IEEE Transactions on Applied Superconductivity

An 800 GHz NbN phonon-cooled hot-electron bolometer mixer receiver

Jonathan H. Kawamura, Edward Tong, R. Blundell, D. C. Papa, T. R. Hunter, G. N. Gol'tsman, Serguei Cherednichenko, B. Voronov, Eugene M. Gershenzon

Published Jun 1, 1999• 13 citations
Publisher

Abstract

We describe a heterodyne receiver developed for astronomical applications to operate in the 350 /spl mu/m atmospheric window. The waveguide receiver employs a superconductive NbN phonon-cooled hot-electron bolometer mixer. The double sideband receiver noise temperature closely follows 1 kGHz/sup -1/ across 780-870 GHz, with the intermediate frequency centered at 1.4 GHz. The conversion loss is about 15 dB. The receiver was installed for operation at the University of Arizona/Max Planck Institute for Radio Astronomy Submillimeter Telescope facility. The instrument was successfully used to conduct test observations of a number of celestial sources in a number of astronomically important spectral lines.

DOI
10.1109/77.783844

Related papers

A 1-THz Superconducting Hot-Electron-Bolometer Receiver for Astronomical Observations

Denis Meledin, Daniel P. Marrone, Edward Tong +9 more

In this paper, we describe a superconducting hot-electron-bolometer mixer receiver developed to operate in atmospheric windows between 800-1300 GHz. The receiver uses a waveguide mixer element made of 3-4-nm-thick NbN film deposited over crystalline quartz. This mixer yields double-sideband receiver noise temperatures of 1000 K at around 1.0 THz, and 1600 K at 1.26 THz, at an IF of 3.0 GHz. The receiver was successfully tested in the laboratory using a gas cell as a spectral line test source. It is now in use on the Smithsonian Astrophysical Observatory terahertz test telescope in northern Chile.

IEEE Transactions on Microwave Theory and Techniques•Oct 1, 2004•37 citations

Superconductive hot-electron-bolometer mixer receiver for 800-GHz operation

Jonathan H. Kawamura, R. Blundell, Edward Tong +8 more

In this paper, we describe a superconductive hot-electron-bolometer mixer receiver designed to operate in the partially transmissive 350-/spl mu/m atmospheric window. The receiver employs an NbN thin-film microbridge as the mixer element, in which the main cooling mechanism of the hot electrons is through electron-phonon interaction. At a local-oscillator frequency of 808 GHz, the measured double-sideband receiver noise temperature is T/sub RX/=970 K, across a 1-GHz intermediate-frequency bandwidth centered at 1.8 GHz. We have measured the linearity of the receiver and the amount of local-oscillator power incident on the mixer for optimal operation, which is P/sub LO//spl ap/1 /spl mu/W. This receiver was used in making observations as a facility instrument at the Heinrich Hertz Telescope, Mt. Graham, AZ, during the 1998-1999 winter observing season.

IEEE Transactions on Microwave Theory and Techniques•Apr 1, 2000•22 citations

Terahertz-frequency waveguide NbN hot-electron bolometer mixer

Jonathan H. Kawamura, Edward Tong, R. Blundell +5 more

We have developed a low-noise waveguide heterodyne receiver for operation near 1 THz using phonon-cooled NbN hot-electron bolometers. The mixer elements are submicron-sized microbridges of 4 nm-thick NbN film fabricated on a quartz substrate. Operating at a bath temperature of 4.2 K, the double-sideband receiver noise temperature is 760 K at 1.02 THz and 1100 K at 1.26 THz. The local oscillator is provided by solid-state sources, and power measured at the source is less than 1 /spl mu/W. The intermediate frequency bandwidth exceeds 2 GHz. The receiver was used to make the first ground-based heterodyne detection of a celestial spectroscopic line above 1 THz.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•24 citations

Superconducting hot electron bolometer as mixer for far-infrared heterodyne receivers

