Commissioning of the cryogenic plant for the cryogenic storage ring (CSR) at Heidelberg

R. von Hahn, M. Froese, M. Grieser, Ch. Haberstroh, D. Kaiser, Michael Lange, Felix Laux, S. Menk, D. A. Orlov, R. Repnow, Thomas Jrg Sieber, Hans H. Quack, Jozef Varju, A. Wolf

Published Jan 1, 2009• 0 citations
OpenAlex

Abstract

At the Max-Planck-Institute for Nuclear Physics in Heidelberg a next generation electrostatic storage ring for low velocity atomic and molecular ion beams is under construction. In contrast to existing electrostatic storage rings, the Cryogenic Storage Ring CSR will be cooled down to temperatures below 2 K. Thus acting as a large cryopump it will provide long storage times and, in addition, open a new field of quantum state controlled molecular physics due to a low heat radiation background from space-like environment. A concept for cooling the storage ring has been developed and is presently tested by means of a linear trap as a prototype with a length of 1/10 of the planned ring. A commercial refrigerator with 21 W at 2 K has been successfully commissioned and was connected to the prototype. This paper presents the status of the cryogenic plant after the commissioning and one year of operation.

Related papers

A cryogenic electrostatic storage ring project at RIKEN

Yuji Nakano, W Morimoto, T. Majima +4 more

A new, compact electrostatic storage ring for atomic and molecular physics is planned to be built at RIKEN, Japan. The new ring will be cooled down below 10 K to store rotationally cold molecular ions for a long period.

Journal of Physics Conference Series•Nov 5, 2012•20 citations

Coulomb crystals in a cryogenic Paul trap for sympathetic cooling of molecular ions and highly charged ions

A. Windberger, M. Schwarz, Oscar O. Versolato +11 more

Electron beam ion traps used for spectroscopy of highly charged ions (HCI) produce a deep trapping potential leading to high temperatures of the stored ions, and thus limiting the achievable spectral resolution. A novel device at the Max-Planck-Institut für Kernphysik, the Cryogenic linear Paul Trap Experiment (CryPTEx), attached to an electron beam ion trap, provides a new experimental platform to overcome these limitations. The trap assembly operates at a temperature of 4 K and offers optical access for quantum manipulation and imaging of the trapped ions. Since forbidden optical transitions in HCI do not support direct laser cooling, sympathetic cooling with Coulomb crystals of singly charged ions such as Be+ or Mg+ will be applied in order to reach the natural linewidth of optical forbidden transitions in HCI of interest. With the added advantage of long ion trapping times resulting from residual gas pressures of H2 at 4 K below 10−15 mbar, CryPTEx has been commissioned in collaboration with the Ion Trap Group in Århus using rovibrationally cooled MgH+ ions. Strong suppression of the black body radiation at the trap center, ion storage times of about 28 hours, and largely enhanced population of the rovibrational ground state were achieved.

AIP conference proceedings•Jan 1, 2013•4 citations

Precision Lifetime Measurements of He− in a Cryogenic Electrostatic Ion-Beam Trap

P. Reinhed, Andrea Orbán, J.G. Werner +9 more

We have developed a small purely electrostatic ion-beam trap which may be operated in thermal equilibrium at precisely controlled temperatures down to 10 K. Thus, we avoid magnetic field induced mixing of quantum states and may effectively eliminate any influence from absorption of photons from blackbody radiation. We report the first correction-free measurement of the lifetime of the 1s2s2p {4}P{5/2}{0} level of 4He(-) yielding the high-precision result 359.0 +/- 0.7 micros. This result is an essential proof-of-principle for cryogenic electrostatic storage rings and traps for atomic and molecular physics.

Physical Review Letters•Nov 18, 2009•54 citations

Ions in cold electrostatic storage devices

P. Reinhed

We have constructed a compact purely electrostatic ion-beam trap, ConeTrap, which we have mounted inside a double-walled vacuum chamber. In the inner vacuum chamber, we can obtain ultra-high vacuum (UHV) conditions and reach thermal equilibrium at well controlled temperatures down to 10 K. The chamber was constructed partly with the purpose of making high-precision measurements in ConeTrap, but also as a test-chamber for testing components (such as the detector-assembly tested and described in this thesis and paper III) to be used in the DESIREE (Double ElectroStatic Ion Ring ExpEriment) facility. The latter is a double electrostatic ion storage-ring being constructed at Stockholm University, in which the conditions are meant to mimic the environment in the interstellar medium. The interaction between two oppositely charged ions at very low relative velocities (controlled collision energies down to 10 meV) may then be studied in a section of the storage device where the two ion beams merge. The lifetime of loosely bound electronic systems, for example He-, is, at room temperature (and even at much lower temperatures), significantly affected by photons from blackbody radiation from the experimental device and its surroundings. The cryogenic temperature and low pressure obtained in the test chamber have made it possible to use ConeTrap to make the first correction-free lifetime measurement of the long-lived J=5/2 fine-structure level of the metastable 1s2s2p 4Po state of He-. Under the assumption of a statistical population of the fine-structure levels, at the time when the ions are created, we have also deduced the lifetimes of the short-lived J=1/2 and J=3/2 fine-structure levels. Furthermore, we have used ConeTrap to measure the pressure dependent storage lifetimes of He+ and Ar+ ions over wide ranges of temperatures and pressures, and we have thus been able to store positive ions with storage lifetimes of tens of seconds.

