Bulletin of the American Physical Society

Two dimensional analysis of a free oscillation atom interferometer

Rudra Kafle, Alex A. Zozulya

Published Feb 28, 2012• 0 citations
OpenAlex

Related papers

Theoretical analysis of a free oscillation atom interferometer in a weakly confining magnetic trap

Rudra Kafle, Dana Anderson, Alex A. Zozulya

Bulletin of the American Physical Society•May 28, 2010•0 citations

Achieving long interaction times with a free-oscillation atom interferometer

Adam Fallon, Robert H. Leonard, R. A. Horne +2 more

Bulletin of the American Physical Society•Jun 6, 2013•0 citations

Closure of an atom interferometer with a nearby oscillating pendulum

Michael Manicchia, Jens Berdahl, Takaho Tsubakiyama +1 more

The European Physical Journal Special Topics•Dec 4, 2025•2 citations

Analysis of a free oscillation atom interferometer

Rudra Kafle, Dana Z. Anderson, Alex A. Zozulya

We analyze a Bose-Einstein condensate (BEC)-based free oscillation atom Michelson interferometer in a weakly confining harmonic magnetic trap. A BEC at the center of the trap is split into two harmonics by a laser standing wave. The harmonics move in opposite directions with equal speeds and turn back under the influence of the trapping potential at their classical turning points. The harmonics are allowed to pass through each other and a recombination pulse is applied when they overlap at the end of a cycle after they return for the second time. We derive an expression for the contrast of the interferometric fringes and obtain the fundamental limit of performance of the interferometer in the parameter space.

arXiv:1012.4380•Physical Review A•Sep 27, 2011•12 citations

Contribution to the theory of atom interferometers

Charles Antoine, Christian Bordé

•Jan 1, 2004•0 citations

Confinement effects in a guided-wave atom interferometer with millimeter-scale arm separation

John H. Burke, Benjamin Deissler, K. J. Hughes +1 more

Guided-wave atom interferometers measure interference effects using atoms held in a confining potential. In one common implementation, the confinement is primarily two dimensional, and the atoms move along the nearly free dimension after being manipulated by an off-resonant standing wave laser beam. In this configuration, residual confinement along the nominally free axis can introduce a phase gradient to the atoms that limits the arm separation of the interferometer. We experimentally investigate this effect in detail, and show that it can be alleviated by having the atoms undergo a more symmetric motion in the guide. This can be achieved by either using additional laser pulses or by allowing the atoms to freely oscillate in the potential. With these techniques, we demonstrate interferometer measurement times up to $72\phantom{\rule{0.3em}{0ex}}\mathrm{ms}$ and arm separations up to $0.42\phantom{\rule{0.3em}{0ex}}\mathrm{mm}$ with a well controlled phase, or times of $0.91\phantom{\rule{0.3em}{0ex}}\mathrm{s}$ and separations of $1.7\phantom{\rule{0.3em}{0ex}}\mathrm{mm}$ with an uncontrolled phase.

arXiv:0710.1081•Physical Review A•Aug 14, 2008•48 citations
We analyze a Bose-Einstein condensate (BEC)-based free oscillation atom Michelson interferometer in a weakly confining harmonic magnetic trap. A BEC at the center of the trap is split into two harmonics by a laser standing wave. The harmonics move in opposite directions with equal speeds and turn back under the influence of the trapping potential at their classical turning points. The harmonics are allowed to pass through each other and a recombination pulse is applied when they overlap at the end of a cycle after they return for the second time. We derive an expression for the contrast of the interferometric fringes and obtain the fundamental limit of performance of the interferometer in the parameter space.
Guided-wave atom interferometers measure interference effects using atoms held in a confining potential. In one common implementation, the confinement is primarily two dimensional, and the atoms move along the nearly free dimension after being manipulated by an off-resonant standing wave laser beam. In this configuration, residual confinement along the nominally free axis can introduce a phase gradient to the atoms that limits the arm separation of the interferometer. We experimentally investigate this effect in detail, and show that it can be alleviated by having the atoms undergo a more symmetric motion in the guide. This can be achieved by either using additional laser pulses or by allowing the atoms to freely oscillate in the potential. With these techniques, we demonstrate interferometer measurement times up to 72ms72\phantom{\rule{0.3em}{0ex}}\mathrm{ms}72ms and arm separations up to 0.42mm0.42\phantom{\rule{0.3em}{0ex}}\mathrm{mm}0.42mm with a well controlled phase, or times of 0.91s0.91\phantom{\rule{0.3em}{0ex}}\mathrm{s}0.91s and separations of 1.7mm1.7\phantom{\rule{0.3em}{0ex}}\mathrm{mm}1.7mm with an uncontrolled phase.