Heinz‐Wilhelm Hübers, Alexei D. Semenov, Heiko Richter +6 more

Heterodyne receivers for applications in astronomy need quantum limited sensitivity. In instruments which are currently under development for SOFIA or Herschel superconducting hot electron bolometers (HEB) will be used to achieve this goal at frequencies above 1.4 THz. We present results of the development of a phonon-cooled NbN HEB mixer for GREAT, the German Receiver for Astronomy at Terahertz Frequencies, which will be flown aboard SOFIA. The mixer is a small superconducting bridge incorporated in a planar feed antenna and a hyperhemispherical lens. Mixers with logarithmic-spiral and double-slot feed antennas have been investigated with respect to their noise temperature, conversion loss, linearity and beam pattern. At 2.5 THz a double sideband noise temperature of 2200 K was achieved. The conversion loss was 17 dB. The response of the mixer was linear up to 400 K load temperature. The performance was verified by measuring an emission line of methanol at 2.5 THz. The measured linewidth is in good agreement with the linewidth deduced from pressure broadening measurements at millimeter wavelength. The results demonstrate that the NbN HEB is very well suited as a mixer for far-infrared heterodyne receivers.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 1, 2003•0 citations

First Light with an 800 GHz Phonon-Cooled HEB Mixer Receiver

Jonathan H. Kawamura, R. Blundell, Edward Tong +6 more

Phonon-cooled superconductive hot-electron bolometric (HEB) mixers are incorporated in a waveguide receiver designed to operate near 800 Gliz. The mixer elements are thin-film niobium nitride microbridges with dimensions of 4 nm thickness, 0.2 to 0.3 p.m in length and 2 jun in width. At 780 GHz the best receiver noise temperature is 840 K (DSB). The mixer IF bandwidth is 2.0 GHz, the absorbed LO power is —0.1 1.1W. A fixed-tuned version of the receiver was installed at the Submillimeter Telescope Observatory on Mt. Graham, Arizona, to conduct astronomical observations. These observations represent the first time that a receiver incorporating any superconducting HEB mixer has been used to detect a spectral line of celestial origin. Introduction Superconducting HEB mixers look to become the technology of choice for heterodyne detection above 1 THz. This technology has thus far fulfilled, in the laboratory at least, all the basic requirements for efficient astronomical observing at subraillimeter wavelengths: low-noise performance, low local oscillator power requirement and large intermediate frequency bandwidth. However, performance in the laboratory is often a poor substitute for performance in the field. Even with the detection of molecular lines in the laboratory with this type of receiver, many people, in particular potential users, remain cautiously skeptical about whether or not this new technology will be useful in practice. In order to address this final concern directly, we have aimed our efforts in the past six months to build a complete receiver system employing a superconducting HEB mixer to take to a submillimeter telescope facility and test its performance definitively. Our receiver employs a phonon-cooled HEB mixer [1] fabricated from niobium nitride [2]. The mixer elements are thin-film microbridges with typical thickness of 4 nm fabricated on crystalline quartz substrates. The critical temperature, T„ is —9 K. with a transition width of —1 K. The sheet resistance ranges from 1000 to 2000 Over the course of our experiments [3], we have learned that all of our mixers fabricated using conventional optical photolithography require more local-oscillator power present address: Caltech 320-47, Pasadena, CA 91125 than can be conveniently provided by frequency multiplied solid-state sources, especially at the highest frequencies. For example, we were able to pump an 800 GHz mixer at only two frequency points. Furthermore, with optical lithography it is difficult to make a mixer that has simultaneously a low impedance and low LO power requirement. Since our goal was to build a receiver for a telescope, we absolutely needed to be able to pump the mixer continuously across the operating band of the receiver. Also, we desired to lower the mixer impedance from about 400 or so, which was typical of optically fabricated mixers, to about 100 S2. For a phonon-cooled mixer the optimal LO power simply scales with the volume of the microbridge. With the thickness fixed, the area of the mixer can be flexibly adjusted in order to give a wide range in impedance and in the level of localoscillator power. We have therefore fabricated NbN microbridges defined by electron beam lithography that have in-plane areas —10 times smaller than those manufactured for our previous studies. Such mixers have LO power requirement reduced by 10 dB compared to that of larger mixers. The mixers also have favorably lower impedance. In this paper we state the performance of our HEB receiver, and show results of its operation on a telescope. Receiver Performance A current-voltage curve of a mixer is shown in Figure 1. This mixer is 2 gm wide and 0.3 puri long, with a normal room-temperature resistance of 90 Q. The general shape of the IV curve is similar to the larger mixers. One major difference, however, is that the voltage scale is compressed in the voltage-total IF power curve, which is also plotted in the figure. This difference is a clue that the new mixer will require less local-oscillator power and dc power to reach the optimal operating point. Incidentally, this difference also has interesting consequences for the mixer saturation level, which is discussed below. The mixer is incorporated in a waveguide block with a mechanically driven backshort. The block was designed to accommodate an SIS mixer, the details of which can be found in [4]. The corrugated feed illuminates a cold off-axis paraboloid and an optical flat before exiting the cryostat. Several layers of porous Teflon provides near-infrared filtering, and a 0.5 mm Teflon window seals the cryostat. The local-oscillator is a multiplied solid-state source, and a Martin-Puplett diplexer is used to combine the local-oscillator and signal beams. Receiver noise temperature The sensitivity of the receiver was measured using the standard Y-factor technique of alternatively placing a room temperature load and a cold load at the temperature of liquid nitrogen at the input of the receiver. No corrections were made. We were able to make a continuous measurement of the receiver noise temperature across the operating band of the local-oscillator source. The noise performance across the 800 GHz band is plotted in Figure 2, and across the band, the noise temperature is always less than 2 K GHz -1 . The best noise temperature at 780 GHz is 850 K, where we estimate that the conversion loss is 14 dB and that Lax= 750 K. The receiver will actually work all the way down to the cutoff frequency of the waveguide, which is near 600 GHz.