•Jan 1, 2010•1 citation

Cold ion beam in a storage ring as a platform for large-scale quantum computers and simulators: Challenges and directions for research and development

T. Shaftan, Boris B. Blinov

The purpose of this paper is to evaluate the possibility of constructing a large-scale storage-ring-type ion-trap system capable of storing, cooling, and controlling a large number of ions as a platform for scalable quantum computing (QC) and quantum simulations. In such a trap, the ions form a crystalline beam moving along a circular path with a constant velocity determined by the frequency and intensity of the cooling lasers. In this paper, we consider a large leap forward in terms of the number of ions that serve as qubits in QC, from fewer than 100 available in state of the art linear ion-trap devices today to an order of $1{0}^{5}$ crystallized ions in the storage-ring setup. This new trap design unifies two different concepts: the storage rings of charged particles and the linear ion traps used for QC and mass spectrometry. In this paper, we use the language of particle accelerators to discuss the ion state and dynamics. We outline the differences between the above concepts, analyze challenges of the large ring with a revolving chain of ions, and propose goals for the research and development required to enable future quantum computers with 1000 times more qubits than available today. The challenge of creating such a large-scale quantum system while maintaining the necessary coherence of the qubits and the high fidelity of quantum logic operations is significant. Performing analog quantum simulations may be an achievable initial goal for such a device. Quantum calculations and simulations of complex quantum systems will move forward both the fundamental science and the applied research. Nuclear and particle physics, many-body quantum systems, lattice gauge theories, and nuclear structure calculations are just a few examples in which a large-scale quantum simulation system will become a very powerful tool to move forward our understanding of nature.

arXiv:2101.04247•Physical Review Accelerators and Beams•Sep 13, 2021•3 citations

Cryogenic linear Paul trap for cold highly charged ion experiments

M. Schwarz, Oscar O. Versolato, A. Windberger +9 more

Storage and cooling of highly charged ions require ultra-high vacuum levels obtainable by means of cryogenic methods. We have developed a linear Paul trap operating at 4 K capable of very long ion storage times of about 30 h. A conservative upper bound of the H(2) partial pressure of about 10(-15) mbar (at 4 K) is obtained from this. External ion injection is possible and optimized optical access for lasers is provided, while exposure to black body radiation is minimized. First results of its operation with atomic and molecular ions are presented. An all-solid state laser system at 313 nm has been set up to provide cold Be(+) ions for sympathetic cooling of highly charged ions.

