Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Cavity-enhanced absorption spectroscopy of molecular oxygen

L. Gianfrani, Richard W. Fox, Leo W. Hollberg

Published Dec 1, 1999• 111 citations
Publisher

Abstract

A high-finesse optical cavity was employed to perform highly sensitive spectroscopy of molecular oxygen at wavelengths near 763 nm. An equivalent absorption length of ∼1 km was obtained by a 26-cm-long optical cavity with a finesse of 6000. An extended cavity diode laser was frequency locked to the cavity, and pure absorption profiles were recovered by monitoring of the cavity transmission during continuous scans of the cavity resonance through O2 rotational lines, allowing a detailed investigation of the line shapes. Phase modulation of the laser at a frequency equal to the cavity free-spectral-range frequency was employed for detection of weak absorption signals inside the cavity. A minimum detectable absorption coefficient of 6.9×10-11 cm-1 Hz-1/2 was measured. Finally, a test of the symmetrization postulate in 16O nuclei was demonstrated.

DOI
10.1364/josab.16.002247

Related papers

CAVITY-ENHANCED ULTRAFAST TRANSIENT ABSORPTION SPECTROSCOPY

Yuning Chen, Thomas G. Allison, Kevin Keleher +1 more

We introduce cavity enhanced ultrafast transient absorption spectroscopy, which employs frequency combs and high-finesse optical cavities. % The schematic of apparatus is shown in Figure 1. Sub-100 fs pulses with a repetition rate of 90 MHz are generated by a home-built Ytterbium fiber laser. The amplified light has a power up to 10 W, which is used to pump an optical parametric oscillator, followed by second-harmonic generation(SHG) that converts the wavelength from near-IR to visible. A pump comb at 530 nm is separately generated by SHG. Both pump and probe combs are coupled into high-finesse cavities. Compared to the conventional transient absorption spectroscopy method, the detection sensitivity can be improved by a factor of $\left(\frac{\mathcal{F}}{\pi} \right)^2 \sim 10^5$, where $\mathcal{F}$ is the finesse of cavity. This ultrasensitive technology enables the direct all-optical dynamics study in molecular beams. We will apply the cavity enhanced ultrafast transient absorption spectroscopy to investigate the dynamics of visible chromophores and then extend the wavelength to mid-IR to study vibrational dynamics of small hydrogen-bonded clusters. %\begin{wrapfigure}{I}{1\textwidth} % \centering % \includegraphics[width = 0.7\textwidth]{CETAS_details.eps} %\caption{Schematic of cavity enhanced ultrafast transient absorption spectroscopy apparatus. An amplified fiber laser frequency comb is converted to visible light and pump and probe combs are coupled to high-finesse optical resonators. Transmission of the probe light is measured.} %\end{wrapfigure}

International Symposium on Molecular Spectroscopy (ISMS)•Jun 16, 2014•0 citations

Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy

R. Engeln, Giel Berden, Rudy Peeters +1 more

It is experimentally demonstrated that a narrow band continuous wave (cw) light source can be used in combination with a high-finesse optically stable cavity to perform sensitive, high-resolution direct absorption and optical rotation spectroscopy in an amazingly simple experimental setup, using ideas from the field of cavity ring down spectroscopy. Light from a scanning narrow band cw laser is coupled into the cavity via accidental coincidences of the laser frequency with the frequency of one of the multitude of modes of the cavity. The absorption and polarization rotation information is extracted from a measurement of the time-integrated light intensity leaking out of the cavity as a function of laser wavelength.

Review of Scientific Instruments•Nov 1, 1998•347 citations

TOWARDS THE ULTIMATE OPTICAL DETECTION SENSITIVITY: NEW SPECTROSCOPIC OPPORTUNITIES- AND A ZILLION NEW WAVELENGTH/FREQUENCY STANDARDS

