We experimentally demonstrate real-time detection of individual cesium atoms by using a high-finesse optical micro-cavity in a strong coupling regime. A cloud of cesium atoms is trapped in a magneto-optical trap positioned at 5 mm above the micro-cavity center. The atoms fall down freely in gravitation after shutting off the magneto-optical trap and pass through the cavity. The cavity transmission is strongly affected by the atoms in the cavity, which enables the micro-cavity to sense the atoms individually. We detect the single atom transits either in the resonance or various detunings. The single atom vacuum-Rabi splitting is directly measured to be Ω = 2π × 23.9 MHz. The average duration of atom-cavity coupling of about 110 μs is obtained according to the probability distribution of the atom transits.
We experimentally demonstrate real-time detection of individual cesium atoms by using a high-finesse optical micro-cavity in a strong coupling regime. A cloud of cesium atoms is trapped in a magneto-optical trap positioned at 5 mm above the micro-cavity center. The atoms fall down freely in gravitation after shutting off the magneto-optical trap and pass through the cavity. The cavity transmission is strongly affected by the atoms in the cavity, which enables the micro-cavity to sense the atoms individually. We detect the single atom transits either in the resonance or various detunings. The single atom vacuum-Rabi splitting is directly measured to be Ω = 2π × 23.9 MHz. The average duration of atom-cavity coupling of about 110 μs is obtained according to the probability distribution of the atom transits.
Summary form only given. The strong atom-photon coupling generated inside high-finesse optical micro cavity lets us detect a single atom trajectory in real time. Such a strong coupling is a candidate for trapping a single atom with a single photon. Dynamics of trapped atoms can be observed in situ and in real time by detecting intensity change on the transmission of a blue-shifted laser beam. We cooled down and trapped rubidium atoms by using conventional cell magneto optical trap (MOT) and launched them into the micro optical cavity which locates 35 mm above the MOT. By using this signal as trigger and changing the laser frequency, it is, in principle, possible to trap the atom in the cavity.
Strong coupling of single cesium atoms with a high-finesse optical micro-cavity (the finesse of our Fabry-Perot-type micro-cavity is F = 3.3 x 105 and the cavity length is lc = 86 μm) has been realized for the both cases of TEM00 and TEM10 cavity modes in our experiments. The typical parameters are (g00, κ, Υ) = 2π x (23.9, 2.6, 2.6) MHz and (g10, κ, Υ) = 2π x (20.5, 2.6, 2.6) MHz for these two cases, respectively. Obviously our system reaches the strong coupling regime. The first application is to adopt strong coupling of free-fall individual atoms with the TEM00 cavity mode for determining the effective temperature of laser-cooled atoms prepared in a magneto-optical trap located just above the micro-cavity. The second application is to employ strong coupling of free-fall individual atoms with the tilted TEM10 cavity mode, in stead of TEM00 mode, for more precisely tracking the trajectories of atoms passing through the cavity mode.
Cavity quantum electrodynamics (cavity QED) describes electromagnetic fields in a confined space and the radiative properties of atoms in such fields. The simplest example of such system is a single atom interacting with one mode of a high-finesse resonator. Besides observation and exploration of fundamental quantum mechanical effects, this system bears a high potential for applications quantum information science such as, e.g., quantum logic gates, quantum communication and quantum teleportation. In this thesis I present an experiment on the deterministic coupling of a single neutral atom to the mode of a high-finesse optical resonator. In Chapter 1 I describe our basic techniques for trapping and observing single cesium atoms. As a source of single atoms we use a high-gradient magneto-optical trap, which captures the atoms from background gas in a vacuum chamber and cools them down to millikelvin temperatures. The atoms are then transferred without loss into a standing-wave dipole trap, which provides a conservative potential required for experiments on atomic coherence such as quantum information processing and metrology on trapped atoms. Moreover, shifting the standing-wave pattern allows us to deterministically transport the atoms (Chapter 2). In combination with non-destructive fluorescence imaging of individual trapped atoms, this enables us to control their position with submicrometer precision over several millimeters along the dipole trap. The cavity QED system can distinctly display quantum behaviour in the so-called strong coupling regime, i.e., when the coherent atom-cavity coupling rate dominates dissipation in the system. This sets the main requirements on the resonator's properties: small mode volume and high finesse. Chapter 3 is devoted to the manufacturing, assembling, and testing of an ultra-high finesse optical Fabry-Perot resonator, stabilized to the atomic transition. In Chapter 4 I present the transportation of single atoms into the cavity and their coupling to the cavity mode. The strong coupling manifests itself in a strong reduction of the cavity transmission probed by a weak external laser. The atoms remain trapped and coupled to the cavity mode for several seconds until we move them out of the cavity for final analysis of their number and position.