Review of Scientific Instruments•Aug 1, 2012•76 citations
At the Max-Planck-Institute for Nuclear Physics in Heidelberg a next generation electrostatic storage ring for low velocity atomic and molecular ion beams is under construction. In contrast to existing electrostatic storage rings, the Cryogenic Storage Ring CSR will be cooled down to temperatures below 2 K. Thus acting as a large cryopump it will provide long storage times and, in addition, open a new field of quantum state controlled molecular physics due to a low heat radiation background from space-like environment. A concept for cooling the storage ring has been developed and is presently tested by means of a linear trap as a prototype with a length of 1/10 of the planned ring. A commercial refrigerator with 21 W at 2 K has been successfully commissioned and was connected to the prototype. This paper presents the status of the cryogenic plant after the commissioning and one year of operation.
Electron beam ion traps used for spectroscopy of highly charged ions (HCI) produce a deep trapping potential leading to high temperatures of the stored ions, and thus limiting the achievable spectral resolution. A novel device at the Max-Planck-Institut für Kernphysik, the Cryogenic linear Paul Trap Experiment (CryPTEx), attached to an electron beam ion trap, provides a new experimental platform to overcome these limitations. The trap assembly operates at a temperature of 4 K and offers optical access for quantum manipulation and imaging of the trapped ions. Since forbidden optical transitions in HCI do not support direct laser cooling, sympathetic cooling with Coulomb crystals of singly charged ions such as Be+ or Mg+ will be applied in order to reach the natural linewidth of optical forbidden transitions in HCI of interest. With the added advantage of long ion trapping times resulting from residual gas pressures of H2 at 4 K below 10−15 mbar, CryPTEx has been commissioned in collaboration with the Ion Trap Group in Århus using rovibrationally cooled MgH+ ions. Strong suppression of the black body radiation at the trap center, ion storage times of about 28 hours, and largely enhanced population of the rovibrational ground state were achieved.
We have developed a small purely electrostatic ion-beam trap which may be operated in thermal equilibrium at precisely controlled temperatures down to 10 K. Thus, we avoid magnetic field induced mixing of quantum states and may effectively eliminate any influence from absorption of photons from blackbody radiation. We report the first correction-free measurement of the lifetime of the 1s2s2p {4}P{5/2}{0} level of 4He(-) yielding the high-precision result 359.0 +/- 0.7 micros. This result is an essential proof-of-principle for cryogenic electrostatic storage rings and traps for atomic and molecular physics.
We have constructed a compact purely electrostatic ion-beam trap, ConeTrap, which we have mounted inside a double-walled vacuum chamber. In the inner vacuum chamber, we can obtain ultra-high vacuum (UHV) conditions and reach thermal equilibrium at well controlled temperatures down to 10 K. The chamber was constructed partly with the purpose of making high-precision measurements in ConeTrap, but also as a test-chamber for testing components (such as the detector-assembly tested and described in this thesis and paper III) to be used in the DESIREE (Double ElectroStatic Ion Ring ExpEriment) facility. The latter is a double electrostatic ion storage-ring being constructed at Stockholm University, in which the conditions are meant to mimic the environment in the interstellar medium. The interaction between two oppositely charged ions at very low relative velocities (controlled collision energies down to 10 meV) may then be studied in a section of the storage device where the two ion beams merge. The lifetime of loosely bound electronic systems, for example He-, is, at room temperature (and even at much lower temperatures), significantly affected by photons from blackbody radiation from the experimental device and its surroundings. The cryogenic temperature and low pressure obtained in the test chamber have made it possible to use ConeTrap to make the first correction-free lifetime measurement of the long-lived J=5/2 fine-structure level of the metastable 1s2s2p 4Po state of He-. Under the assumption of a statistical population of the fine-structure levels, at the time when the ions are created, we have also deduced the lifetimes of the short-lived J=1/2 and J=3/2 fine-structure levels. Furthermore, we have used ConeTrap to measure the pressure dependent storage lifetimes of He+ and Ar+ ions over wide ranges of temperatures and pressures, and we have thus been able to store positive ions with storage lifetimes of tens of seconds.
The purpose of this paper is to evaluate the possibility of constructing a large-scale storage-ring-type ion-trap system capable of storing, cooling, and controlling a large number of ions as a platform for scalable quantum computing (QC) and quantum simulations. In such a trap, the ions form a crystalline beam moving along a circular path with a constant velocity determined by the frequency and intensity of the cooling lasers. In this paper, we consider a large leap forward in terms of the number of ions that serve as qubits in QC, from fewer than 100 available in state of the art linear ion-trap devices today to an order of 1051{0}^{5}105 crystallized ions in the storage-ring setup. This new trap design unifies two different concepts: the storage rings of charged particles and the linear ion traps used for QC and mass spectrometry. In this paper, we use the language of particle accelerators to discuss the ion state and dynamics. We outline the differences between the above concepts, analyze challenges of the large ring with a revolving chain of ions, and propose goals for the research and development required to enable future quantum computers with 1000 times more qubits than available today. The challenge of creating such a large-scale quantum system while maintaining the necessary coherence of the qubits and the high fidelity of quantum logic operations is significant. Performing analog quantum simulations may be an achievable initial goal for such a device. Quantum calculations and simulations of complex quantum systems will move forward both the fundamental science and the applied research. Nuclear and particle physics, many-body quantum systems, lattice gauge theories, and nuclear structure calculations are just a few examples in which a large-scale quantum simulation system will become a very powerful tool to move forward our understanding of nature.
Storage and cooling of highly charged ions require ultra-high vacuum levels obtainable by means of cryogenic methods. We have developed a linear Paul trap operating at 4 K capable of very long ion storage times of about 30 h. A conservative upper bound of the H(2) partial pressure of about 10(-15) mbar (at 4 K) is obtained from this. External ion injection is possible and optimized optical access for lasers is provided, while exposure to black body radiation is minimized. First results of its operation with atomic and molecular ions are presented. An all-solid state laser system at 313 nm has been set up to provide cold Be(+) ions for sympathetic cooling of highly charged ions.