Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physica Scripta

Simulations of Laser Cooling in a Penning Ion Trap

Richard Claude Thompson

Published Jan 1, 1988• 7 citations
Publisher

Abstract

We present the results of some simulations of the laser cooling process for a single ion in a Penning ion trap. The situation is rather more complicated than in an r.f. trap, due to the presence of the magnetron drift. We show that under some circumstances the ion can get into an orbit which is different from the usual one in the trap, and that in order to apply laser cooling in this case one has to use a different procedure from the conventional one. We also present heating and cooling curves for the ion as a function of laser frequency and as a function of time.

DOI
10.1088/0031-8949/1988/t22/052

Related papers

Laser cooling of ions stored in a Penning trap: A phase-space picture

G. Horváth, Richard Claude Thompson

We present a phase-space picture of laser cooling of the radial motion of ions in a Penning trap. This picture enables a particularly simple derivation of the condition for simultaneous cooling of all degrees of freedom of a single ion to be obtained. It also allows a physically intuitive approach to be taken to the cooling process. Using this approach, we discuss different aspects of the cooling of a single ion in a Penning trap, including the formation of ``trapped'' states where the steady-state motion amplitude is nonzero for either the magnetron or modified cyclotron motion. We use an analytical approach where the approximation of small-amplitude motions can be made, and we use numerical calculations for larger-amplitude motions. The best procedure to use for effective laser cooling is derived. A similar approach is then used to treat the laser cooling of two ions in the Penning trap. We show that the use of the phase-space approach allows new insights into many aspects of the laser-cooling process to be gained, and we indicate how these insights may be applied in experimental investigations.

Physical Review A•Jun 1, 1999•7 citations

Simple model for the laser cooling of an ion in a Penning trap

Richard Claude Thompson, J Papadimitriou

We present a model for laser cooling of a single ion in the Penning trap. The model solves the equations of motion in the presence of the damping caused by the interaction with the laser beam, and predicts for the first time the dependence of the cooling rates for the two radial degrees of freedom in the trap as a function of the laser detuning, laser beam offset and saturation parameter. The conditions derived for both radial degrees of freedom to be cooled simultaneously agree with those found in earlier studies. The results indicate that under conditions where both motions are cooled simultaneously, the cooling rates are both significantly smaller than the maximum rate for either motion considered in isolation. Furthermore, the magnetron cooling rate is typically much lower than the cyclotron cooling rate, as has been found in experiments. The model indicates how the cooling rate for a single ion may be optimized.

Journal of Physics B Atomic Molecular and Optical Physics•Aug 23, 2000•20 citations

Improvement of Laser Cooling of Ions in a Penning Trap by use of the Axialisation Technique

Powell, H. F., S.R. de Echaniz, E. S. Phillips +2 more

We report a study of the axialisation and laser cooling of single ions and small clouds of ions in a Penning trap. A weak radiofrequency signal applied to a segmented ring electrode couples the magnetron motion to the cyclotron motion, which results in improved laser cooling of the magnetron motion. This allows us to approach the trapping conditions of a Paul trap, but without any micromotion. Using an ICCD camera we show that the motion of a single ion can be confined to dimensions of the order of 10 $μ$m. We have measured increased magnetron cooling rates using an rf-photon correlation technique. For certain laser cooling conditions, the magnetron motion of the centre of mass of the cloud grows and stabilises at a large value. This results in the ions orbiting the centre of the trap together in a small cloud, as confirmed by photon-photon correlation measurements.

arXiv:quant-ph/0211016•Nov 5, 2002•1 citation

Improvement of laser cooling of ions in a Penning trap by use of the axialization technique

Hebe Powell, S.R. de Echaniz, E. S. Phillips +2 more

We report a study of the axialization and laser cooling of single ions and small clouds of ions in a Penning trap. A weak radiofrequency (rf) signal applied to a segmented ring electrode couples the magnetron motion to the cyclotron motion, which results in improved laser cooling of the magnetron motion. This allows us to approach the trapping conditions of a Paul trap, but without any micromotion. Using an ICCD camera we show that the motion of a single ion can be confined to dimensions of the order of 20 µm or less. We have measured increased magnetron cooling rates for clouds of a few ions, using an rf-photon correlation technique. For certain laser cooling conditions, the magnetron motion of the centre of mass of the cloud grows and stabilizes at a large value. This results in the ions orbiting the centre of the trap together in a small cloud, as confirmed by photon–photon correlation measurements.

Journal of Physics B Atomic Molecular and Optical Physics•Feb 24, 2003•10 citations

Laser cooling in the Penning trap: an analytical model for cooling rates in the presence of an axializing field

Richard Hendricks, E. S. Phillips, D. M. Segal +1 more

Ions stored in Penning traps may have useful applications in the field of quantum information processing. There are, however, difficulties associated with the laser cooling of one of the radial motions of ions in these traps, namely the magnetron motion. The application of a small radio-frequency quadrupolar electric potential resonant with the sum of the two radial motional frequencies has been shown to couple these motions and to lead to more efficient laser cooling. We present an analytical model that enables us to determine laser cooling rates in the presence of such an ‘axializing’ field. It is found that this field leads to an averaging of the laser cooling rates for the two motions and hence improves the overall laser cooling efficiency. The model also predicts shifts in the motional frequencies due to the axializing field that are in qualitative agreement with those measured in recent experiments. It is possible to determine laser cooling rates experimentally by studying the phase response of the cooled ions to a near resonant excitation field. Using the model developed in this paper, we study the expected phase response when an axializing field is present.

arXiv:0709.3817•Journal of Physics B Atomic Molecular and Optical Physics•Jan 22, 2008•14 citations

