Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control

Frequency measurement of the 2S1/2_2D3/2 electric quadrupole transition in a single 171yb+ ion

Stephen A. Webster, R. M. Godun, S. A. King, Guilong Huang, Barney Walton, Veronika Tsatourian, Helen S. Margolis, S.N. Lea, Patrick Robert Gill

Published Mar 1, 2010• 19 citations
Publisher

Abstract

We report on precision laser spectroscopy of the 2S(1/2)(F = 0)-2D(3/2) (F = 2, m(F) = 0) clock transition in a single ion of 171Yb+. The absolute value of the transition frequency, determined using an optical frequency comb referenced to a hydrogen maser, is 688358979309310 +/- 9 Hz. This corresponds to a fractional frequency uncertainty of 1.3 x 10(-14).

DOI
10.1109/tuffc.2010.1452

Related papers

Frequency measurement of the 2S1/2 – 2D3/2 electric quadrupole transition in a single 171Yb+ ion

Stephen A. Webster, R. M. Godun, S. A. King +6 more

We report on precision laser spectroscopy of the2S1/2(F = 0) -2D3/2(F = 2, mF= 0) clock transition in a single ion of171Yb+. The absolute value of the transition frequency, determined using an optical frequency comb referenced to a hydrogen maser, is 688 358 979 309 310 plusmn 9 Hz. This corresponds to a fractional uncertainty of 1.3 times 10-14.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•0 citations

Optical frequency standard based on a trapped171Yb+ion

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The 435.5 nm electric-quadrupole transition from the 2S1/2(F=0) groudn state to the 2D3/2(F=2) state is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Foruier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency is determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 321 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1×10-14.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 8, 2003•0 citations

Precision frequency measurement of the 2S1/2 — 2F7/2 electric octupole transition in a single 171Yb+ ion

Stephen A. Webster, Kazumoto Hosaka, Barney Walton +2 more

We report precision laser spectroscopy of the2S1/2(F = 0, mF=0)-2F7/2(F =3, mF= 0) clock transition in a single, trapped, laser cooled ion of171Yb+. The absolute frequency is measured to be 642 121 496 772 656 (12) Hz, a factor of 20 more accurate than previous measurements.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•5 citations

Frequency measurement of the S21/2−F27/2 electric octupole transition in a single Y171b+ ion

Kazumoto Hosaka, Stephen A. Webster, A. F. B. Stannard +3 more

We report on precision laser spectroscopy of the ${^{2}S}_{1/2}(F=0)\text{\ensuremath{-}}{^{2}F}_{7/2}(F=3,{m}_{F}=0)$ clock transition in a single ion of ${^{171}\text{Y}\text{b}}^{+}$. A linewidth of $<40\text{ }\text{Hz}$ is observed and frequency instability due to fluctuation of the ac Stark shift is reduced through improved stability of the beam alignment. The absolute value of the transition frequency, determined using an optical frequency comb, is $642\text{ }121\text{ }496\text{ }772\text{ }657\ifmmode\pm\else\textpm\fi{}12\text{ }\text{Hz}$ with a fractional uncertainty of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$. This is a factor of 50 better than the previously published value [Hosaka et al., IEEE Trans. Instrum. Meas. 54, 759 (2005)].

Physical Review A•Mar 10, 2009•55 citations

Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion

Helen S. Margolis, G. P. Barwood, Guozheng Huang +4 more

The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.

Science•Nov 18, 2004•302 citations

Frequency Measurement of the Electric Quadrupole Transition in a Single Laser-Cooled 40 Ca +

Qu Liu, Yao Huang, Jian Zhong Cao +5 more

The optical frequency of the 4s 2 S 1/2 -3d 2 D 5/2 transition in a single trapped and laser-cooled 40 Ca + ion is measured with an optical frequency comb system referenced to a hydrogen maser. A 729-nm laser can be locked to the clock transition about ten hours and the Allan deviation is better than 2 × 10 −14 /1000 s.

Chinese Physics Letters•Jan 1, 2011•13 citations
We report on precision laser spectroscopy of the 2S(1/2)(F = 0)-2D(3/2) (F = 2, m(F) = 0) clock transition in a single ion of 171Yb+. The absolute value of the transition frequency, determined using an optical frequency comb referenced to a hydrogen maser, is 688358979309310 +/- 9 Hz. This corresponds to a fractional frequency uncertainty of 1.3 x 10(-14).
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The 435.5 nm electric-quadrupole transition from the 2S1/2(F=0) groudn state to the 2D3/2(F=2) state is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Foruier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency is determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 321 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1×10-14.
We report on precision laser spectroscopy of the ${^{2}S}_{1/2}(F=0)\text{\ensuremath{-}}{^{2}F}_{7/2}(F=3,{m}_{F}=0)$ clock transition in a single ion of 171Yb+{^{171}\text{Y}\text{b}}^{+}171Yb+. A linewidth of <40 Hz<40\text{ }\text{Hz}<40 Hz is observed and frequency instability due to fluctuation of the ac Stark shift is reduced through improved stability of the beam alignment. The absolute value of the transition frequency, determined using an optical frequency comb, is $642\text{ }121\text{ }496\text{ }772\text{ }657\ifmmode\pm\else\textpm\fi{}12\text{ }\text{Hz}$ with a fractional uncertainty of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$. This is a factor of 50 better than the previously published value [Hosaka et al., IEEE Trans. Instrum. Meas. 54, 759 (2005)].
The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.