J. L. Hall

High sensitivity detection of quantum absorption is demonstrated at a sensitivity of $1 \\times 10^{11}$ integrated absorption, in 1 sec, using 10 mTorr total gas pressure. Achieving highly sensitive detection relies on simple basic principles: 1) The molecule-generated electric field in the forward direction (the "darkness wave") is most precious, and contains the maximum available information. It is the physical manifestation of the -$alpha^{*}$L term appearing when beer#### absorption law is expanded for low opacity, 2) After generating the molecular signal, the detected unabsorbed light sets the "shotnoise" measurement floor. We use an optical transmission cavity for the gas cell, since the high internal "build-up" field will elicit a strong molecular "darkness wave", for a given transmitted de light on the detector, A more conventional explanation of Gavity Enhancement would be the extension of the effective cell length by the factor finesse $^{*}2/\\pi.3$) To avoid excess low-frequency noise, such small signals should be measured by ac methods, comparing on-resonant and off-resonant cases in quick succession. 4) By SIMULTANEOUSLY obtaining and subtracting these cases, one provides a siginal channel with NO OUTPUT unless there is a resonance. This is conveniently accomplished by using the FM detection method with the optical heterodyne sidebands and carrier being transmitted through the cavity via adjacent axial orders 5). A remarkable property of this configuration, when the modulation frequency= cavity mode spacing, is the suppression of ANY detection of laser frequency noise with the transmitted light. We can refer to this property as (laser FM-) noise-Immune detection. This enables profitable use of cavity finesse in the range above 10,000, without a nois penalty, Altogether, we refer to this new spectroscopy as Noise-Immune, Cavity-Enhanced, Optical Heterodyne Molecular spectroscopy, i.e. "NICE OHMS". We have measured excellent saturated dispersion signals from HCCH in the band near 790 mm ($\\nu_{1} + 3 \\nu_{3}$), and recently, using a Nd:YAG source, from the HCCD P(5) line ($\\nu_{2} + 3 \\nu_{3}$) at 1064 mm. The saturation peaks broaden from the transit limit of 270 kHz near zero pressure at the rate 34.7 kHz/m Torr. We observe interesting narrow linwidths 8-fold below the transit limit, basically using optical selection of slow molecules by low power and pressure (2 mW and 2 m Torr). The absolute frequency is measurred to be 281, 635,363,960 MHz $\\pm 45$ kHz.

•Jan 1, 1996•0 citations

Rapid scanning cavity ring-down spectroscopy at the quantum noise limit

David A. Long, Adam J. Fleisher, Szymon Wójtewicz +2 more

We present an ultrasensitive cavity-enhanced technique for probing weak molecular absorptions. Recently, we have implemented heterodyne detection, which allowed for quantum-noise-limited detection and noise-equivalent absorption coefficients as low as 6×10−14 cm−1•Hz−1/2.

•Jan 1, 2014•0 citations

Optical feedback frequency stabilized cavity ring-down spectroscopy

Johannes Burkart, D. Romanini, S. Kassi

We introduce optical feedback frequency stabilized cavity ring-down spectroscopy (OFFS-CRDS), a near-shot-noise-limited technique that combines kilohertz resolution with an absorption detection sensitivity of 5×10(-13) cm(-1) Hz(-1/2). Its distributed feedback laser source is stabilized to a highly stable V-shaped reference cavity by optical feedback and fine-tuned by means of single-sideband modulation. The stability of this narrow laser is transferred to a ring-down (RD) cavity using a new fibered Pound-Drever-Hall (PDH) locking scheme without a dedicated electro-optic phase modulator, yielding several hundred RD events per second. We demonstrate continuous coverage of more than 7 nm with a baseline noise of 5×10(-12) cm(-1) and a dynamic range spanning six decades. With its resonant intracavity light intensity on the order of 1 kW/cm2, the spectrometer was used for observing a Lamb dip in a transition of carbon dioxide involving four vibrational quanta. Saturating such a weak transition at 160 μW input power, OFFS-CRDS paves the way to Doppler-free molecular overtone spectroscopy for precision measurements of hyperfine structures and pressure shifts.