Softwaretechnik-Trends•Mar 1, 1998•7 citations

Superconducting hot-electron bolometer mixer for terahertz heterodyne receivers

Alexei D. Semenov, Heinz‐Wilhelm Hübers, Heiko Richter +11 more

We present recent results showing the development of superconducting NbN hot-electron bolometer mixer for German receiver for astronomy at terahertz frequencies and terahertz limb sounder. The mixer is incorporated into a planar feed antenna, which has either logarithmic spiral or double-slot configuration, and backed on a silicon lens. The hybrid antenna had almost frequency independent and symmetric radiation pattern slightly broader than expected for a diffraction limited antenna. At 2.5 THz the best 2200 K double side-band receiver noise temperature was achieved across a 1 GHz intermediate frequency bandwidth centred at 1.5 GHz. For this operation regime, a receiver conversion efficiency of -17 dB was directly measured and the loss budget was evaluated. The mixer response was linear at load temperatures smaller than 400 K. Implementation of the MgO buffer layer on Si resulted in an increased 5.2 GHz gain bandwidth. The receiver was tested in the laboratory environment by measuring a methanol emission line at 2.5 THz.

IEEE Transactions on Applied Superconductivity•Jun 1, 2003•23 citations
We describe a heterodyne receiver developed for astronomical applications to operate in the 350 /spl mu/m atmospheric window. The waveguide receiver employs a superconductive NbN phonon-cooled hot-electron bolometer mixer. The double sideband receiver noise temperature closely follows 1 kGHz/sup -1/ across 780-870 GHz, with the intermediate frequency centered at 1.4 GHz. The conversion loss is about 15 dB. The receiver was installed for operation at the University of Arizona/Max Planck Institute for Radio Astronomy Submillimeter Telescope facility. The instrument was successfully used to conduct test observations of a number of celestial sources in a number of astronomically important spectral lines.
In this paper, we describe a superconducting hot-electron-bolometer mixer receiver developed to operate in atmospheric windows between 800-1300 GHz. The receiver uses a waveguide mixer element made of 3-4-nm-thick NbN film deposited over crystalline quartz. This mixer yields double-sideband receiver noise temperatures of 1000 K at around 1.0 THz, and 1600 K at 1.26 THz, at an IF of 3.0 GHz. The receiver was successfully tested in the laboratory using a gas cell as a spectral line test source. It is now in use on the Smithsonian Astrophysical Observatory terahertz test telescope in northern Chile.
In this paper, we describe a superconductive hot-electron-bolometer mixer receiver designed to operate in the partially transmissive 350-/spl mu/m atmospheric window. The receiver employs an NbN thin-film microbridge as the mixer element, in which the main cooling mechanism of the hot electrons is through electron-phonon interaction. At a local-oscillator frequency of 808 GHz, the measured double-sideband receiver noise temperature is T/sub RX/=970 K, across a 1-GHz intermediate-frequency bandwidth centered at 1.8 GHz. We have measured the linearity of the receiver and the amount of local-oscillator power incident on the mixer for optimal operation, which is P/sub LO//spl ap/1 /spl mu/W. This receiver was used in making observations as a facility instrument at the Heinrich Hertz Telescope, Mt. Graham, AZ, during the 1998-1999 winter observing season.
We have developed a low-noise waveguide heterodyne receiver for operation near 1 THz using phonon-cooled NbN hot-electron bolometers. The mixer elements are submicron-sized microbridges of 4 nm-thick NbN film fabricated on a quartz substrate. Operating at a bath temperature of 4.2 K, the double-sideband receiver noise temperature is 760 K at 1.02 THz and 1100 K at 1.26 THz. The local oscillator is provided by solid-state sources, and power measured at the source is less than 1 /spl mu/W. The intermediate frequency bandwidth exceeds 2 GHz. The receiver was used to make the first ground-based heterodyne detection of a celestial spectroscopic line above 1 THz.
