Bulletin of the American Physical Society

Superconducting Qubit Readout Using Capture-Disperse-Release of Microwave Field

Eric Mlinar

Published Mar 19, 2013• 0 citations
OpenAlex

Related papers

A new microwave resonator readout scheme for superconducting qubits

Michael Metcalfe

•Jan 1, 2008•2 citations

Catch-Disperse-Release Readout for Superconducting Qubits

Eyob Alebachew Sete, Andrei Galiautdinov, Eric Mlinar +2 more

We analyze a single-shot readout for superconducting qubits via the controlled catch, dispersion, and release of a microwave field. A tunable coupler is used to decouple the microwave resonator from the transmission line during the dispersive qubit-resonator interaction, thus circumventing damping from the Purcell effect. We show that, if the qubit frequency tuning is sufficiently adiabatic, a fast high-fidelity qubit readout is possible, even in the strongly nonlinear dispersive regime. Interestingly, the Jaynes-Cummings nonlinearity leads to the quadrature squeezing of the resonator field below the standard quantum limit, resulting in a significant decrease of the measurement error.

arXiv:1302.7020•Physical Review Letters•May 22, 2013•31 citations

Novel microwave readout for phase qubits

Shwetank Kumar, Matthias Steffen, Mary-Beth Rothwell +3 more

Bulletin of the American Physical Society•Mar 17, 2010•0 citations

Sequential Dispersive Measurement of a Superconducting Qubit

Théau Peronnin, Danijela Marković, Quentin Ficheux +1 more

We present a superconducting device that realizes the sequential measurement of a transmon qubit. The device disables common limitations of dispersive readout such as Purcell effect or transients in the cavity mode by turning on and off the coupling to the measurement channel on demand. The qubit measurement begins by loading a readout resonator that is coupled to the qubit. After an optimal interaction time with negligible loss, a microwave pump releases the content of the readout mode by upconversion into a measurement line in a characteristic time as low as 10 ns, which is 400 times shorter than the lifetime of the readout resonator. A direct measurement of the released field quadratures demonstrates a readout fidelity of 97.5% in a total measurement time of 220 ns. The Wigner tomography of the readout mode allows us to characterize the non-Gaussian nature of the readout mode and its dynamics.

arXiv:1904.04635•Physical Review Letters•May 7, 2020•17 citations

Millimeter Wave Readout of a Superconducting Qubit

Akash V. Dixit, Zachary Parrott, Dennis Chunikhin +3 more

Physical Review Letters•Sep 3, 2026•1 citation

Sequential measurement of a superconducting qubit

Théau Peronnin, Danijela Marković, Quentin Ficheux +1 more

We present a superconducting device that realizes the sequential measurement of a transmon qubit. The unitary evolution between system and probe is indeed separated in time and space from the measurement of the probe itself. The device disables common limitations of dispersive readout such as Purcell effect or transients in the cavity mode by tuning the coupling to the measurement channel on demand. The probe is initially stored in a memory mode and coupled to the qubit until a microwave pump releases it into an output line in a characteristic time as low as $10~\mathrm{ns}$, which is 400 times shorter than the memory lifetime. The Wigner function of the memory allows us to characterize the non-Gaussian nature of the probe and its dynamics. A direct measurement of the released probe field quadratures demonstrates a readout fidelity of $97.5~\%$ in a total measurement time of $220~\mathrm{ns}$.

•Apr 9, 2019•2 citations
We analyze a single-shot readout for superconducting qubits via the controlled catch, dispersion, and release of a microwave field. A tunable coupler is used to decouple the microwave resonator from the transmission line during the dispersive qubit-resonator interaction, thus circumventing damping from the Purcell effect. We show that, if the qubit frequency tuning is sufficiently adiabatic, a fast high-fidelity qubit readout is possible, even in the strongly nonlinear dispersive regime. Interestingly, the Jaynes-Cummings nonlinearity leads to the quadrature squeezing of the resonator field below the standard quantum limit, resulting in a significant decrease of the measurement error.
We present a superconducting device that realizes the sequential measurement of a transmon qubit. The device disables common limitations of dispersive readout such as Purcell effect or transients in the cavity mode by turning on and off the coupling to the measurement channel on demand. The qubit measurement begins by loading a readout resonator that is coupled to the qubit. After an optimal interaction time with negligible loss, a microwave pump releases the content of the readout mode by upconversion into a measurement line in a characteristic time as low as 10 ns, which is 400 times shorter than the lifetime of the readout resonator. A direct measurement of the released field quadratures demonstrates a readout fidelity of 97.5% in a total measurement time of 220 ns. The Wigner tomography of the readout mode allows us to characterize the non-Gaussian nature of the readout mode and its dynamics.
We present a superconducting device that realizes the sequential measurement of a transmon qubit. The unitary evolution between system and probe is indeed separated in time and space from the measurement of the probe itself. The device disables common limitations of dispersive readout such as Purcell effect or transients in the cavity mode by tuning the coupling to the measurement channel on demand. The probe is initially stored in a memory mode and coupled to the qubit until a microwave pump releases it into an output line in a characteristic time as low as 10 ns10~\mathrm{ns}10 ns, which is 400 times shorter than the memory lifetime. The Wigner function of the memory allows us to characterize the non-Gaussian nature of the probe and its dynamics. A direct measurement of the released probe field quadratures demonstrates a readout fidelity of 97.5 %97.5~\%97.5 % in a total measurement time of 220 ns220~\mathrm{ns}220 ns.