Laser-cooling limits and single-ion spectroscopy

David J. Wineland, Wayne M. Itano, Jonas Bergquist +1 more

The limitations to the achievement of low kinetic energies for laser cooling of single ions confined in electromagnetic traps are discussed. Sideband cooling of an ion in an rf (Paul) trap is reexamined including the effects of finite laser bandwidth and the energy of the rf micromotion. The micromotion is the oscillatory motion of the ion at the same frequency as the rf voltage applied to the trap electrodes. Sideband cooling of ions in a Penning trap is examined for the first time. In both cases, cooling to the zero-point energy of the ion in the trap should be possible and a method for verifying this condition is suggested. The implications for high-resolution, high-accuracy spectroscopy are investigated. Under certain conditions, the uncertainty in the second-order Doppler shift may be significantly less than 1 part in ${10}^{18}$. .AE

Physical Review A•Sep 1, 1987•165 citations
We present the results of some simulations of the laser cooling process for a single ion in a Penning ion trap. The situation is rather more complicated than in an r.f. trap, due to the presence of the magnetron drift. We show that under some circumstances the ion can get into an orbit which is different from the usual one in the trap, and that in order to apply laser cooling in this case one has to use a different procedure from the conventional one. We also present heating and cooling curves for the ion as a function of laser frequency and as a function of time.
We present a phase-space picture of laser cooling of the radial motion of ions in a Penning trap. This picture enables a particularly simple derivation of the condition for simultaneous cooling of all degrees of freedom of a single ion to be obtained. It also allows a physically intuitive approach to be taken to the cooling process. Using this approach, we discuss different aspects of the cooling of a single ion in a Penning trap, including the formation of ``trapped'' states where the steady-state motion amplitude is nonzero for either the magnetron or modified cyclotron motion. We use an analytical approach where the approximation of small-amplitude motions can be made, and we use numerical calculations for larger-amplitude motions. The best procedure to use for effective laser cooling is derived. A similar approach is then used to treat the laser cooling of two ions in the Penning trap. We show that the use of the phase-space approach allows new insights into many aspects of the laser-cooling process to be gained, and we indicate how these insights may be applied in experimental investigations.
We present a model for laser cooling of a single ion in the Penning trap. The model solves the equations of motion in the presence of the damping caused by the interaction with the laser beam, and predicts for the first time the dependence of the cooling rates for the two radial degrees of freedom in the trap as a function of the laser detuning, laser beam offset and saturation parameter. The conditions derived for both radial degrees of freedom to be cooled simultaneously agree with those found in earlier studies. The results indicate that under conditions where both motions are cooled simultaneously, the cooling rates are both significantly smaller than the maximum rate for either motion considered in isolation. Furthermore, the magnetron cooling rate is typically much lower than the cyclotron cooling rate, as has been found in experiments. The model indicates how the cooling rate for a single ion may be optimized.
We report a study of the axialisation and laser cooling of single ions and small clouds of ions in a Penning trap. A weak radiofrequency signal applied to a segmented ring electrode couples the magnetron motion to the cyclotron motion, which results in improved laser cooling of the magnetron motion. This allows us to approach the trapping conditions of a Paul trap, but without any micromotion. Using an ICCD camera we show that the motion of a single ion can be confined to dimensions of the order of 10 μμμm. We have measured increased magnetron cooling rates using an rf-photon correlation technique. For certain laser cooling conditions, the magnetron motion of the centre of mass of the cloud grows and stabilises at a large value. This results in the ions orbiting the centre of the trap together in a small cloud, as confirmed by photon-photon correlation measurements.
We report a study of the axialization and laser cooling of single ions and small clouds of ions in a Penning trap. A weak radiofrequency (rf) signal applied to a segmented ring electrode couples the magnetron motion to the cyclotron motion, which results in improved laser cooling of the magnetron motion. This allows us to approach the trapping conditions of a Paul trap, but without any micromotion. Using an ICCD camera we show that the motion of a single ion can be confined to dimensions of the order of 20 µm or less. We have measured increased magnetron cooling rates for clouds of a few ions, using an rf-photon correlation technique. For certain laser cooling conditions, the magnetron motion of the centre of mass of the cloud grows and stabilizes at a large value. This results in the ions orbiting the centre of the trap together in a small cloud, as confirmed by photon–photon correlation measurements.
Ions stored in Penning traps may have useful applications in the field of quantum information processing. There are, however, difficulties associated with the laser cooling of one of the radial motions of ions in these traps, namely the magnetron motion. The application of a small radio-frequency quadrupolar electric potential resonant with the sum of the two radial motional frequencies has been shown to couple these motions and to lead to more efficient laser cooling. We present an analytical model that enables us to determine laser cooling rates in the presence of such an ‘axializing’ field. It is found that this field leads to an averaging of the laser cooling rates for the two motions and hence improves the overall laser cooling efficiency. The model also predicts shifts in the motional frequencies due to the axializing field that are in qualitative agreement with those measured in recent experiments. It is possible to determine laser cooling rates experimentally by studying the phase response of the cooled ions to a near resonant excitation field. Using the model developed in this paper, we study the expected phase response when an axializing field is present.
The limitations to the achievement of low kinetic energies for laser cooling of single ions confined in electromagnetic traps are discussed. Sideband cooling of an ion in an rf (Paul) trap is reexamined including the effects of finite laser bandwidth and the energy of the rf micromotion. The micromotion is the oscillatory motion of the ion at the same frequency as the rf voltage applied to the trap electrodes. Sideband cooling of ions in a Penning trap is examined for the first time. In both cases, cooling to the zero-point energy of the ion in the trap should be possible and a method for verifying this condition is suggested. The implications for high-resolution, high-accuracy spectroscopy are investigated. Under certain conditions, the uncertainty in the second-order Doppler shift may be significantly less than 1 part in 1018{10}^{18}1018. .AE