Heterodyne receivers for applications in astronomy need quantum limited sensitivity. In instruments which are currently under development for SOFIA or Herschel superconducting hot electron bolometers (HEB) will be used to achieve this goal at frequencies above 1.4 THz. We present results of the development of a phonon-cooled NbN HEB mixer for GREAT, the German Receiver for Astronomy at Terahertz Frequencies, which will be flown aboard SOFIA. The mixer is a small superconducting bridge incorporated in a planar feed antenna and a hyperhemispherical lens. Mixers with logarithmic-spiral and double-slot feed antennas have been investigated with respect to their noise temperature, conversion loss, linearity and beam pattern. At 2.5 THz a double sideband noise temperature of 2200 K was achieved. The conversion loss was 17 dB. The response of the mixer was linear up to 400 K load temperature. The performance was verified by measuring an emission line of methanol at 2.5 THz. The measured linewidth is in good agreement with the linewidth deduced from pressure broadening measurements at millimeter wavelength. The results demonstrate that the NbN HEB is very well suited as a mixer for far-infrared heterodyne receivers.
Phonon-cooled superconductive hot-electron bolometric (HEB) mixers are incorporated in a waveguide receiver designed to operate near 800 Gliz. The mixer elements are thin-film niobium nitride microbridges with dimensions of 4 nm thickness, 0.2 to 0.3 p.m in length and 2 jun in width. At 780 GHz the best receiver noise temperature is 840 K (DSB). The mixer IF bandwidth is 2.0 GHz, the absorbed LO power is —0.1 1.1W. A fixed-tuned version of the receiver was installed at the Submillimeter Telescope Observatory on Mt. Graham, Arizona, to conduct astronomical observations. These observations represent the first time that a receiver incorporating any superconducting HEB mixer has been used to detect a spectral line of celestial origin. Introduction Superconducting HEB mixers look to become the technology of choice for heterodyne detection above 1 THz. This technology has thus far fulfilled, in the laboratory at least, all the basic requirements for efficient astronomical observing at subraillimeter wavelengths: low-noise performance, low local oscillator power requirement and large intermediate frequency bandwidth. However, performance in the laboratory is often a poor substitute for performance in the field. Even with the detection of molecular lines in the laboratory with this type of receiver, many people, in particular potential users, remain cautiously skeptical about whether or not this new technology will be useful in practice. In order to address this final concern directly, we have aimed our efforts in the past six months to build a complete receiver system employing a superconducting HEB mixer to take to a submillimeter telescope facility and test its performance definitively. Our receiver employs a phonon-cooled HEB mixer [1] fabricated from niobium nitride [2]. The mixer elements are thin-film microbridges with typical thickness of 4 nm fabricated on crystalline quartz substrates. The critical temperature, T„ is —9 K. with a transition width of —1 K. The sheet resistance ranges from 1000 to 2000 Over the course of our experiments [3], we have learned that all of our mixers fabricated using conventional optical photolithography require more local-oscillator power present address: Caltech 320-47, Pasadena, CA 91125 than can be conveniently provided by frequency multiplied solid-state sources, especially at the highest frequencies. For example, we were able to pump an 800 GHz mixer at only two frequency points. Furthermore, with optical lithography it is difficult to make a mixer that has simultaneously a low impedance and low LO power requirement. Since