Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

中国物理B:英文版

Development of 1.3GHz high-T-c rf SQUID

刘新元, XIE Xiang, 孟树超, 戴远东, 李壮志, 马平, Tao Yang, 聂瑞娟, 王福仁

Published Mar 22, 2007• 0 citations
Publisher

Abstract

A new high-Tc (HTc) rf SQUID working at around 1.3GHz has been developed to avoid electromagnetic interference such as growing mobile communication jamming. This new system works in a frequency range from 1.23 to 1.42GHz (centred at 1.3GHz), which is not occupied by commercial communication. The sensor used in the 1.3GHz rf SQUID is made of a HTc coplanar superconducting resonator and a large-area HTc superconducting film concentrator. We have achieved in the 1.3GHz HTc rf SQUID system a minimal flux noise of 2.5×10^-5φ0/√Hz and a magnetic field sensitivity of 38fT/√Hz in white noise range, respectively. The effective area of the concentrator fabricated on a 15×15mm^2 substrate is 1.35mm^2. It is shown that the 1.3GHz rf SQUID system has a high field sensitivity. Design and implementation of 1.3GHz HTc rf SQUID offers a promising direction of rf SQUID development for higher working frequency ranges.

DOI
10.1088/1009-1963/10/1/014

Related papers

Operation of high-temperature rf SQUID magnetometers using dielectric SrTiO3 resonators

Y. Zhang, M. Gottschlich, Helmut Soltner +4 more

The operation of YBa2Cu3O7 rf superconducting quantum interference devices (SQUIDs) using a dielectric SrTiO3 resonator as tank circuit was tested. At 77 K, we attained for such resonators unloaded quality factors Q0 up to 7000 at resonant frequencies near 1 GHz, when measuring without electromagnetic shielding. For a washer SQUID with an area of 4×4 mm2 and an inductance of ≂100 pH, which was properly coupled to the resonator, we measured an approximately 60 μV peak-to-peak SQUID signal and a white flux noise spectral density of SΦ1/2=1×10−5Φ0/√Hz, corresponding to a field sensitivity of BN=105 fT/√Hz. With an additional single-layer flux transformer with a diameter of the pickup loop of 22 mm in flip-chip arrangement, the field sensitivity was improved to 30 fT/√Hz.

Applied Physics Letters•Nov 20, 1995•16 citations

Ultrahigh frequency thin film rf-SQUID magnetometer with a cryogenic preamplifier employing a high-electron-mobility transistor

Antonella Cavalleri, MASSIMO CERDONIO, Giorgio Fontana +5 more

Ultrahigh frequency rf-SQUID magnetometer employing a cryogenic preamplifier and a commercially available thin film rf-SQUID sensor have been designed, manufactured, and tested. The system has been operated at 316 MHz, which is the maximum pump frequency accepted by the thin film sensor. The cryogenic preamplifier has been built around a microwave high-electron-mobility transistor which was made unconditionally stable at ultrahigh frequency band by means of an appropriate circuit design, namely, a cascode configuration. The total flux noise of the magnetometer has been found to be 8.4 × 10−6Φ0/√Hz at 4.2 K and 5.8× 10−6Φ0/√Hz at 1.4 K. The temperature dependence of the fractional step rise α of the current-voltage rf characteristic has been measured to be proportional to the 2/3 power of the SQUID sensor temperature. The noise performance of the system at 4.2 K has been limited by the intrinsic SQUID noise only, in good agreement with theoretical predictions.

Review of Scientific Instruments•Nov 1, 1992•4 citations

High-TC rf superconducting quantum interference device readout with a cryogenic preamplifier

Dongfeng He, M. Tachiki, Hideo Itozaki

A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.

