Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Superconductivity

The quantum roulette noise thermometer

John C. Gallop, L. Hao, R.P. Reed

Published Jul 1, 1997• 9 citations
Publisher
DOI
10.1016/s0964-1807(97)00058-6

Related papers

Quantum Russian roulette

Alexandre G. M. Schmidt, Ladário da Silva

Physica A Statistical Mechanics and its Applications•Sep 11, 2012•20 citations

Quantum roulette: an extended quantum strategy

Xiang‐Bin Wang, L. C. Kwek, C. H. Oh

Physics Letters A•Dec 1, 2000•17 citations

Recipe for a Quantum Thermometer

Tamela Maciel

Physics•Jun 5, 2015•0 citations

The quantum roulette noise thermometer

Ling Yun Hao, John C. Gallop, J.C. Macfarlane +2 more

A novel form of primary thermometer called the quantum roulette noise thermometer (QRNT), based on flux quantization in a high temperature superconducting (HTS) ring, interrupted by a Josephson junction, has been proposed. The basis of the QRNT is that the flux state of the ring is allowed to evolve freely, and is repeatedly interrogated to establish a probability distribution from which the temperature of the device is derived. Unlike other superconductivity-based noise thermometers, this device is essentially dissipationless, requires no input or output connections, and may be remotely interrogated. The QRNT has the potential to provide high accuracy with short measuring times. Prototype QRNT devices based on thin HTS films have been fabricated and results of initial experimental measurements are presented. Parameters of the experimental devices are compared with predictions of the theoretical model.

IEEE Transactions on Instrumentation and Measurement•Apr 1, 1999•7 citations

The quantum roulette noise thermometer

L. Hao, J.C. Gallop, R.P. Reed +2 more

A novel form of primary thermometer called the quantum roulette noise thermometer (QRNT), based on flux quantisation in a HTS superconducting ring, has been proposed. The basis of the QRNT is that the flux state of a SQUID ring is allowed to evolve freely. The flux state is repeatedly interrogated to establish a probability distribution from which the temperature of the device is derived.

Conference on Precision Electromagnetic Measurements•Nov 27, 2002•1 citation

HTS SQUID application as a quantum roulette noise thermometer

L. Hao, John C. Gallop, R.P. Reed +2 more

We describe a cryogenic primary thermometer called the Quantum Roulette Noise Thermometer (QRNT), which is based on flux quantisation in a HTS superconducting ring. The basis of the QRNT is that the flux state of a double junction SQUID ring (in thermal contact with a heat bath whose temperature is to be measured) is allowed to evolve freely. The flux state is repeatedly interrogated to establish a probability distribution from which the absolute temperature may be derived. The QRNT is in principle dissipationless and has the potential to provide high accuracy with short measuring time. The QRNT prototype device which employs a YBCO thin film on an MgO bi-crystal substrate has been designed and fabricated. The superconducting ring of overall dimensions 6 mm/spl times/8 mm is broken by two grain boundary Josephson junctions of size 5 /spl mu/m/spl times/3 /spl mu/m. The state of the junctions is switched between superconducting and resistive by means of small currents applied to a superconducting strip line located near the junctions. A dc SQUID, which is used to read out the flux state of the QRNT ring, is operated at 77 K while the QRNT device can be set at any desired temperature above 10 K. Ongoing experimental measurements are described with reference to the expected theoretical predictions.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•3 citations
A novel form of primary thermometer called the quantum roulette noise thermometer (QRNT), based on flux quantization in a high temperature superconducting (HTS) ring, interrupted by a Josephson junction, has been proposed. The basis of the QRNT is that the flux state of the ring is allowed to evolve freely, and is repeatedly interrogated to establish a probability distribution from which the temperature of the device is derived. Unlike other superconductivity-based noise thermometers, this device is essentially dissipationless, requires no input or output connections, and may be remotely interrogated. The QRNT has the potential to provide high accuracy with short measuring times. Prototype QRNT devices based on thin HTS films have been fabricated and results of initial experimental measurements are presented. Parameters of the experimental devices are compared with predictions of the theoretical model.
We describe a cryogenic primary thermometer called the Quantum Roulette Noise Thermometer (QRNT), which is based on flux quantisation in a HTS superconducting ring. The basis of the QRNT is that the flux state of a double junction SQUID ring (in thermal contact with a heat bath whose temperature is to be measured) is allowed to evolve freely. The flux state is repeatedly interrogated to establish a probability distribution from which the absolute temperature may be derived. The QRNT is in principle dissipationless and has the potential to provide high accuracy with short measuring time. The QRNT prototype device which employs a YBCO thin film on an MgO bi-crystal substrate has been designed and fabricated. The superconducting ring of overall dimensions 6 mm/spl times/8 mm is broken by two grain boundary Josephson junctions of size 5 /spl mu/m/spl times/3 /spl mu/m. The state of the junctions is switched between superconducting and resistive by means of small currents applied to a superconducting strip line located near the junctions. A dc SQUID, which is used to read out the flux state of the QRNT ring, is operated at 77 K while the QRNT device can be set at any desired temperature above 10 K. Ongoing experimental measurements are described with reference to the expected theoretical predictions.