Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Magnetics

Fabrication and performance of high T/sub c/ two hole bulk and single hole thick film RF SQUIDs at 77 K

Neeraj Khare, Anurag Gupta, Sangeeta Chaudhry, Sunil Kumar Arora, V S Tomar, Vijay Narain Ojha

Published Mar 1, 1991• 5 citations
Publisher

Abstract

Two-hole YBCO bulk and one-hole YBCO, BSCCO thick-film RF SQUIDs have been fabricated and operated at 77 K. RF SQUID behavior has been studied using commercial RF SQUID electronics with external RF and AF sources. Flux noise density of these SQUIDs depends on the quality of the microbridge. Flux noise present in various reported high-T/sub c/ film RF SQUIDs is compared.

DOI
10.1109/20.133848

Related papers

Noise measurements in a 2-hole radio frequency SQUID at liquid nitrogen temperature

S.P. Harrop, M. S. Colclough, Colin E Gough +2 more

The authors report measurements of the noise in a two-hole RF SQUID (superconducting quantum interference device) fabricated from bulk YBCO by an erosion technique in the frequency range 30 mHz to 1 kHz. Above 100 Hz the noise is essentially white with an RMS (root mean square) value of 5*10/sup -4/ phi /sub 0// square root Hz and is dominated by noise from the electronics. Below 10-Hz the noise power rises as 1/f/sup 0/9/.>

IEEE Transactions on Magnetics•Mar 1, 1989•2 citations

Substrate step-edge YBa2Cu3O7 rf SQUIDs

K.P. Daly, William D. Dozier, John F. Burch +4 more

We have developed a technique which permits high-yield fabrication of microbridges and low noise YBa2Cu3O7 superconducting quantum interference devices (SQUIDs) in epitaxial thin films. These SQUIDs operate over a wide temperature range extending from 4 K to close to the superconducting transition temperature. Measurements of an rf SQUID operating at 77 K give a peak-to-peak flux sensitivity of 36 μV/Φ0 and a flux noise at 10 Hz of 1.5× 10−4 Φ0/√Hz. Device yields over 80% have been obtained.

Applied Physics Letters•Feb 4, 1991•140 citations

Fabrication and measurement of cylindrical Nb3Ge rf SQUIDs

Shinya Kuriki, M. Suehiro, Hajime Konishi

Nb3Ge thin-film microbridges are fabricated on a cylindrical substrate to form rf SQUIDs. High temperature operations well above 10 K (up to 17.5 K) are obtained. An intrinsic flux noise of the order of 10−4 Φ0/(Hz)1/2 is estimated from the step rise parameter. Comparison with a theoretical noise indicates a nonsinusoidal current phase relation of the microbridge.

Journal of Applied Physics•Mar 1, 1985•3 citations

rf break-junction SQUID’s at 77 K

I K Harvey, R.A. Binks, R. Driver

Break-junction rf superconducting quantum interference devices (SQUID’s) have been developed using bulk YBa2Cu3O7 ceramic samples which have been fabricated in the laboratory. The SQUID’s have been produced in both single, and two-hole topologies and their noise characteristics have been measured at 77 K. The equivalent flux noise of the two-hole SQUID at a frequency of 200 Hz was found to be 6.8×10−4 flux quantum/(Hz)1/2.

Applied Physics Letters•May 9, 1988•14 citations

Noise measurements in a two-hole radio frequency SQUID at liquid-nitrogen temperature

S.P. Harrop, Colin E Gough, Mark N. Keene +1 more

The authors report measurements of the noise in a two-hole RF SQUID fabricated from YBCO by an erosion technique. The noise was measured from 10 mHz to 1 kHz. Above 25 Hz the noise is essentially white with an RMS value of 1.3*10 -3 phi 0 Hz -1/2 and is dominated by the noise of the amplifier. Below 1 Hz the noise power rises as 1/f 1.3 .