Optics Letters•Aug 4, 2014•61 citations

Frequency-modulation spectroscopy with blue diode lasers

Ulf P. Gustafsson, Gabriel Somesfalean, Jānis Alnis +1 more

Frequency-modulation spectroscopy provides ultrasensitive absorption measurements. The technique is especially adaptable to diode lasers, which can be modulated easily, and has been used extensively in the near-infrared and infrared spectral regions. The availability of blue diode lasers now means that the accessible wavelength region can be increased. We successfully demonstrate wavelength-modulation spectroscopy and two-tone frequency-modulation spectroscopy for the weak second resonance line of potassium at 404.8 nm and for the transition at 405.8 nm in lead, starting from the thermally populated 6(p)(2 3)P(2) metastable level. Information on the modulation parameters is obtained with a fitting procedure. Experimental signal-to-noise ratios at different absorption levels are compared with theoretical signal-to-noise ratios and show good agreement. Detection sensitivities of 2 x 10(-6) and 5 x 10(-6) for wavelength and two-tone frequency-modulation spectroscopy, respectively, for a 120-Hz bandwidth are demonstrated.

Applied Optics•Jul 20, 2000•29 citations
A high-finesse optical cavity was employed to perform highly sensitive spectroscopy of molecular oxygen at wavelengths near 763 nm. An equivalent absorption length of ∼1 km was obtained by a 26-cm-long optical cavity with a finesse of 6000. An extended cavity diode laser was frequency locked to the cavity, and pure absorption profiles were recovered by monitoring of the cavity transmission during continuous scans of the cavity resonance through O2 rotational lines, allowing a detailed investigation of the line shapes. Phase modulation of the laser at a frequency equal to the cavity free-spectral-range frequency was employed for detection of weak absorption signals inside the cavity. A minimum detectable absorption coefficient of 6.9×10-11 cm-1 Hz-1/2 was measured. Finally, a test of the symmetrization postulate in 16O nuclei was demonstrated.
We introduce cavity enhanced ultrafast transient absorption spectroscopy, which employs frequency combs and high-finesse optical cavities. % The schematic of apparatus is shown in Figure 1. Sub-100 fs pulses with a repetition rate of 90 MHz are generated by a home-built Ytterbium fiber laser. The amplified light has a power up to 10 W, which is used to pump an optical parametric oscillator, followed by second-harmonic generation(SHG) that converts the wavelength from near-IR to visible. A pump comb at 530 nm is separately generated by SHG. Both pump and probe combs are coupled into high-finesse cavities. Compared to the conventional transient absorption spectroscopy method, the detection sensitivity can be improved by a factor of (Fπ)2∼105\left(\frac{\mathcal{F}}{\pi} \right)^2 \sim 10^5(πF​)2∼105, where F\mathcal{F}F is the finesse of cavity. This ultrasensitive technology enables the direct all-optical dynamics study in molecular beams. We will apply the cavity enhanced ultrafast transient absorption spectroscopy to investigate the dynamics of visible chromophores and then extend the wavelength to mid-IR to study vibrational dynamics of small hydrogen-bonded clusters. %\begin{wrapfigure}{I}{1\textwidth} % \centering % \includegraphics[width = 0.7\textwidth]{CETAS_details.eps} %\caption{Schematic of cavity enhanced ultrafast transient absorption spectroscopy apparatus. An amplified fiber laser frequency comb is converted to visible light and pump and probe combs are coupled to high-finesse optical resonators. Transmission of the probe light is measured.} %\end{wrapfigure}
It is experimentally demonstrated that a narrow band continuous wave (cw) light source can be used in combination with a high-finesse optically stable cavity to perform sensitive, high-resolution direct absorption and optical rotation spectroscopy in an amazingly simple experimental setup, using ideas from the field of cavity ring down spectroscopy. Light from a scanning narrow band cw laser is coupled into the cavity via accidental coincidences of the laser frequency with the frequency of one of the multitude of modes of the cavity. The absorption and polarization rotation information is extracted from a measurement of the time-integrated light intensity leaking out of the cavity as a function of laser wavelength.
