We show that a single-cell spin-exchange relaxation-free (SERF) atomic magnetometer can be used for 3-D field measurements. The 3-D operation is achieved by optically pumping the magnetometer cell in successive layers perpendicular to the laser probe beam and by collecting the signals with a photodiode array. The vapor cell is thus divided into voxels acting as local atomic magnetometers. Each voxel's contribution to the probe linear polarization rotation is proportional to the convolution of the local polarization and the magnetic field. The layers are pumped in sequence without waiting for the atomic polarization in the previously pumped layer to relax to zero, consequently, reducing the total measurement time. The photodiode signals are the sum of accumulated linear polarization rotation caused by all the layers. These signals are processed by a deconvolution algorithm that extracts the information originating from each individual voxel. Our theoretical analysis and experimental results show that the time of a single-layer pumping can be reduced below the atomic-cell relaxation time constant, with almost no loss of precision.
We show that a single-cell spin-exchange relaxation-free (SERF) atomic magnetometer can be used for 3-D field measurements. The 3-D operation is achieved by optically pumping the magnetometer cell in successive layers perpendicular to the laser probe beam and by collecting the signals with a photodiode array. The vapor cell is thus divided into voxels acting as local atomic magnetometers. Each voxel's contribution to the probe linear polarization rotation is proportional to the convolution of the local polarization and the magnetic field. The layers are pumped in sequence without waiting for the atomic polarization in the previously pumped layer to relax to zero, consequently, reducing the total measurement time. The photodiode signals are the sum of accumulated linear polarization rotation caused by all the layers. These signals are processed by a deconvolution algorithm that extracts the information originating from each individual voxel. Our theoretical analysis and experimental results show that the time of a single-layer pumping can be reduced below the atomic-cell relaxation time constant, with almost no loss of precision.
The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.
The most efficient way to improve the sensitivity of an optically pumped magnetometer (OPM) is to maximize the spin-polarization lifetime of the atoms. The spin exchange relaxation-free (SERF) OPM that operates in zero field environment is one of the most sensitive magnetic sensors. This paper proposes a new three-axis magnetic field compensation method for the single-beam OPM, which zeroes the magnetic field around the sensor to make it work in SERF regime. The method simultaneously employs two modulation magnetic fields and two low-frequency sweeping magnetic fields along two directions perpendicular to the laser beam during the compensation process. The output signal of the photodiode is demodulated at different frequencies, resulting in two outputs that reflect the three components of the magnetic field. This method does not require iterate to tune the three-axis field, which increases the speed of the compensation process significantly. The magnetic field resolutions of the method for the x-axis, y-axis and z-axis are 0.6 pT, 0.6 pT and 5 pt, respectively. A compact OPM with noise density about 20 fT / Hz1/2@10 Hz is developed and tested, demonstrating the feasibility of the method.
A miniature wide-range three-axis vector atomic magnetometer under spin-exchange relaxation-free regime has been developed. With a cylindrical vapor cell of size 10 mm in diameter and length, we have constructed a single-beam configuration through a polarization-maintaining fiber carrying the laser beam to the sensor and a multimode fiber guiding the transmitted light field to the photodiode. A rotating field on the plane perpendicular to the direction of propagation of the laser and another modulation field in the pump direction, which are generated in the field programmable gate array using direct digital synthesis to measure the three components of the magnetic field simultaneously. The spin-exchange relaxation is suppressed in zero field controlled by a feedback system, thus a wide range and excellent accuracy of three-axis vector atomic magnetometer response is obtained. Consequently, the transverse magnetic field sensitivity of 350 fT/Hz1/2and longitudinal field sensitivity of 3pT/Hz1/2are achieved with a dynamic range of 60000 nT. This sensor with compact size, wide range and high sensitivity is particularly suitable for geomagnetic observatory and space exploration.
High-sensitivity multi-channel atomic magnetometers are described. Methods for operating multi-channel atomic magnetometers are also described. Moreover, devices incorporating a plurality of multi-channel atomic magnetometers are described. A multi-channel atomic magnetometer may use the spin-exchange relaxation-free (SERF) technique. A multi-channel atomic magnetometer may achieve multi-channel operation in a single module, reducing the cost of sensors. A multi-channel atomic magnetometer may be a 16-channel atomic magnetometer. A multi-channel atomic magnetometer may include a single large vapor cell including alkali-metal atoms and at least one buffer gas that restricts motion of atomic spins of the alkali-metal atoms, thereby making relatively small internal cell volumes act as a multiple independent local sensing channels. A multi-channel atomic magnetometer may include a broad pump beam that simultaneously polarizes all (or substantially all) of the alkali-metal atoms in each internal sensing volume of the vapor cell, and a broad probe beam that simultaneously measures magnetic fields at multiple sensing volumes with a photodiode array.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.