Superconductor Science and Technology•Aug 1, 1988•11 citations

High- T c radio-frequency superconducting quantum interference devices fabricated from YBa 2 Cu 3 O 7-δ using focused helium ion beam technique

Ziwen 紫雯 Chen 陈, Yulong Li, Yan Zhang +3 more

The reliable fabrication of high-sensitivity superconducting quantum interference devices (SQUIDs) with high critical transition temperature (high- T c ) is crucial for many practical applications such as weak magnetic sensing. In this work, we report the first realization of the YBa 2 Cu 3 O 7− δ (YBCO) radio frequency SQUIDs (rf SQUIDs) based on focused helium ion beam (FHIB) technique. A series of YBCO rf SQUIDs with high consistency were fabricated using a 30 keV FHIB with different helium ion (He + ) dose. The dose-dependent characteristics of the fabricated devices were systematically investigated at a temperature of 77 K. The experimental results verify that the variation in He + dose can effectively modulate the junction parameters and thereby the device noise performance. A non-monotonic white noise trend with increasing He + dose was observed, which could be primarily attributed to the transition of operational working regime of the fabricated rf SQUIDs. Based upon the dose optimization, a flux noise of 58 μ Φ 0 / H z 1 / 2 , corresponding to a field sensitivity of 185 f T / H z 1 / 2 , was achieved with our current device configuration. Approaches to further optimize the overall device performance are also discussed. Our work demonstrates FHIB-based high- T c SQUIDs with high junction parameter consistency a promising candidate for the implementation of multi-channel weak magnetic field detection systems and might hopefully serve as a platform for validating the theoretical models of high- T c SQUIDs.

Superconductor Science and Technology•Oct 1, 2026•0 citations
Two-hole YBCO bulk and one-hole YBCO, BSCCO thick-film RF SQUIDs have been fabricated and operated at 77 K. RF SQUID behavior has been studied using commercial RF SQUID electronics with external RF and AF sources. Flux noise density of these SQUIDs depends on the quality of the microbridge. Flux noise present in various reported high-T/sub c/ film RF SQUIDs is compared.
We have developed a technique which permits high-yield fabrication of microbridges and low noise YBa2Cu3O7 superconducting quantum interference devices (SQUIDs) in epitaxial thin films. These SQUIDs operate over a wide temperature range extending from 4 K to close to the superconducting transition temperature. Measurements of an rf SQUID operating at 77 K give a peak-to-peak flux sensitivity of 36 μV/Φ0 and a flux noise at 10 Hz of 1.5× 10−4 Φ0/√Hz. Device yields over 80% have been obtained.
The reliable fabrication of high-sensitivity superconducting quantum interference devices (SQUIDs) with high critical transition temperature (high- T c ) is crucial for many practical applications such as weak magnetic sensing. In this work, we report the first realization of the YBa 2 Cu 3 O 7− δ (YBCO) radio frequency SQUIDs (rf SQUIDs) based on focused helium ion beam (FHIB) technique. A series of YBCO rf SQUIDs with high consistency were fabricated using a 30 keV FHIB with different helium ion (He + ) dose. The dose-dependent characteristics of the fabricated devices were systematically investigated at a temperature of 77 K. The experimental results verify that the variation in He + dose can effectively modulate the junction parameters and thereby the device noise performance. A non-monotonic white noise trend with increasing He + dose was observed, which could be primarily attributed to the transition of operational working regime of the fabricated rf SQUIDs. Based upon the dose optimization, a flux noise of 58 μ Φ 0 / H z 1 / 2 , corresponding to a field sensitivity of 185 f T / H z 1 / 2 , was achieved with our current device configuration. Approaches to further optimize the overall device performance are also discussed. Our work demonstrates FHIB-based high- T c SQUIDs with high junction parameter consistency a promising candidate for the implementation of multi-channel weak magnetic field detection systems and might hopefully serve as a platform for validating the theoretical models of high- T c SQUIDs.