Cavity quantum electrodynamic system with strongly coupled single atoms provides a good platform for studying quantum information processing, quantum simulation, quantum network, and distributed quantum computing. Cooling and trapping single atoms is a crucial technique in the quantum technology. At present, in a high-finesse cavity with finite space, cooling and trapping single atoms is a big challenge, even though it is a mature technique for free space. Great efforts have been made to cool and trap single atoms inside a cavity, and for a trapped atom its lifetime has reached as long as tens of seconds. Developing a more flexible method of cooling and trapping single atoms in a cavity is still essential for a strongly coupled cavity quantum electrodynamic system. In this work, we demonstrate experimentally that a single cesium atom in a cavity can be trapped by utilizing a single optical tweezer settled in cavity mode, and its lifetime is (2.60 ± 0.18) s. The experiment is carried out in a Fabry-Perot cavity, which is assembled by two concave mirrors each with a curvature radius of 100 mm, and cavity length of 335 μm. The concave surfaces are highly reflective, and the cavity has a finesse of 6.1 × 104. The 1080 nm optical tweezer with a waist of 2 μm is formed by an achromatic lens group with a numerical aperture of 0.4. At first, the precooled atomic assemble released from the magneto-optical trap (MOT) is transferred into cavity mode by an optical dipole trap with a waist of 36 μm. Then, one of the successfully transferred atoms is captured by the optical tweezer with the aid of cavity cooling mechanism. A blue detuned cavity locking laser is used as a standing-wave optical trap along the cavity axis. The signal of successfully trapped one atom is obtained by recording transmission of the cavity that will decrease owing to the strong coupling induced vacuum Rabi splitting. Finally, we demonstrate the precise manipulation of the atom-cavity coupling strength, which is achieved by scanning the position of the trapped atom step by step by using a high-precision translation stage. The system realized in this work can be used to study the dynamics of single atom-photon interactions with adjustable coupling strength. In addition, the mechanism adopted in this work is compatible with constructing tweezer arrays inside cavity mode, and thus possesses more flexibility and great potentials in cavity-based quantum entanglement and quantum simulation.
The process of single-atom transfer in strongly coupled cavity quantum electrodynamics (QED) with free falling atoms is investigated by experiment and Monte Carlo simulation. We conduct the simulation of the whole physical process and give the corresponding experimental results. In experiment, a high finesse optical cavity is used for real-time detection of the single-atom transits from which the interaction information between single atoms and cavity can be extracted, including the transmission spectra of the cavity strongly coupled to single atoms, the interaction duration of the single atoms in the mode, the probability distribution of atom arrival time and the atomic kinetic energy distribution when arriving at the mode. All these can be completely derived from the transmission spectra of the different initial status. An intracavity far-off resonance trap (FORT) has been established and the single-atom trapping time inside the cavity is about 5 ms which is about 30 times longer than that without FORT. This study gives the detailed analysis of the whole procedure of free-falling atom transfer in cavity QED system and is helpful for optimizing the experimental parameters and design.
The experiments discussed in this thesis focus on the interaction of a single trapped atom with the single mode of a high-finesse optical cavity, in the regime of strong coupling. Chapter 1 gives a brief introduction, after which Chapter 2 describes our recent measurements of the transmission spectrum of the atom-cavity system. The spectrum exhibits a clearly resolved vacuum-Rabi splitting, in good quantitative agreement with theoretical predictions. A new Raman scheme for cooling atomic motion along the cavity axis enables a complete spectrum to be recorded for an individual atom trapped within the cavity mode, in contrast to all previous measurements of this type that have required averaging over 10^3-10^5 atoms. Chapter 3 discusses our observations of photon blockade for the transmitted light in the presence of one trapped atom. Excitation of the atom-cavity system by a first photon blocks the transmission of a second one, thereby converting an incident Poissonian stream of photons into a sub-Poissonian, anti-bunched stream, as confirmed by measurements of the photon statistics of the transmitted field. The intensity correlations of the cavity transmission also reveal the energy distribution for oscillatory motion of the trapped atom. Chapter 4 details a set of simple but necessary measurements of relevant experimental parameters such as cavity geometry, linewidth, mirror properties, birefringence, and detection efficiency. The thesis concludes with Appendix A, describing the efficient laser setup we use for our magneto-optical traps.