational states that encode qubits are only allowed through the intermediate “gateway” state in the B electronic state. This scheme of control provides reliable preparation of the initial qubit state and allows using UV/vis laser pulses. We demonstrate that high-fidelity quantum gates are possible to achieve in molecular quantum computer. The optimal control theory is employed to obtain a shape of laser pulse that performs CNOT gate with ~0.9999 fidelity. Analysis of frequency profile of the optimal pulse shows that preparation of the high-fidelity computational pulse requires only 64 frequency channels. Error tolerance of the computational pulse is studied by modifying amplitudes and phases of frequency components. It is shown that gate fidelity remains high after small modifications are introduced to the optimal pulse. The scheme of readout of quantum information using quantum beat spectroscopy is proposed. The quantum beat signal is obtained from excitation of the final superposition of the qubit states to a readout state in the B electronic state with a time-delayed pulse. We find that fitting the quantum beat signal with a standard fitting expression produces a phase error and propose a new accurate expression that includes phase correction term. The system of two atomic ions trapped in a double-well potential is also studied as a first step towards scalable quantum computation with trapped molecular ions. The rigorous computational treatment of the system provides explanation of the vibrational energy transfer between the ions in terms of wave packet dynamics in the accurate asymmetric potential.
Readout of the final states of qubits is a crucial step towards implementing quantum computation in experiment. Although not scalable to large numbers of qubits per molecule, computational studies show that molecular vibrations could provide a significant (factor 2-5 in the literature) increase in the number of qubits compared to two-level systems. In this theoretical work, we explore the process of readout from vibrational qubits in thiophosgene molecule, SCCl2, using quantum beat oscillations. The quantum beats are measured by first exciting the superposition of the qubit-encoding vibrational states to the electronically excited readout state with variable time-delay pulses. The resulting oscillation of population of the readout state is then detected as a function of time delay. In principle, fitting the quantum beat signal by an analytical expression should allow extracting the values of probability amplitudes and the relative phases of the vibrational qubit states. However, we found that if this procedure is implemented using the standard analytic expression for quantum beats, a non-negligible phase error is obtained. We discuss the origin and properties of this phase error, and propose a new analytical expression to correct the phase error. The corrected expression fits the quantum beat signal very accurately, which may permit reading out the final state of vibrational qubits in experiments by combining the analytic fitting expression with numerical modelling of the readout process. The new expression is also useful as a simple model for fitting any quantum beat experiments where more accurate phase information is desired.
Accurate rotation–vibration energy levels and transition dipoles of the molecule thiophosgene are used to model the execution of quantum gates with shaped laser pulses. Qubits are encoded in 2 n vibrational computing states on the ground electronic surface of the molecule. Computations are carried out by cycling amplitude between these computing states and a gateway state with a shaped laser pulse. The shaped pulse that performs the computation is represented by a physical model of a 128–1024 channel pulse shaper. Pulse shapes are optimized with a standard genetic algorithm, yielding experimentally realizable computing pulses. The robustness of optimization is studied as a function of the vibrational states selected, rotational level structure, additional vibrational levels not assigned to the computation, and compensation for laser power variation across a molecular ensemble.
Physical implementation of quantum gates acting on qubits does not achieve a perfect fidelity of 1. The actual output qubit may not match the targeted output of the desired gate. According to theoretical estimates, intrinsic gate fidelities >99.99% are necessary so that error correction codes can be used to achieve perfect fidelity. Here we test what fidelity can be accomplished for a CNOT gate executed by a shaped ultrafast laser pulse interacting with vibrational states of the molecule SCCl(2). This molecule has been used as a test system for low-fidelity calculations before. To make our test more stringent, we include vibrational levels that do not encode the desired qubits but are close enough in energy to interfere with population transfer by the laser pulse. We use two complementary approaches: optimal control theory determines what the best possible pulse can do; a more constrained physical model calculates what an experiment likely can do. Optimal control theory finds pulses with fidelity >0.9999, in excess of the quantum error correction threshold with 8 × 10(4) iterations. On the other hand, the physical model achieves only 0.9992 after 8 × 10(4) iterations. Both calculations converge as an inverse power law toward unit fidelity after >10(2) iterations/generations. In principle, the fidelities necessary for quantum error correction are reachable with qubits encoded by molecular vibrations. In practice, it will be challenging with current laboratory instrumentation because of slow convergence past fidelities of 0.99.