Review of Scientific Instruments•Jun 1, 2006•0 citations

Operation of high-sensitivity radio frequency superconducting quantum interference device magnetometers with superconducting coplanar resonators at 77 K

Y. Zhang, W. Zander, Jürgen Schubert +6 more

We have developed a novel coplanar resonator serving as a tank circuit for radio frequency washer superconducting quantum interference devices (SQUIDs). Two coplanar lines surrounded the circular flux concentrator washer, 13.4 mm in diameter. The SQUID, 3.5 mm in diameter, was coupled to the concentrator in the flip-chip configuration. All parts were fabricated from single-layer epitaxial YBa2Cu3O7 films on LaAlO3 substrates. In this layout, the resonant frequency could be set between 600 and 850 MHz. With SQUID loops of 100×100 μm2 (SQUID) inductance Ls=150 pH or 10×500 μm2 (Ls=260 pH), we determined at 77 K white flux noise levels Sφ1/2 of 1.0×10−5 and 1.5×10−5φ0/Hz, respectively. Both figures corresponded to the field resolution of about 30 fT/Hz.

Applied Physics Letters•Aug 4, 1997•54 citations

Low-noise YBa2Cu3O7 rf SQUID magnetometer

Yi Zhang, H.-M. Mück, Klaus Dieter Herrmann +4 more

A superconducting quantum interferometer device (SQUID) electronics with tank frequencies near 150 MHz was constructed to enhance the rf SQUID sensitivity. By these means we characterized our YBa2Cu3O7 thin-film rf SQUIDs with step-edge junctions immersed in liquid N2. We obtained transfer function values of over 40 μV/Φ0, at a 50 Ω input impedance, for both hysteretic and dispersive mode of rf SQUID operation. The rms white and 1/f flux noise levels were significantly lower than at the tank frequency of 20 MHz. The best magnetic field sensitivity at 77 K was 0.9 pT/Hz1/2, and the energy resolution 1.4×10−28 J/Hz, down to 0.3 Hz.