High sensitivity detection of quantum absorption is demonstrated at a sensitivity of 1times10111 \\times 10^{11}1times1011 integrated absorption, in 1 sec, using 10 mTorr total gas pressure. Achieving highly sensitive detection relies on simple basic principles: 1) The molecule-generated electric field in the forward direction (the "darkness wave") is most precious, and contains the maximum available information. It is the physical manifestation of the -alpha∗alpha^{*}alpha∗L term appearing when beer#### absorption law is expanded for low opacity, 2) After generating the molecular signal, the detected unabsorbed light sets the "shotnoise" measurement floor. We use an optical transmission cavity for the gas cell, since the high internal "build-up" field will elicit a strong molecular "darkness wave", for a given transmitted de light on the detector, A more conventional explanation of Gavity Enhancement would be the extension of the effective cell length by the factor finesse ∗2/pi.3^{*}2/\\pi.3∗2/pi.3) To avoid excess low-frequency noise, such small signals should be measured by ac methods, comparing on-resonant and off-resonant cases in quick succession. 4) By SIMULTANEOUSLY obtaining and subtracting these cases, one provides a siginal channel with NO OUTPUT unless there is a resonance. This is conveniently accomplished by using the FM detection method with the optical heterodyne sidebands and carrier being transmitted through the cavity via adjacent axial orders 5). A remarkable property of this configuration, when the modulation frequency= cavity mode spacing, is the suppression of ANY detection of laser frequency noise with the transmitted light. We can refer to this property as (laser FM-) noise-Immune detection. This enables profitable use of cavity finesse in the range above 10,000, without a nois penalty, Altogether, we refer to this new spectroscopy as Noise-Immune, Cavity-Enhanced, Optical Heterodyne Molecular spectroscopy, i.e. "NICE OHMS". We have measured excellent saturated dispersion signals from HCCH in the band near 790 mm (nu1+3nu3\\nu_{1} + 3 \\nu_{3}nu1​+3nu3​), and recently, using a Nd:YAG source, from the HCCD P(5) line (nu2+3nu3\\nu_{2} + 3 \\nu_{3}nu2​+3nu3​) at 1064 mm. The saturation peaks broaden from the transit limit of 270 kHz near zero pressure at the rate 34.7 kHz/m Torr. We observe interesting narrow linwidths 8-fold below the transit limit, basically using optical selection of slow molecules by low power and pressure (2 mW and 2 m Torr). The absolute frequency is measurred to be 281, 635,363,960 MHz pm45\\pm 45pm45 kHz.
We introduce optical feedback frequency stabilized cavity ring-down spectroscopy (OFFS-CRDS), a near-shot-noise-limited technique that combines kilohertz resolution with an absorption detection sensitivity of 5×10(-13) cm(-1) Hz(-1/2). Its distributed feedback laser source is stabilized to a highly stable V-shaped reference cavity by optical feedback and fine-tuned by means of single-sideband modulation. The stability of this narrow laser is transferred to a ring-down (RD) cavity using a new fibered Pound-Drever-Hall (PDH) locking scheme without a dedicated electro-optic phase modulator, yielding several hundred RD events per second. We demonstrate continuous coverage of more than 7 nm with a baseline noise of 5×10(-12) cm(-1) and a dynamic range spanning six decades. With its resonant intracavity light intensity on the order of 1 kW/cm2, the spectrometer was used for observing a Lamb dip in a transition of carbon dioxide involving four vibrational quanta. Saturating such a weak transition at 160 μW input power, OFFS-CRDS paves the way to Doppler-free molecular overtone spectroscopy for precision measurements of hyperfine structures and pressure shifts.
Frequency-modulation spectroscopy provides ultrasensitive absorption measurements. The technique is especially adaptable to diode lasers, which can be modulated easily, and has been used extensively in the near-infrared and infrared spectral regions. The availability of blue diode lasers now means that the accessible wavelength region can be increased. We successfully demonstrate wavelength-modulation spectroscopy and two-tone frequency-modulation spectroscopy for the weak second resonance line of potassium at 404.8 nm and for the transition at 405.8 nm in lead, starting from the thermally populated 6(p)(2 3)P(2) metastable level. Information on the modulation parameters is obtained with a fitting procedure. Experimental signal-to-noise ratios at different absorption levels are compared with theoretical signal-to-noise ratios and show good agreement. Detection sensitivities of 2 x 10(-6) and 5 x 10(-6) for wavelength and two-tone frequency-modulation spectroscopy, respectively, for a 120-Hz bandwidth are demonstrated.