In the context of molecular quantum computation the optimal control theory (OCT) is used to obtain shaped laser pulses for high-fidelity control of vibrational qubits. Optimization is done in time domain and the OCT algorithm varies values of electric field in each time step independently, tuning hundreds of thousands of parameters to find one optimal solution. Such flexibility is not available in experiments, where pulse shaping is done in frequency domain and the number of "tuning knobs" is much smaller. The question of possible experimental interpretations of theoretically found OCT solutions arises. In this work we analyze very accurate optimal pulse that we obtained for implementing quantum gate CNOT for the two-qubit system encoded into the exited vibrational states of thiophosgene molecule. Next, we try to alter this pulse by reducing the number of available frequency channels and intentionally introducing systematic and random errors (in frequency domain, by modifying the values of amplitudes and phases of different frequency components). We conclude that a very limited number of frequency components (only 32 in the model of thiophosgene) are really necessary for accurate control of the vibrational two-qubit system, and such pulses can be readily constructed using OCT. If the amplitude and phase errors of different frequency components do not exceed ±3% of the optimal values, one can still achieve accurate transformations of the vibrational two-qubit system, with gate fidelity of CNOT exceeding 0.99.
A string of cold ions confined in a linear trap represents a man-made quantum object with a broad range of applications in atomic and molecular spectroscopy, such as high-precision measurement of atomic properties. An efficient isolation from the environment guarantees excellent coherent properties of such systems and makes them suitable for practical realization of the quantum information processing. The pioneering theoretical [Cirac and Zoller] and experimental [Wineland and Monroe] work in 1990s resulted in the explosive expansion of this field during the last decade. In this dissertation an alternative new method for controlling the quantized motional/vibrational states of ions in a trap is explored theoretically. It is proposed to create small anharmonicity in the trapping potential which would modify the spectrum of states and allow addressing the state-to-state transitions selectively. In this approach all ions remain in the ground electronic state and their motion is controlled adiabatically and coherently by applying the optimally shaped electric fields (RF). The optimal control theory, accurate numerical calculation of the energies and wavefunctions, and numerical propagation of wave packets are employed. Two sources of vibrational anharmonicity are studied: the intrinsic Coulomb anharmonicity due to the ion-ion interactions and the external anharmonicity of the trapping potential. It is shown that the magnitude of Coulomb anharmonicity is insufficient for the control. In contrast, anharmonicity of the trapping potential allows controlling the motion of ions very accurately. It is demonstrated that one ion in a slightly anharmonic trap can be easily controlled and used to represent one qubit. A multi-qubit system can be created by employing a long progression of states of a single ion, or by trapping multiple ions and controlling several normal vibration modes of the ion string. Up to four qubits are modeled in this work and accurate pulses are optimized for a set of universal quantum gates: NOT, conditional NOT (CNOT) and Hadamard transformation. The control field for Shor's algorithm (quantum algorithm for factorization onto prime numbers) is also obtained. It is demonstrated that a careful choice of system properties allows achieving very high accuracy of qubit transformations, up to 0.999.
My thesis focuses on theoretical studies in the molecular quantum computing with vibrational qubits. We studied how the molecular vibrational properties affect the fidelity of the logic gates. Our approach is to encode states of the quantum information register into the vibrational eigenstates of a molecule and use the shaped laser pulse (femtosecond, infrared) to control the vibrational state-to-state transition. By using the Optimal Control Theory to shape a femtosecond laser and numerical propagation of laser-driven vibrational wave packets, we analyzed how the vibrational properties of a two-qubit system affect the accuracy of the quantum gates and how to effectively control the vibrational state-to-state transitions. From these studies, we found the anharmonicities are very important for the control of the vibrational state-to-state transitions and an intricate interplay between the frequencies and anharmonicities in the two-qubit system leads to the occurrence of resonances between different transitions in the vibrational manifold. Such resonances cause "leakage" of population into other vibrational states and hinder the control. From theoretical analysis of resonances, we formulate several criteria for selection of molecule for implementation of the vibrational two-qubit system. These criteria can help experimentalists to choose the best molecules to achieve accurate qubit transformations in the experiment.