our goal was to build a receiver for a telescope, we absolutely needed to be able to pump the mixer continuously across the operating band of the receiver. Also, we desired to lower the mixer impedance from about 400 or so, which was typical of optically fabricated mixers, to about 100 S2. For a phonon-cooled mixer the optimal LO power simply scales with the volume of the microbridge. With the thickness fixed, the area of the mixer can be flexibly adjusted in order to give a wide range in impedance and in the level of localoscillator power. We have therefore fabricated NbN microbridges defined by electron beam lithography that have in-plane areas —10 times smaller than those manufactured for our previous studies. Such mixers have LO power requirement reduced by 10 dB compared to that of larger mixers. The mixers also have favorably lower impedance. In this paper we state the performance of our HEB receiver, and show results of its operation on a telescope. Receiver Performance A current-voltage curve of a mixer is shown in Figure 1. This mixer is 2 gm wide and 0.3 puri long, with a normal room-temperature resistance of 90 Q. The general shape of the IV curve is similar to the larger mixers. One major difference, however, is that the voltage scale is compressed in the voltage-total IF power curve, which is also plotted in the figure. This difference is a clue that the new mixer will require less local-oscillator power and dc power to reach the optimal operating point. Incidentally, this difference also has interesting consequences for the mixer saturation level, which is discussed below. The mixer is incorporated in a waveguide block with a mechanically driven backshort. The block was designed to accommodate an SIS mixer, the details of which can be found in [4]. The corrugated feed illuminates a cold off-axis paraboloid and an optical flat before exiting the cryostat. Several layers of porous Teflon provides near-infrared filtering, and a 0.5 mm Teflon window seals the cryostat. The local-oscillator is a multiplied solid-state source, and a Martin-Puplett diplexer is used to combine the local-oscillator and signal beams. Receiver noise temperature The sensitivity of the receiver was measured using the standard Y-factor technique of alternatively placing a room temperature load and a cold load at the temperature of liquid nitrogen at the input of the receiver. No corrections were made. We were able to make a continuous measurement of the receiver noise temperature across the operating band of the local-oscillator source. The noise performance across the 800 GHz band is plotted in Figure 2, and across the band, the noise temperature is always less than 2 K GHz -1 . The best noise temperature at 780 GHz is 850 K, where we estimate that the conversion loss is 14 dB and that Lax= 750 K. The receiver will actually work all the way down to the cutoff frequency of the waveguide, which is near 600 GHz.
We present recent results showing the development of superconducting NbN hot-electron bolometer mixer for German receiver for astronomy at terahertz frequencies and terahertz limb sounder. The mixer is incorporated into a planar feed antenna, which has either logarithmic spiral or double-slot configuration, and backed on a silicon lens. The hybrid antenna had almost frequency independent and symmetric radiation pattern slightly broader than expected for a diffraction limited antenna. At 2.5 THz the best 2200 K double side-band receiver noise temperature was achieved across a 1 GHz intermediate frequency bandwidth centred at 1.5 GHz. For this operation regime, a receiver conversion efficiency of -17 dB was directly measured and the loss budget was evaluated. The mixer response was linear at load temperatures smaller than 400 K. Implementation of the MgO buffer layer on Si resulted in an increased 5.2 GHz gain bandwidth. The receiver was tested in the laboratory environment by measuring a methanol emission line at 2.5 THz.