Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment

A magnetic trap for antihydrogen confinement

William Alan Bertsche, A.J. Boston, Paul David Bowe, Claudio Lenz Cesar, S. Chapman, M. Charlton, M. Chartier, A. Deutsch, J. Fajans, M. Fujiwara, R. Funakoshi, K. Gomberoff, Jeffrey Scott Hangst, R. Hayano, M.J. Jenkins, L. V. Jørgensen, P. Ko, N. Madsen, Paul J. Nolan, Robert D. Page, Lawrence Gene C. Posada, Alexander P. Povilus, E. Sarid, Daniel Miranda Silveira, Dirk Peter van der Werf, Y. Yamazaki, B. Parker, J. Escallier, A. Ghosh

Published Aug 3, 2006• 65 citations
Publisher
DOI
10.1016/j.nima.2006.07.012

Related papers

Towards antihydrogen confinement with the ALPHA antihydrogen trap

M. Fujiwara, David Russell Gill, L. L. Kurchaninov +32 more

Springer eBooks•Jan 1, 2007•1 citation

Towards antihydrogen confinement with the ALPHA antihydrogen trap

M. Fujiwara, Gorm Bruun Andresen, William Alan Bertsche +32 more

arXiv:0704.3320•Hyperfine Interactions•Sep 1, 2006•3 citations

Confinement of electrons and ions in a combined trap with the potential for antihydrogen production

J. Walz, S. B. Ross, Claus Zimmermann +3 more

Hyperfine Interactions•Dec 1, 1996•4 citations

Lifetime of magnetically trapped antihydrogen in ALPHA

A. Capra

arXiv:2005.03805•Hyperfine Interactions•Jan 7, 2019•10 citations

First Attempts at Antihydrogen Trapping in ALPHA

Gorm Bruun Andresen, William Alan Bertsche, Paul David Bowe +37 more

The ALPHA apparatus is designed to produce and trap antihydrogen atoms. The device comprises a multifunction Penning trap and a superconducting, neutral atom trap having a minimum‐B configuration. The atom trap features an octupole magnet for transverse confinement and solenoidal mirror coils for longitudinal confinement. The magnetic trap employs a fast shutdown system to maximize the probability of detecting the annihilation of released antihydrogen. In this article we describe the first attempts to observe antihydrogen trapping.

AIP conference proceedings•Jan 1, 2008•4 citations

Probing Trapped Antihydrogen. In Situ Diagnostics and Observations of Quantum Transitions

Tim Friesen

Antihydrogen, the bound state of a positron and an antiproton, is the simplest pure anti-atomic system and an excellent candidate to test the symmetry between matter and antimatter. This thesis focuses on the magnetic confinement of antihydrogen and the first ever resonant interaction with trapped antihydrogen, as performed by the ALPHA collaboration. The ALPHA apparatus and the techniques that have been developed to form, trap, probe, and detect antihydrogen atoms will be described in detail. The first successful demonstration of trapped antihydrogen will then be described. In the initial demonstrations, 38 trapped antihydrogen atoms were detected after being confined for at least 172 ms. Since then, over 400 antihydrogen atoms have been trapped and confinement times of 1000 s (over 15 minutes) have been demonstrated. Spectroscopy of these trapped antihydrogen atoms is the next major step forward. As an initial proof-of-principle demonstration, ALPHA induced and observed reso- nant positron spin flip (PSR) transitions between the ground states of antihydrogen. Because of the strong magnetic field dependence of these transition frequencies, the success of this experiment relied heavily on the ability to measure the magnetic field seen by the antihydrogen atoms. A novel method to measure the magnetic field in situ by detecting the cyclotron resonance of a trapped electron plasma is presented. This method allowed ALPHA to measure the magnetic field strength at the minimum of the magnetic antihydrogen trap to within 1.4 parts in 103. Hardware improvements and further study should allow this resolution to be improved by several orders of magnitude. The cyclotron resonance measurements can also be applied as a roughdiagnostic of a microwave field within the ALPHA apparatus. This allowed for important diagnostics of the microwave field used to excite the PSR transitions. Finally, the experimental results demonstrating resonant PSR transitions in antihydrogen are presented. This experiment is the first ever spectroscopic measurement of antihydrogen and an important step towards future precision spectroscopy.

•Jan 31, 2014•1 citation
The ALPHA apparatus is designed to produce and trap antihydrogen atoms. The device comprises a multifunction Penning trap and a superconducting, neutral atom trap having a minimum‐B configuration. The atom trap features an octupole magnet for transverse confinement and solenoidal mirror coils for longitudinal confinement. The magnetic trap employs a fast shutdown system to maximize the probability of detecting the annihilation of released antihydrogen. In this article we describe the first attempts to observe antihydrogen trapping.
Antihydrogen, the bound state of a positron and an antiproton, is the simplest pure anti-atomic system and an excellent candidate to test the symmetry between matter and antimatter. This thesis focuses on the magnetic confinement of antihydrogen and the first ever resonant interaction with trapped antihydrogen, as performed by the ALPHA collaboration. The ALPHA apparatus and the techniques that have been developed to form, trap, probe, and detect antihydrogen atoms will be described in detail. The first successful demonstration of trapped antihydrogen will then be described. In the initial demonstrations, 38 trapped antihydrogen atoms were detected after being confined for at least 172 ms. Since then, over 400 antihydrogen atoms have been trapped and confinement times of 1000 s (over 15 minutes) have been demonstrated. Spectroscopy of these trapped antihydrogen atoms is the next major step forward. As an initial proof-of-principle demonstration, ALPHA induced and observed reso- nant positron spin flip (PSR) transitions between the ground states of antihydrogen. Because of the strong magnetic field dependence of these transition frequencies, the success of this experiment relied heavily on the ability to measure the magnetic field seen by the antihydrogen atoms. A novel method to measure the magnetic field in situ by detecting the cyclotron resonance of a trapped electron plasma is presented. This method allowed ALPHA to measure the magnetic field strength at the minimum of the magnetic antihydrogen trap to within 1.4 parts in 103. Hardware improvements and further study should allow this resolution to be improved by several orders of magnitude. The cyclotron resonance measurements can also be applied as a roughdiagnostic of a microwave field within the ALPHA apparatus. This allowed for important diagnostics of the microwave field used to excite the PSR transitions. Finally, the experimental results demonstrating resonant PSR transitions in antihydrogen are presented. This experiment is the first ever spectroscopic measurement of antihydrogen and an important step towards future precision spectroscopy.