Applied Physics Letters•Feb 3, 1992•81 citations

1/f noise in radio frequency SQUIDs made of niobium thin films

Michael Mueck, John L. Clarke, Christoph Heiden

Applications of Superconducting Quantum Interference Devices (SQUIDs) usually require high sensitivity at relatively low frequencies, often down to 1 Hz or lower. Excess noise, typically with a spectral density scaling inversely as the frequency, can substantially reduce the sensitivity of SQUIDs at low frequencies. We have studied 1/f noise in niobium rf-SQUIDs in some detail. To reduce any noise contribution of the readout electronics, a cryogenic preamplifier was used. When one measures the signal voltage of the SQUID directly, a pronounced 1/f noise was observed in all samples, and was nearly independent of the bias frequency used. The crossover between 1/f and white noise moved towards higher frequencies as the bias frequency was increased, because of a lower white noise contribution. The 1/f noise scaled approximately as the inductance of the SQUID. When operated in a flux locked loop, however, no 1/f noise could be observed above 0.5 Hz. Operating a rf SQUID in a flux locked loop can thus substantially reduce 1/f noise in rf SQUIDs.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 2, 1994•0 citations
A new high-Tc (HTc) rf SQUID working at around 1.3GHz has been developed to avoid electromagnetic interference such as growing mobile communication jamming. This new system works in a frequency range from 1.23 to 1.42GHz (centred at 1.3GHz), which is not occupied by commercial communication. The sensor used in the 1.3GHz rf SQUID is made of a HTc coplanar superconducting resonator and a large-area HTc superconducting film concentrator. We have achieved in the 1.3GHz HTc rf SQUID system a minimal flux noise of 2.5×10^-5φ0/√Hz and a magnetic field sensitivity of 38fT/√Hz in white noise range, respectively. The effective area of the concentrator fabricated on a 15×15mm^2 substrate is 1.35mm^2. It is shown that the 1.3GHz rf SQUID system has a high field sensitivity. Design and implementation of 1.3GHz HTc rf SQUID offers a promising direction of rf SQUID development for higher working frequency ranges.
The operation of YBa2Cu3O7 rf superconducting quantum interference devices (SQUIDs) using a dielectric SrTiO3 resonator as tank circuit was tested. At 77 K, we attained for such resonators unloaded quality factors Q0 up to 7000 at resonant frequencies near 1 GHz, when measuring without electromagnetic shielding. For a washer SQUID with an area of 4×4 mm2 and an inductance of ≂100 pH, which was properly coupled to the resonator, we measured an approximately 60 μV peak-to-peak SQUID signal and a white flux noise spectral density of SΦ1/2=1×10−5Φ0/√Hz, corresponding to a field sensitivity of BN=105 fT/√Hz. With an additional single-layer flux transformer with a diameter of the pickup loop of 22 mm in flip-chip arrangement, the field sensitivity was improved to 30 fT/√Hz.
Ultrahigh frequency rf-SQUID magnetometer employing a cryogenic preamplifier and a commercially available thin film rf-SQUID sensor have been designed, manufactured, and tested. The system has been operated at 316 MHz, which is the maximum pump frequency accepted by the thin film sensor. The cryogenic preamplifier has been built around a microwave high-electron-mobility transistor which was made unconditionally stable at ultrahigh frequency band by means of an appropriate circuit design, namely, a cascode configuration. The total flux noise of the magnetometer has been found to be 8.4 × 10−6Φ0/√Hz at 4.2 K and 5.8× 10−6Φ0/√Hz at 1.4 K. The temperature dependence of the fractional step rise α of the current-voltage rf characteristic has been measured to be proportional to the 2/3 power of the SQUID sensor temperature. The noise performance of the system at 4.2 K has been limited by the intrinsic SQUID noise only, in good agreement with theoretical predictions.
A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.
We have developed a novel coplanar resonator serving as a tank circuit for radio frequency washer superconducting quantum interference devices (SQUIDs). Two coplanar lines surrounded the circular flux concentrator washer, 13.4 mm in diameter. The SQUID, 3.5 mm in diameter, was coupled to the concentrator in the flip-chip configuration. All parts were fabricated from single-layer epitaxial YBa2Cu3O7 films on LaAlO3 substrates. In this layout, the resonant frequency could be set between 600 and 850 MHz. With SQUID loops of 100×100 μm2 (SQUID) inductance Ls=150 pH or 10×500 μm2 (Ls=260 pH), we determined at 77 K white flux noise levels Sφ1/2 of 1.0×10−5 and 1.5×10−5φ0/Hz, respectively. Both figures corresponded to the field resolution of about 30 fT/Hz.
A superconducting quantum interferometer device (SQUID) electronics with tank frequencies near 150 MHz was constructed to enhance the rf SQUID sensitivity. By these means we characterized our YBa2Cu3O7 thin-film rf SQUIDs with step-edge junctions immersed in liquid N2. We obtained transfer function values of over 40 μV/Φ0, at a 50 Ω input impedance, for both hysteretic and dispersive mode of rf SQUID operation. The rms white and 1/f flux noise levels were significantly lower than at the tank frequency of 20 MHz. The best magnetic field sensitivity at 77 K was 0.9 pT/Hz1/2, and the energy resolution 1.4×10−28 J/Hz, down to 0.3 Hz.
Applications of Superconducting Quantum Interference Devices (SQUIDs) usually require high sensitivity at relatively low frequencies, often down to 1 Hz or lower. Excess noise, typically with a spectral density scaling inversely as the frequency, can substantially reduce the sensitivity of SQUIDs at low frequencies. We have studied 1/f noise in niobium rf-SQUIDs in some detail. To reduce any noise contribution of the readout electronics, a cryogenic preamplifier was used. When one measures the signal voltage of the SQUID directly, a pronounced 1/f noise was observed in all samples, and was nearly independent of the bias frequency used. The crossover between 1/f and white noise moved towards higher frequencies as the bias frequency was increased, because of a lower white noise contribution. The 1/f noise scaled approximately as the inductance of the SQUID. When operated in a flux locked loop, however, no 1/f noise could be observed above 0.5 Hz. Operating a rf SQUID in a flux locked loop can thus substantially reduce 1/f noise in rf SQUIDs.