We discuss the minimization of the Dick effect in an optical lattice clock. We show that optimizing the time sequence of operation of the clock can lead to a significant reduction of the clock stability degradation by the frequency noise of the interrogation laser. By using a nondestructive detection of the atoms, we are able to recycle most of the atoms between cycles and consequently to strongly reduce the time spent capturing the atoms in each cycle. With optimized parameters, we expect a fractional Allan deviation better than 2 x 10(-16tau-1/2) for the lattice clock.
We present an analysis of the frequency stability degradation of an optical atomic frequency standard which is operated sequentially, and that is caused by the frequency noise of the laser used to interrogate the clock transition. This is an extension to optical frequencies of the 'Dick effect' already studied in atomic microwave frequency standards. It is shown that the simple concept of laser linewidth is not the relevant parameter to estimate the frequency stability degradation. Rather, the details of the laser frequency noise spectral density must be accounted for together with the parameters of the interrogation method. We compute the optical Dick effect in the case of a four pulse Ramsey–Bordé interferometer. We show that it may be minimized by optimizing the time sequence so that only the Fourier frequencies with minimum laser noise are sampled. Finally, we evaluate the degradation which would be obtained with one of our lasers used as an interrogation oscillator. This laser reaches a white noise floor S ν ( f ) = 10 −2 Hz 2 /Hz at a Fourier frequency of 100 Hz. We show that with this particular laser, a relative frequency stability of the order of 10 −16 in a 1 s averaging time can be reached using realistic experimental parameters.
Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.
We describe a method of duty cycle engineering in optical lattice clocks to reduce clock instability through tailoring of the Dick effect noise contribution. We apply dynamically decoupled interrogation sequences to realise an estimated improvement in single clock instability approaching a factor of two, as well as providing a route to zero dead-time operation for two interleaved clocks which are otherwise unable to reach the required duty cycle. We show through simulations and synchronous measurements of clocks NPL-Sr1 and NPL-Sr2 that a quantum projection noise limited instability < 3 − 10−17 τ −1/2 can be realised in a near ideal zero dead-time configuration.
The Dick effect is one of the main limits to the frequency stability of a passive frequency standard, especially for the fountain clock and ion clock operated in pulsed mode which require unavoidable dead time during interrogation. Here we measure the phase noise of the interrogation oscillator applied in the microwave frequency standard based on laser-cooled 113 Cd + ions, and analyze the Allan deviation limited by the Dick effect. The results indicate that the Dick effect is one of the key issues for the cadmium ion clock to reach expected frequency stability. This problem can be resolved by interrogating the local oscillator continuously with two ion traps.
Dick noise, arising from aliasing of local-oscillator (LO) fluctuations through dead time, limits the stability of leading optical lattice clocks. We propose a multiple-excitation protocol that implements coherence buffering: Most atoms are shelved in protected Zeeman manifolds, and controlled deexcitation releases fresh subensembles for sequential clock-transition interrogations within a single preparation. This timelike multiplexing raises the effective duty cycle without lengthening the interrogation beyond the coherence limit or shortening the fixed dead time. Sensitivity-function analysis shows a train of lobes in time and suppression of low-order Fourier components ${g}^{\ensuremath{'}}(m)$ that couple most strongly to LO flicker (
1/f) noise. Incorporating the quantum projection noise--limited atom number, coherence limited
Ti, and reservoir loss, we find a nonmonotonic optimum in the achievable interrogation count versus LO stability; for representative flicker levels ${\ensuremath{\sigma}}_{0}\ensuremath{\in}[4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16},8\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}]$, the Dick-noise contribution is reduced by approximately
2.4−−5.65dB. Time-domain Monte Carlo simulations using synthesized
1/f noise agree with the analytical predictions, and a noise decomposition based on experimentally reported power-law LO-noise parameters shows a nearly constant flicker fraction (approximately equal to
0.89) across interrogation numbers. More broadly, shelving-deexcitation coherence buffering is a portable ``prepare once, interrogate many'' primitive for quantum sensors, simulators, and processors.